A review of setup error in supine breast radiotherapy using cone-beam computed tomography.

Vikneswary Batumalai1, Lois Holloway2, Geoff P Delaney3.   

Abstract

Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.
Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Breast cancer; Cone-beam computed tomography (CBCT); Radiotherapy; Review; Setup errors

Mesh:

Year:  2016        PMID: 27311516     DOI: 10.1016/j.meddos.2016.05.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  10 in total

1.  Augmented reality-guided positioning system for radiotherapy patients.

Authors:  Chunying Li; Zhengda Lu; Mu He; Jianfeng Sui; Tao Lin; Kai Xie; Jiawei Sun; Xinye Ni
Journal:  J Appl Clin Med Phys       Date:  2022-01-05       Impact factor: 2.102

2.  Analysis of local setup errors of sub-regions in cone-beam CT-guided post-mastectomy radiation therapy.

Authors:  Jidan Zhou; Shuai Li; Chengwei Ye; Konglong Shen; An Li; Gang Chen; Xiaoyu Li; Sen Bai; Weifeng Wang; Renming Zhong
Journal:  J Radiat Res       Date:  2020-05-22       Impact factor: 2.724

3.  Setup Error Assessment and Correction in Planar kV Image- Versus Cone Beam CT Image-Guided Radiation Therapy: A Clinical Study of Early Breast Cancer Treated With External Beam Partial Breast Irradiation.

Authors:  Wei Wang; Ting Yu; Min Xu; Qian Shao; Yingjie Zhang; Jianbin Li
Journal:  Technol Cancer Res Treat       Date:  2019 Jan-Dec

4.  Dosimetric consequences of image guidance techniques on robust optimized intensity-modulated proton therapy for treatment of breast Cancer.

Authors:  Xiaoying Liang; Raymond B Mailhot Vega; Zuofeng Li; Dandan Zheng; Nancy Mendenhall; Julie A Bradley
Journal:  Radiat Oncol       Date:  2020-02-27       Impact factor: 3.481

5.  Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy.

Authors:  Konglong Shen; Jie Xiong; Zhiguo Wang; Weifeng Wang; Wan Li; Jidan Zhou; Zhonghua Deng; Bin Li; Renming Zhong
Journal:  J Radiat Res       Date:  2020-11-16       Impact factor: 2.724

6.  Breast-shape changes during radiation therapy after breast-conserving surgery.

Authors:  Tanja Alderliesten; Wilma D Heemsbergen; Anja Betgen; Rajko Topolnjak; Paula H M Elkhuizen; Corine van Vliet-Vroegindeweij; Peter Remeijer
Journal:  Phys Imaging Radiat Oncol       Date:  2018-05-31

7.  Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval.

Authors:  Dong Soo Lee; Young Kyu Lee; Young Nam Kang; Yong Gyun Won; Seung Hwan Park; Yong Seok Kim; Jeong Soo Kim; Hye Sung Won
Journal:  Sci Rep       Date:  2021-01-15       Impact factor: 4.379

8.  Compare of Interfractional Setup Reproducibility Between Vacuum-Lock Bag and Thermoplastic Mask in Radiotherapy for Breast Cancer.

Authors:  Yaqi Song; Jin Peng; Qianfeng Chen; Honglei Luo
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec

9.  Dosimetric effect of respiratory motion on planned dose in whole-breast volumetric modulated arc therapy using moderate and ultra-hypofractionation.

Authors:  Mikko Mankinen; Tuomas Virén; Jan Seppälä; Heikki Hakkarainen; Tuomas Koivumäki
Journal:  Radiat Oncol       Date:  2022-03-05       Impact factor: 3.481

10.  Setup error assessment based on "Sphere-Mask" Optical Positioning System: Results from a multicenter study.

Authors:  Yan Zhang; Han Zhou; Kaiyue Chu; Chuanfeng Wu; Yun Ge; Guoping Shan; Jundong Zhou; Jing Cai; Jianhua Jin; Weiyu Sun; Ying Chen; Xiaolin Huang
Journal:  Front Oncol       Date:  2022-10-04       Impact factor: 5.738

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.