Heinz Deschka1, Alexander J Holthaus2, Jürgen R Sindermann2, Henryk Welp2, Dominik Schlarb3, Nadejda Monsefi4, Sven Martens2, Mirela Scherer2. 1. Department for Cardiothoracic Surgery, Division of Cardiac Surgery, University Hospital Münster, Münster, Germany. Electronic address: deschkaheinz@hotmail.com. 2. Department for Cardiothoracic Surgery, Division of Cardiac Surgery, University Hospital Münster, Münster, Germany. 3. Department for Plastic and Aesthetic Surgery, Fachklinik Hornheide, Münster, Germany. 4. Department for Thoracic and Cardiovascular Surgery, J.-W. Goethe Universität, Frankfurt/Main, Germany.
Abstract
OBJECTIVES: Depending on the pre-existing condition of the right ventricle (RV), left ventricular assist device (LVAD) implantation may have a detrimental effect on RV function, subsequently leading to right heart failure. This study details the authors' experience with perioperative mechanical RV support in patients with biventricular impairment but primarily scheduled for isolated LVAD implantation. DESIGN: Retrospective study. SETTING: Two center study, university hospital. PARTICIPANTS: This study included LVAD recipients with preoperative biventricular impairment who received an additional right ventricular assist device (RVAD) after a failed weaning attempt from cardiopulmonary bypass due to acute RV failure. INTERVENTIONS: Outcomes of 25 patients who underwent LVAD and unplanned temporary RVAD implantation were analyzed. MEASUREMENTS AND MAIN RESULTS: All patients experienced significant preoperative RV impairment (tricuspid annular plane systolic excursion: 10.2±26.3 mm; right atrium pressure: 17.9±10.4 mmHg) and pulmonary hypertension (pulmonary artery pressure: 54.8±25.7 mmHg). In 15 patients, additional tricuspid valve annuloplasty was performed. Mean duration of temporary RVAD support was 11.1±7.2 days. In 23 patients (92%), the RVAD was removed successfully. None of the patients developed RV failure after RVAD removal. Hospital survival and the 1-year survival rate of the study group were 68% and 56%, respectively. CONCLUSIONS: The results of perioperative RVAD support in LVAD recipients with biventricular dysfunction are encouraging. Temporary RVAD support allows an already compromised RV to become attuned to the hemodynamic conditions after LVAD implantation. This strategy provides patients with preoperative impaired RV function a high likelihood to permanently undergo LVAD support only.
OBJECTIVES: Depending on the pre-existing condition of the right ventricle (RV), left ventricular assist device (LVAD) implantation may have a detrimental effect on RV function, subsequently leading to right heart failure. This study details the authors' experience with perioperative mechanical RV support in patients with biventricular impairment but primarily scheduled for isolated LVAD implantation. DESIGN: Retrospective study. SETTING: Two center study, university hospital. PARTICIPANTS: This study included LVAD recipients with preoperative biventricular impairment who received an additional right ventricular assist device (RVAD) after a failed weaning attempt from cardiopulmonary bypass due to acute RV failure. INTERVENTIONS: Outcomes of 25 patients who underwent LVAD and unplanned temporary RVAD implantation were analyzed. MEASUREMENTS AND MAIN RESULTS: All patients experienced significant preoperative RV impairment (tricuspid annular plane systolic excursion: 10.2±26.3 mm; right atrium pressure: 17.9±10.4 mmHg) and pulmonary hypertension (pulmonary artery pressure: 54.8±25.7 mmHg). In 15 patients, additional tricuspid valve annuloplasty was performed. Mean duration of temporary RVAD support was 11.1±7.2 days. In 23 patients (92%), the RVAD was removed successfully. None of the patients developed RV failure after RVAD removal. Hospital survival and the 1-year survival rate of the study group were 68% and 56%, respectively. CONCLUSIONS: The results of perioperative RVAD support in LVAD recipients with biventricular dysfunction are encouraging. Temporary RVAD support allows an already compromised RV to become attuned to the hemodynamic conditions after LVAD implantation. This strategy provides patients with preoperative impaired RV function a high likelihood to permanently undergo LVAD support only.
Authors: Anthony E Peters; LaVone A Smith; Priscilla Ababio; Khadijah Breathett; Timothy L McMurry; Jamie L W Kennedy; Mohammad Abuannadi; James Bergin; Sula Mazimba Journal: J Card Fail Date: 2019-02-18 Impact factor: 5.712
Authors: Valeria Lo Coco; Maria Elena De Piero; Giulio Massimi; Giovanni Chiarini; Giuseppe M Raffa; Mariusz Kowalewski; Jos Maessen; Roberto Lorusso Journal: J Thorac Dis Date: 2021-02 Impact factor: 2.895