OBJECTIVE: To evaluate the performance of Fetal Intelligent Navigation Echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volume datasets of the normal fetal heart in generating standard fetal echocardiography views. METHODS: In this prospective cohort study of patients with normal fetal hearts (19-30 gestational weeks), one or more STIC volume datasets were obtained of the apical four-chamber view. Each STIC volume successfully obtained was evaluated by STICLoop™ to determine its appropriateness before applying the FINE method. Visualization rates for standard fetal echocardiography views using diagnostic planes and/or Virtual Intelligent Sonographer Assistance (VIS-Assistance®) were calculated. RESULTS: One or more STIC volumes (total n = 463) were obtained from 246 patients. A single STIC volume per patient was analyzed using the FINE method. In normal cases, FINE was able to generate nine fetal echocardiography views using: (1) diagnostic planes in 76-100% of the cases, (2) VIS-Assistance® in 96-100% of the cases, and (3) a combination of diagnostic planes and/or VIS-Assistance® in 96-100% of the cases. CONCLUSION: FINE applied to STIC volumes can successfully generate nine standard fetal echocardiography views in 96-100% of cases in the 2nd and 3rd trimesters. This suggests that the technology can be used as a method of screening for congenital heart disease.
OBJECTIVE: To evaluate the performance of Fetal Intelligent Navigation Echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volume datasets of the normal fetal heart in generating standard fetal echocardiography views. METHODS: In this prospective cohort study of patients with normal fetal hearts (19-30 gestational weeks), one or more STIC volume datasets were obtained of the apical four-chamber view. Each STIC volume successfully obtained was evaluated by STICLoop™ to determine its appropriateness before applying the FINE method. Visualization rates for standard fetal echocardiography views using diagnostic planes and/or Virtual Intelligent Sonographer Assistance (VIS-Assistance®) were calculated. RESULTS: One or more STIC volumes (total n = 463) were obtained from 246 patients. A single STIC volume per patient was analyzed using the FINE method. In normal cases, FINE was able to generate nine fetal echocardiography views using: (1) diagnostic planes in 76-100% of the cases, (2) VIS-Assistance® in 96-100% of the cases, and (3) a combination of diagnostic planes and/or VIS-Assistance® in 96-100% of the cases. CONCLUSION: FINE applied to STIC volumes can successfully generate nine standard fetal echocardiography views in 96-100% of cases in the 2nd and 3rd trimesters. This suggests that the technology can be used as a method of screening for congenital heart disease.
Authors: P Volpe; G Tuo; V De Robertis; G Campobasso; M Marasini; A Tempesta; M Gentile; G Rembouskos Journal: Ultrasound Obstet Gynecol Date: 2010-03 Impact factor: 7.299
Authors: M Bennasar; J M Martínez; O Gómez; J Bartrons; A Olivella; B Puerto; E Gratacós Journal: Ultrasound Obstet Gynecol Date: 2010-10 Impact factor: 7.299
Authors: Alaina K Kipps; Colin Feuille; Anthony Azakie; Julien I E Hoffman; Sarah Tabbutt; Michael M Brook; Anita J Moon-Grady Journal: Am J Cardiol Date: 2011-05-31 Impact factor: 2.778
Authors: P M Verheijen; L A Lisowski; P Stoutenbeek; J F Hitchcock; G B W E Bennink; E J Meijboom Journal: Ultrasound Obstet Gynecol Date: 2002-06 Impact factor: 7.299