Literature DB >> 2729135

Comparison of transthoracic and transesophageal color Doppler flow imaging in patients with mechanical prostheses in the mitral valve position.

R B van den Brink1, C A Visser, D C Basart, D R Düren, A P de Jong, A J Dunning.   

Abstract

This study determined the relative value of transthoracic and transesophageal color Doppler flow imaging to systolic flow patterns in the left atrium in different types of mechanical prostheses in the mitral valve. Thirty-nine patients were investigated. Based on clinical findings, 36 of 39 patients had normal prosthetic valve function. Seventeen patients were interrogated within a few days after surgery. Systolic regurgitant jets in the left atrium were absent in all patients by both transthoracic pulsed and color Doppler flow imaging. Using transthoracic continuous wave Doppler, however, jets were demonstrated in 8 of 39 patients (21%). Transesophageal color Doppler flow imaging demonstrated systolic regurgitant jets originating from the prosthesis in all patients. Tilting disc valves showed jets during the entire systole (closure and leakage backflow). Each type of prosthesis generated a specific jet pattern. Pathologic regurgitant jets were crescent-shaped, more extensive and turbulent than jets caused by normal closure and leakage backflow. Thus, transthoracic color Doppler flow imaging is not sensitive for detecting regurgitant jets in mechanical prostheses in the mitral valve. All mechanical prostheses show a specific jet pattern, which should be helpful when transesophageal echocardiography is used to identify pathologic backflow.

Entities:  

Mesh:

Year:  1989        PMID: 2729135     DOI: 10.1016/0002-9149(89)90010-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  6 in total

Review 1.  Transoesophageal echocardiography.

Authors:  J E Sanderson; W W Chan
Journal:  Postgrad Med J       Date:  1997-03       Impact factor: 2.401

2.  Severe haemolytic anaemia after replacement of the mitral valve by a St Jude medical prosthesis.

Authors:  I W Black; A Hopkins; C L Lee; B Jacobson; W F Walsh
Journal:  Br Heart J       Date:  1990-07

3.  Detection of acute thrombosis of mitral tilting disk prosthesis by transesophageal echocardiography.

Authors:  P Ius; A Giacomin; A Cavarzerani; C Valfré
Journal:  Int J Card Imaging       Date:  1994-12

4.  Echocardiographic assessment of artificial heart valves: British Society of Echocardiography position paper.

Authors:  J Chambers; A Fraser; P Lawford; P Nihoyannopoulos; I Simpson
Journal:  Br Heart J       Date:  1994-04

5.  Routine cine-CMR for prosthesis-associated mitral regurgitation: a multicenter comparison to echocardiography.

Authors:  Lauren A Simprini; Anika Afroz; Mitchell A Cooper; Igor Klem; Christoph Jensen; Raymond J Kim; Monvadi B Srichai; John F Heitner; Michael Sood; Elizabeth Chandy; Dipan J Shah; Juan Lopez-Mattei; Robert W Biederman; John D Grizzard; Anthon Fuisz; Kambiz Ghafourian; Afshin Farzaneh-Far; Jonathan Weinsaft
Journal:  J Heart Valve Dis       Date:  2014-09

Review 6.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.