It is well known that the fair-sampling loophole in Bell test opened by the selection of the state to be measured can lead to post-quantum correlations. In this paper, we make the selection of the results after measurement, which opens the fair- sampling loophole too, and thus can lead to post-quantum correlations. This kind of result-selection loophole can be realized by pre- and post-selection processes within the "two-state vector formalism", and a physical simulation of Popescu-Rohrlich (PR) box is designed in linear optical system. The probability distribution of the PR has a maximal CHSH value 4, i.e. it can maximally violate CHSH inequality. Because the "two-state vector formalism" violates the information causality, it opens the locality loophole too, which means that this kind of results selection within "two-state vector formalism" leads to both fair- sampling loophole and locality loophole, so we call it a comprehensive loophole in Bell test. The comprehensive loophole opened by the results selection within "two-state vector formalism" may be another possible explanation of why post-quantum correlations are incompatible with quantum mechanics and seem not to exist in nature.Entities:
Year: 2016 PMID: 27329203 PMCID: PMC4916437 DOI: 10.1038/srep28351
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1The optical simulation of a PR box.
BBO1 is a nonlinear crystal (beta-barium borate), and BBO2 is half the thickness of BBO1. M is a mirror, HWP denotes a half wave plate. PBSi (i = 1, 2, 3, 5, 6, 7) denotes a general polarizing beam splitter, which transmits horizontally polarized photons and reflects vertically polarized photons. PBS4 is a rotated polarizing beam splitter, which transmits the photons in state and reflects the photons in state . D1, D2, D3, D4, D5, D6 are single-photon detectors. Sapphire laser were frequency doubled (*2) to provide UV pulses , which are used to pump BBO1 crystal. The results are registered through a three-port coincidence circuit (D2, D3 and D5) with a coincidence window.
Figure 2The schematic diagram of the observables of Alice and Bob.
The angle settings of HWPs.
| HWP4 (10) | HWP5 (11) | HWP6 (8) | HWP7 (9) | |
|---|---|---|---|---|
| 0° | 22.5° | 0° | 0° | |
| 0° | 22.5° | 0° | 45° | |
| 0° | 22.5° | 45° | 0° | |
| 0° | 22.5° | 45° | 45° | |
| 0° | 0° | 0° | 0° | |
| 0° | 0° | 0° | 45° | |
| 0° | 0° | 45° | 0° | |
| 0° | 0° | 45° | 45° | |
| 22.5° | 22.5° | 0° | 0° | |
| 22.5° | 22.5° | 0° | 45° | |
| 22.5° | 22.5° | 45° | 0° | |
| 22.5° | 22.5° | 45° | 45° | |
| 22.5° | 0° | 0° | 0° | |
| 22.5° | 0° | 0° | 45° | |
| 22.5° | 0° | 45° | 0° | |
| 22.5° | 0° | 45° | 45° |