Literature DB >> 27313740

Optimal settings and accuracy of indocyanine green fluorescence imaging for sentinel node biopsy in early gastric cancer.

Shinichi Kinami1, Toshio Oonishi1, Jun Fujita1, Yasuto Tomita1, Hiroshi Funaki1, Hideto Fujita1, Yasuharu Nakano1, Nobuhiko Ueda1, Takeo Kosaka1.   

Abstract

Indocyanine green (ICG) fluorescence imaging represents a promising method for sentinel node (SN) biopsy in laparoscopic gastric surgery due to its signal stability. In the present study, the suitability and optimal settings of ICG fluorescence imaging for SN biopsy in early gastric cancer were determined. Patients with single primary superficial-type adenocarcinoma of the stomach, lesions <5 cm in diameter, and no evident nodal metastasis and out of indication for endoscopic submucosal dissection were enrolled. The day prior to surgery, ICG solution was endoscopically injected into four quadrants of the submucosal layer of the tumor. The Photodynamic Eye was used to detect ICG fluorescence. Bright nodes were defined as clearly fluorescent nodes. A total of 72 patients were enrolled; 11 cases presented with metastasis, and of these, 10 could be diagnosed by bright node biopsy. The adequate concentration and injection volume of ICG was determined to be 50 µg/ml (×100) and 0.5 mlx4 points, respectively. There was 1 false-negative case, and this was attributed to the failure of the frozen section diagnosis. These results suggested that ICG fluorescence imaging for SN biopsy in laparoscopic surgery for early gastric cancer is feasible. However, a weakness of ICG fluorescence imaging is the subjectivity of bright node evaluation.

Entities:  

Keywords:  fluorescence imaging; gastric cancer; indocyanine green; sentinel lymph node biopsy

Year:  2016        PMID: 27313740      PMCID: PMC4888277          DOI: 10.3892/ol.2016.4492

Source DB:  PubMed          Journal:  Oncol Lett        ISSN: 1792-1074            Impact factor:   2.967


  41 in total

1.  Mapping sentinel nodes in patients with early-stage gastric carcinoma.

Authors:  K Miwa; S Kinami; K Taniguchi; S Fushida; T Fujimura; A Nonomura
Journal:  Br J Surg       Date:  2003-02       Impact factor: 6.939

Review 2.  Diagnostic value of sentinel lymph node biopsy in gastric cancer: a meta-analysis.

Authors:  Zhen Wang; Zhi-Yong Dong; Jun-Qiang Chen; Jin-Lu Liu
Journal:  Ann Surg Oncol       Date:  2011-11-03       Impact factor: 5.344

3.  Japanese gastric cancer treatment guidelines 2010 (ver. 3).

Authors: 
Journal:  Gastric Cancer       Date:  2011-06       Impact factor: 7.370

4.  Application of sentinel node biopsy to gastric cancer surgery.

Authors:  M Hiratsuka; I Miyashiro; O Ishikawa; H Furukawa; K Motomura; H Ohigashi; M Kameyama; Y Sasaki; T Kabuto; S Ishiguro; S Imaoka; H Koyama
Journal:  Surgery       Date:  2001-03       Impact factor: 3.982

5.  Sentinel node mapping for gastric cancer: a prospective multicenter trial in Japan.

Authors:  Yuko Kitagawa; Hiroya Takeuchi; Yu Takagi; Shoji Natsugoe; Masanori Terashima; Nozomu Murakami; Takashi Fujimura; Hironori Tsujimoto; Hideki Hayashi; Nobunari Yoshimizu; Akinori Takagane; Yasuhiko Mohri; Kazuhito Nabeshima; Yoshikazu Uenosono; Shinichi Kinami; Junichi Sakamoto; Satoshi Morita; Takashi Aikou; Koichi Miwa; Masaki Kitajima
Journal:  J Clin Oncol       Date:  2013-09-09       Impact factor: 44.544

6.  Nanocolloidal albumin-IRDye 800CW: a near-infrared fluorescent tracer with optimal retention in the sentinel lymph node.

Authors:  Derrek A Heuveling; Gerard W M Visser; Mattijs de Groot; Johannes F de Boer; Marian Baclayon; Wouter H Roos; Gijs J L Wuite; C René Leemans; Remco de Bree; Guus A M S van Dongen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-02-17       Impact factor: 9.236

7.  Sentinel node concept in gastric carcinoma.

Authors:  Takashi Ichikura; Daisaku Morita; Takefumi Uchida; Eiji Okura; Takashi Majima; Toshiya Ogawa; Hidetaka Mochizuki
Journal:  World J Surg       Date:  2001-12-17       Impact factor: 3.352

8.  Application of the HyperEye Medical System for esophageal cancer surgery: a preliminary report.

Authors:  Keisuke Kubota; Masashi Yoshida; Junko Kuroda; Akihiro Okada; Keiichiro Ohta; Masaki Kitajima
Journal:  Surg Today       Date:  2012-07-11       Impact factor: 2.549

9.  High false-negative proportion of intraoperative histological examination as a serious problem for clinical application of sentinel node biopsy for early gastric cancer: final results of the Japan Clinical Oncology Group multicenter trial JCOG0302.

