Literature DB >> 27278266

Diagnostic reference levels for common paediatric fluoroscopic examinations performed at a dedicated paediatric Australian hospital.

Giovanni Bibbo1, Debbie Balman1, Rebecca Linke1.   

Abstract

INTRODUCTION: Diagnostic reference levels (DRL) of procedures involving ionising radiation are important tools for optimising radiation doses delivered to patients and to identify cases where the levels of dose are unusually high. This is particularly important for paediatric patients undergoing fluoroscopic examinations as these examinations can be associated with a high radiation dose. In this study, a large amount of paediatric fluoroscopic data has been analysed to: establish local DRL, identify the most significant factors determining radiation dose to patients, and modify fluoroscopic techniques to optimise the examination protocols.
METHODS: Paediatric fluoroscopic studies performed at our institution from April 2010 to May 2015 have been retrospectively analysed to determine range, mean, 75th and 95th percentiles of Dose-Area Product (DAP) and fluoroscopic screening time for Micturating Cystourethrography (MCU), Airway, Airway and Swallow, Barium Swallow and Meal, Barium Follow Through and Barium Enema studies.
RESULTS: Currently, no Australian paediatric fluoroscopic DRL data are available for comparison and thus our data can only be compared with international published data. No major changes to examination protocols or modification to fluoroscopic techniques were found necessary as our data compared well with the international published values.
CONCLUSION: The dose delivered to patients depend on a number of factors particularly the experience of the operators. However, DRL are also important, as shown in this study, as they enable best practice by providing feedback to the operators on their performance and benchmarking the institution with other institutions.
© 2016 The Royal Australian and New Zealand College of Radiologists.

Entities:  

Keywords:  diagnostic reference levels; fluoroscopic screening time; paediatric fluoroscopic DAP; paediatric fluoroscopic DRL

Mesh:

Year:  2016        PMID: 27278266     DOI: 10.1111/1754-9485.12478

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  3 in total

1.  Radiation Dose During Videofluoroscopic Swallowing Studies and Associated Factors in Pediatric Patients.

Authors:  Hyo Won Im; Seung Yeun Kim; Byung-Mo Oh; Tai Ryoon Han; Han Gil Seo
Journal:  Dysphagia       Date:  2019-04-03       Impact factor: 3.438

Review 2.  Radiation Exposure to Staff and Patient During Videofluoroscopic Swallowing Studies and Recommended Protection Strategies.

Authors:  Victoria Jean Earl; Mohamed Khaldoun Badawy
Journal:  Dysphagia       Date:  2018-09-22       Impact factor: 3.438

3.  Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy.

Authors:  David Célier; Patrice Roch; Cécile Etard; Hubert Ducou Le Pointe; Hervé J Brisse
Journal:  Eur Radiol       Date:  2019-09-16       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.