Literature DB >> 27306782

Posterior capsular opacification in highly myopic eyes with an endocapsular equator ring.

Tsutomu Hara1, Takeshi Hara2, Takako Hashimoto2, Yuta Motoyama2, Masaya Narita2.   

Abstract

PURPOSE: Closed 9.5-mm-diameter endocapsular equator rings (E-rings) prevent posterior capsular opacification (PCO). However, in our research, some highly myopic patients unexpectedly developed late, extensive PCO that required capsulotomy. We also report for the first time how the capsule reacted to neodymium-doped yttrium aluminium garnet (Nd:YAG) laser shots.
METHODS: Sixty-two eyes (39 patients; average age, 48 ± 13.2 years) were implanted with a closed, square-edged silicone E-ring (outer diameter, 9.5 mm) and an intraocular lens between April 16, 2008, and November 30, 2011.
RESULTS: During the postoperative, minimal 2-year follow-up, PCO requiring Nd:YAG laser capsulotomy developed in six (9.7 %) of 62 eyes, of which five had -8.75 to -12.5 diopters (D) of myopia preoperatively. The axial lengths of those eyes ranged from 25.86 to 29.97 mm. However, none of the 13 eyes with higher myopia had severe PCO that required capsulotomy. All capsulotomies were performed uneventfully.
CONCLUSION: The standard 9.5-mm-diameter closed E-ring does not prevent extensive PCO in eyes with preoperative myopia ranging between -8.75 and -12.5 D and an axial length between 25.86 and 29.97 mm. Posterior capsulotomies were performed safely. Further study is needed to determine why PCO did not occur in more high myopic eyes (larger axial length eyes).

Entities:  

Keywords:  Capsulotomy; Endocapsular equator ring; Nd:YAG laser; Posterior capsular opacification

Mesh:

Substances:

Year:  2016        PMID: 27306782     DOI: 10.1007/s10384-016-0456-y

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  12 in total

1.  Inhibition of posterior capsule opacification by a capsular adhesion-preventing ring.

Authors:  Toshiyuki Nagamoto; Nobushige Tanaka; Takaaki Fujiwara
Journal:  Arch Ophthalmol       Date:  2009-04

2.  Prevention of capsular bag opacification with a modified hydrophilic acrylic disk-shaped intraocular lens.

Authors:  Lisa Leishman; Liliana Werner; Zachary Bodnar; Andrew Ollerton; Jennifer Michelson; Mason Schmutz; Nick Mamalis
Journal:  J Cataract Refract Surg       Date:  2012-07-15       Impact factor: 3.351

3.  Equator ring efficacy in maintaining capsular bag integrity and transparency after cataract removal in monkey eyes.

Authors:  M Hashizoe; T Hara; Y Ogura; K Sakanishi; T Honda; T Hara
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1998-05       Impact factor: 3.117

4.  Efficacy of equator rings in an experimental rabbit study.

Authors:  T Hara; T Hara; K Sakanishi; Y Yamada
Journal:  Arch Ophthalmol       Date:  1995-08

5.  Long-term study of posterior capsular opacification prevention with endocapsular equator rings in humans.

Authors:  Tsutomu Hara; Takeshi Hara; Masaya Narita; Takako Hashimoto; Yuta Motoyama; Takako Hara
Journal:  Arch Ophthalmol       Date:  2011-03-14

6.  Prediction of pseudophakic capsular bag diameter based on biometric variables.

Authors:  C Vass; R Menapace; K Schmetterer; O Findl; G Rainer; I Steineck
Journal:  J Cataract Refract Surg       Date:  1999-10       Impact factor: 3.351

7.  Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation.

Authors:  Mana Tehrani; H Burkhard Dick; Frank Krummenauer; Gudrun Pfirrmann; Thomas Boyle; Bernhard M Stoffelns
Journal:  J Cataract Refract Surg       Date:  2003-11       Impact factor: 3.351

8.  "Equator ring" for maintenance of the completely circular contour of the capsular bag equator after cataract removal.

Authors:  T Hara; T Hara; Y Yamada
Journal:  Ophthalmic Surg       Date:  1991-06

9.  Preventing posterior capsular opacification with an endocapsular equator ring in a young human eye: 2-year follow-up.

Authors:  Tsutomu Hara; Takeshi Hara; Takako Hara
Journal:  Arch Ophthalmol       Date:  2007-04

10.  Nd: YAG laser posterior capsulotomy rates in myopic eyes after implantation of capsular tension ring.

Authors:  Sadullah Keles; Baki Kartal; Aytekin Apil; Osman Ondas; Betul Dertsiz Kozan; Elif Topdagi; Metin Ekinci; Erdinc Ceylan; Orhan Baykal
Journal:  Med Sci Monit       Date:  2014-08-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.