Literature DB >> 27278692

Analysis of the intensity of radio-frequency signals in intracranial ultrasonography of preterm infants.

Ko Ichihashi1, Yukari Yada2, Naoto Takahashi2, Yoko Honma2, Mariko Momoi2.   

Abstract

PURPOSE: The purpose of this study was to evaluate the usefulness of analysis of the intensity of radio-frequency (RF) signals in intracranial ultrasonography of preterm infants.
METHODS: Twenty neonatal infants admitted to the neonatal intensive care unit of our hospital were included in this study. Their gestational age was 33-35 weeks. The studies were performed with a System 5 ultrasound system with 3.0-and 5.0-MHz transducers. The transducer was placed on the anterior fontanel to obtain images. Regions of interest were determined based on B-mode images and were positioned at the thalamus, caudate nucleus, cerebral white matter, cerebellum, brain stem, and lateral ventricle. The software used for analysis of the RF signals was EchoMAT (Vingmed Ultrasound).
RESULTS: The RF signals of the ventricle and the choroid plexus showed the lowest and the highest intensities, respectively. The intensities of the brain stem and vermis signals were the same, and were higher than the intensity of the cerebellar hemisphere. The thalamus and caudate nucleus showed macroscopically identical brightness levels; however, the intensity of the thalamus was lower than that of the caudate nucleus. The intensity of subependymal hemorrhage was lower than that of the caudothalamic groove. The intensity of subependymal cyst was the same as that of the lateral ventricle. The RF signal frequencies and intensities were distinctive in each tissue.
CONCLUSION: The results of this study suggest that measurement of RF signal intensity may be useful to differentiate macroscopically similar lesions.

Entities:  

Keywords:  RF signal; cranial ultrasonography; preterm infant

Year:  2008        PMID: 27278692     DOI: 10.1007/s10396-007-0171-x

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  7 in total

1.  In vivo quantitative ultrasonic evaluation of neonatal brain with a real time integrated backscatter imaging system.

Authors:  Chizu Fujimoto; Yushiro Yamashita; Hiroshi Kanda; Eimei Harada; Yasuki Maeno; Toyojiro Matsuishi
Journal:  Brain Dev       Date:  2003-09       Impact factor: 1.961

2.  Clinical assessment of gestational age in the newborn infant.

Authors:  L M Dubowitz; V Dubowitz; C Goldberg
Journal:  J Pediatr       Date:  1970-07       Impact factor: 4.406

3.  Sonographic finding of the bright thalamus.

Authors:  E Y Shen; C C Huang; S C Chyou; H Y Hung; C H Hsu; F Y Huang
Journal:  Arch Dis Child       Date:  1986-11       Impact factor: 3.791

4.  Recent developments in tissue-type imaging (TTI) for planning and monitoring treatment of prostate cancer.

Authors:  Ernest J Feleppa; Christopher R Porter; Jeffrey Ketterling; Paul Lee; Shreedevi Dasgupta; Stella Urban; Andrew Kalisz
Journal:  Ultrason Imaging       Date:  2004-07       Impact factor: 1.578

5.  The diagnostic and prognostic implications of brain hyperechogenicity in hypoxic-ischaemic encephalopathy grade II.

Authors:  I Ivanov; M Neshterova
Journal:  Eur J Ultrasound       Date:  1998-09

6.  Backscatter evaluation of myocardial functional and textural findings in children with right ventricular pressure and/or volume overload.

Authors:  Giuseppe Pacileo; Giuseppe Limongelli; Marina Verrengia; Juan Gimeno; Giovanni Di Salvo; Raffaele Calabrò
Journal:  Am J Cardiol       Date:  2004-03-01       Impact factor: 2.778

7.  Severe aortic stenosis and myocardial function: diagnostic and prognostic usefulness of ultrasonic integrated backscatter analysis.

Authors:  Vitantonio Di Bello; Davide Giorgi; Paolo Viacava; Talini Enrica; Carmela Nardi; Caterina Palagi; Maria Grazia Delle Donne; Francesco Verunelli; Massimo A Mariani; Jean Grandjean; Rita Dell'Anna; Andrea Di Cori; Giulio Zucchelli; Maria Francesca Romano; Mario Mariani
Journal:  Circulation       Date:  2004-08-09       Impact factor: 29.690

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.