Literature DB >> 27321963

Corrosion at the Head-Neck Junction: Why Is This Happening Now?

Joshua J Jacobs1.   

Abstract

While mechanically-assisted crevice corrosion (MACC) at the head/neck junction of modular total hip arthroplasty (THA) femoral components was first described over two decades ago, it is only within the last few years that investigators have observed that adverse local tissue reactions (ALTRs) associated with MACC are an increasingly prevalent mode of failure of contemporary THAs. As yet, the incidence, etiology and pathogenesis of MACC-associated ALTR are not well understood. In this review, possible implant-, patient-, and surgeon-related factors are considered in the context of a small but growing body of evidence from laboratory simulations, implant and tissue retrieval studies and clinical case series. It is likely that MACC-associated ALTR is a multifactorial process and that ongoing research will lead to multiple strategies that will facilitate early diagnosis and ultimately prevention of the adverse clinical sequelae of this phenomenon.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bearing surfaces; complications; corrosion; implant retrieval analysis; metal debris; primary hip arthroplasty

Mesh:

Substances:

Year:  2016        PMID: 27321963     DOI: 10.1016/j.arth.2016.03.029

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

Review 1.  What Factors Drive Taper Corrosion?

Authors:  Robin Pourzal; Hannah J Lundberg; Deborah J Hall; Joshua J Jacobs
Journal:  J Arthroplasty       Date:  2018-03-30       Impact factor: 4.757

2.  Do Well-functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion?

Authors:  Jeffrey Lange; Amanda Wach; Chelsea N Koch; Robert H Hopper; Henry Ho; Charles A Engh; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-10       Impact factor: 4.176

3.  CORR Insights®: Do Well-functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion?

Authors:  Ronald Emilio Delanois
Journal:  Clin Orthop Relat Res       Date:  2018-10       Impact factor: 4.176

4.  In Vitro Evidence for Cell-Accelerated Corrosion Within Modular Junctions of Total Hip Replacements.

Authors:  Divya Rani Bijukumar; Shruti Salunkhe; Dalton Morris; Abhijith Segu; Deborah J Hall; Robin Pourzal; Mathew T Mathew
Journal:  J Orthop Res       Date:  2019-09-01       Impact factor: 3.494

5.  Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study.

Authors:  Dmitry Royhman; Robin Pourzal; Deborah Hall; Hannah J Lundberg; Markus A Wimmer; Joshua Jacobs; Nadim J Hallab; Mathew T Mathew
Journal:  J Mech Behav Biomed Mater       Date:  2021-03-12

6.  Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship Than Other Designs: A Nationwide Cohort of 324,108 Patients.

Authors:  Sandrine Colas; Assia Allalou; Antoine Poichotte; Philippe Piriou; Rosemary Dray-Spira; Mahmoud Zureik
Journal:  Clin Orthop Relat Res       Date:  2017-02-13       Impact factor: 4.176

7.  Standardizing terms for tribocorrosion-associated adverse local tissue reaction in total hip arthroplasty.

Authors:  Brian J McGrory; Joshua J Jacobs; Young-Min Kwon; Yale Fillingham
Journal:  Arthroplast Today       Date:  2020-03-03

8.  Taper fretting corrosion with Stryker Anato stem after hip replacement.

Authors:  David M Freccero; Kenneth J McAlpine; Eric L Smith
Journal:  Arthroplast Today       Date:  2020-03-31

9.  Dual-taper modular hip implant: Investigation of 3-dimensional surface scans for component contact, shape, and fit.

Authors:  Nicholas B Frisch; Jonathan R Lynch; Robin Pourzal; Richard F Banglmaier; Craig D Silverton
Journal:  Arthroplast Today       Date:  2018-07-21

10.  A Case of Titanium Pseudotumor and Systemic Toxicity After Total Hip Arthroplasty Polyethylene Failure.

Authors:  Sandip P Tarpada; Jeremy Loloi; Evan M Schwechter
Journal:  Arthroplast Today       Date:  2020-08-27
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.