Literature DB >> 27288090

Multimodality Assessment of Ascending Aortic Diameters: Comparison of Different Measurement Methods.

José F Rodríguez-Palomares1, Gisela Teixidó-Tura1, Valentina Galuppo1, Hug Cuéllar2, Ana Laynez1, Laura Gutiérrez1, María Teresa González-Alujas1, David García-Dorado1, Arturo Evangelista3.   

Abstract

BACKGROUND: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters.
METHODS: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter- and intraobserver variability was analyzed.
RESULTS: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter- and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 ± 2.6 mm [P = .158] for MDCT and 0.4 ± 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI.
CONCLUSIONS: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.
Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aortic root; Ascending aorta; Cardiac magnetic resonance; Computed tomography; Transthoracic echocardiography

Mesh:

Year:  2016        PMID: 27288090     DOI: 10.1016/j.echo.2016.04.006

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  14 in total

1.  Measuring the aorta in the era of multimodality imaging: still to be agreed.

Authors:  Elena Díaz-Peláez; Manuel Barreiro-Pérez; Ana Martín-García; Pedro L Sanchez
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

Review 2.  Multimodality imaging assessment of bicuspid aortic valve disease, thoracic aortic ectasia, and thoracic aortic aneurysmal disease.

Authors:  Preethi Mani; Reza Reyaldeen; Bo Xu
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

3.  The American Association for Thoracic Surgery consensus guidelines on bicuspid aortic valve-related aortopathy: Full online-only version.

Authors:  Michael A Borger; Paul W M Fedak; Elizabeth H Stephens; Thomas G Gleason; Evaldas Girdauskas; John S Ikonomidis; Ali Khoynezhad; Samuel C Siu; Subodh Verma; Michael D Hope; Duke E Cameron; Donald F Hammer; Joseph S Coselli; Marc R Moon; Thoralf M Sundt; Alex J Barker; Michael Markl; Alessandro Della Corte; Hector I Michelena; John A Elefteriades
Journal:  J Thorac Cardiovasc Surg       Date:  2018-08       Impact factor: 5.209

Review 4.  Marfan syndrome.

Authors:  Dianna M Milewicz; Alan C Braverman; Julie De Backer; Shaine A Morris; Catherine Boileau; Irene H Maumenee; Guillaume Jondeau; Arturo Evangelista; Reed E Pyeritz
Journal:  Nat Rev Dis Primers       Date:  2021-09-02       Impact factor: 65.038

5.  Cardiovascular Multimodality Imaging: It is Time to Get on Board! A "Società Italiana di Ecocardiografia e CardioVascular Imaging" Statement.

Authors:  Francesco Antonini-Canterin; Giorgio Faganello; Antonio Mantero; Rodolfo Citro; Paolo Colonna; Mauro Giorgi; Vincenzo Manuppelli; Ines Monte; Licia Petrella; Alfredo Posteraro; Vitantonio Di Bello; Scipione Carerj; Frank Benedetto
Journal:  J Cardiovasc Echogr       Date:  2018 Jan-Mar

6.  Validation of thoracic aortic dimensions on ECG-triggered SSFP as alternative to contrast-enhanced MRA.

Authors:  G J H Snel; L M Hernandez; R H J A Slart; C T Nguyen; D E Sosnovik; V M van Deursen; R A J O Dierckx; B K Velthuis; R J H Borra; N H J Prakken
Journal:  Eur Radiol       Date:  2020-06-07       Impact factor: 5.315

Review 7.  Aortic Dilatation in Patients With Bicuspid Aortic Valve.

Authors:  Jing Wang; Wenhui Deng; Qing Lv; Yuman Li; Tianshu Liu; Mingxing Xie
Journal:  Front Physiol       Date:  2021-07-06       Impact factor: 4.566

Review 8.  A systematic approach to 3D echocardiographic assessment of the aortic root.

Authors:  Andreas Hagendorff; Stephan Stoebe; Bhupendar Tayal
Journal:  Glob Cardiol Sci Pract       Date:  2018-06-30

Review 9.  Unraveling Bicuspid Aortic Valve Enigmas by Multimodality Imaging: Clinical Implications.

Authors:  Arturo Evangelista Masip; Laura Galian-Gay; Andrea Guala; Angela Lopez-Sainz; Gisela Teixido-Turà; Aroa Ruiz Muñoz; Filipa Valente; Laura Gutierrez; Ruben Fernandez-Galera; Guillem Casas; Alejandro Panaro; Alba Marigliano; Marina Huguet; Teresa González-Alujas; Jose Rodriguez-Palomares
Journal:  J Clin Med       Date:  2022-01-17       Impact factor: 4.241

10.  Systematic Review of Studies That Have Evaluated Screening Tests in Relatives of Patients Affected by Nonsyndromic Thoracic Aortic Disease.

Authors:  Giovanni Mariscalco; Radoslaw Debiec; John A Elefteriades; Nilesh J Samani; Gavin J Murphy
Journal:  J Am Heart Assoc       Date:  2018-08-07       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.