Literature DB >> 27282892

Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.

Saami K Yazdani1,2, Alexander Sheehy3, Stephen Pacetti3, Brandon Rittlemeyer2, Frank D Kolodgie1, Renu Virmani4.   

Abstract

BACKGROUND: Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response.
OBJECTIVE: The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. METHODS AND
RESULTS: Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking.
CONCLUSION: Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo.
© 2016, Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27282892     DOI: 10.1111/joic.12303

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  6 in total

Review 1.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

2.  Polymer Coating Integrity, Thrombogenicity and Computational Fluid Dynamics Analysis of Provisional Stenting Technique in the Left Main Bifurcation Setting: Insights from an In-Vitro Model.

Authors:  Marek Milewski; Chen Koon Jaryl Ng; Pawel Gąsior; Shaoliang Shawn Lian; Su Xiao Qian; Shengjie Lu; Nicolas Foin; Elvin Kedhi; Wojciech Wojakowski; Hui Ying Ang
Journal:  Polymers (Basel)       Date:  2022-04-22       Impact factor: 4.967

3.  Fully implantable wireless batteryless vascular electronics with printed soft sensors for multiplex sensing of hemodynamics.

Authors:  Robert Herbert; Hyo-Ryoung Lim; Bruno Rigo; Woon-Hong Yeo
Journal:  Sci Adv       Date:  2022-05-11       Impact factor: 14.957

4.  Scanning Electron Microscopic Assessment of Stent Coating Integrity in Jailed Wire Technique for Bifurcation Treatment.

Authors:  Lijian Gao; Ce Zhang; Huanhuan Wang; Yiqun Zhang; Zhan Gao; Bo Xu; Jue Chen; Jinqing Yuan; Shubin Qiao; Jilin Chen
Journal:  J Interv Cardiol       Date:  2021-05-24       Impact factor: 2.279

5.  Heparin-Tagged PLA-PEG Copolymer-Encapsulated Biochanin A-Loaded (Mg/Al) LDH Nanoparticles Recommended for Non-Thrombogenic and Anti-Proliferative Stent Coating.

Authors:  Shivakalyani Adepu; Hongrong Luo; Seeram Ramakrishna
Journal:  Int J Mol Sci       Date:  2021-05-21       Impact factor: 5.923

6.  Comparison of overexpansion capabilities and thrombogenicity at the side branch ostia after implantation of four different drug eluting stents.

Authors:  Pawel Gasior; Shengjie Lu; Chen Koon Jaryl Ng; Wee Yee Daniel Toong; En Hou Philip Wong; Nicolas Foin; Elvin Kedhi; Wojciech Wojakowski; Hui Ying Ang
Journal:  Sci Rep       Date:  2020-11-27       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.