Authors:  Isao Miyashiro; Masahiro Hiratsuka; Mitsuru Sasako; Takeshi Sano; Junki Mizusawa; Kenichi Nakamura; Atsushi Nashimoto; Akira Tsuburaya; Norimasa Fukushima
Journal:  Gastric Cancer       Date:  2013-08-10       Impact factor: 7.370

10.  Sentinel node in gastric cancer surgery.

Authors:  M Carlini; F Carboni; M Petric; R Santoro; F Guadagni; F Marandino; M Castelli; E Santoro
Journal:  J Exp Clin Cancer Res       Date:  2002-12
View more
  23 in total

Review 1.  Laparoscopic sentinel node navigation surgery for early gastric cancer.

Authors:  Shinichi Kinami; Takeo Kosaka
Journal:  Transl Gastroenterol Hepatol       Date:  2017-05-09

Review 2.  [Fluorescence-guided detection of lymph node metastases of gastrointestinal tumors].

Authors:  Andrea Picchetto; Barbara Seeliger; Stefania La Rocca; Manuel Barberio; Giancarlo D'Ambrosio; Jacques Marescaux; Michele Diana
Journal:  Chirurg       Date:  2019-11       Impact factor: 0.955

Review 3.  How useful is sentinel lymph node biopsy for the status of lymph node metastasis in cT1N0M0 gastric cancer? A systematic review and meta-analysis.

Authors:  Yuqiang Huang; Mengting Pan; Zhiwei Deng; Yufei Ji; Bo Chen
Journal:  Updates Surg       Date:  2021-03-15

4.  Perspective of new techniques overcoming laparoscopic sentinel node biopsy for early gastric cancer.

Authors:  Shinichi Kinami
Journal:  Transl Gastroenterol Hepatol       Date:  2016-08-22

Review 5.  A Systematic Review and Meta-Analysis of Sentinel Lymph Node Biopsy in Gastric Cancer, an Optimization of Imaging Protocol for Tracer Mapping.

Authors:  Yuqiang Huang; Mengting Pan; Bo Chen
Journal:  World J Surg       Date:  2021-01-03       Impact factor: 3.352

6.  The Feasibility and Safety of Preoperative Fluorescence Marking with Indocyanine Green (ICG) in Laparoscopic Gastrectomy for Gastric Cancer.

Authors:  Yuki Ushimaru; Takeshi Omori; Yoshiyuki Fujiwara; Yoshitomo Yanagimoto; Keijiro Sugimura; Kazuyoshi Yamamoto; Jeong-Ho Moon; Hiroshi Miyata; Masayuki Ohue; Masahiko Yano
Journal:  J Gastrointest Surg       Date:  2018-08-06       Impact factor: 3.452

7.  Diagnostic evaluation of sentinel lymph node biopsy using indocyanine green and infrared or fluorescent imaging in gastric cancer: a systematic review and meta-analysis.

Authors:  Daniel Skubleny; Jerry T Dang; Samuel Skulsky; Noah Switzer; Chunhong Tian; Xinzhe Shi; Christopher de Gara; Daniel W Birch; Shahzeer Karmali
Journal:  Surg Endosc       Date:  2018-02-26       Impact factor: 4.584

8.  Time to maximum indocyanine green fluorescence of gastric sentinel lymph nodes and feasibility of combined indocyanine green/sodium fluorescein gastric lymphography.

Authors:  Jens Osterkamp; Rune B Strandby; Nikolaj Nerup; Morten Bo Søndergaard Svendsen; Lars Bo Svendsen; Michael Patrick Achiam
Journal:  Langenbecks Arch Surg       Date:  2021-07-10       Impact factor: 3.445

Review 9.  Recent Developments of ICG-Guided Sentinel Lymph Node Mapping in Oral Cancer.

Authors:  Ji-Hoon Kim; Minhee Ku; Jaemoon Yang; Hyung Kwon Byeon
Journal:  Diagnostics (Basel)       Date:  2021-05-17

Review 10.  Local resection of the stomach for gastric cancer.

Authors:  Shinichi Kinami; Hiroshi Funaki; Hideto Fujita; Yasuharu Nakano; Nobuhiko Ueda; Takeo Kosaka
Journal:  Surg Today       Date:  2016-06-24       Impact factor: 2.549

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.