Literature DB >> 27278220

Laparoscopic ventral hernia repair using a novel intraperitoneal lightweight mesh coated with hyaluronic acid: 1-year follow-up from a case-control study using the Hernia-Club registry.

J-F Gillion1, G Fromont2, M Lepère3, N Letoux4, A Dabrowski5, C Zaranis6, C Barrat7.   

Abstract

PURPOSE: A case-control study was performed to compare laparoscopic ventral hernia repair (LVHR) using the Ventralight ST™ lightweight surgical mesh with LVHR using other types of mesh.
METHODS: Adult patients undergoing intraperitoneal implantation of Ventralight ST™ during LVHR (Ventralight ST™ group; VG) over a 2-year period (2011-2013) were identified from the prospective French Hernia-Club registry. Patients undergoing elective LVHR using other types of intraperitoneal mesh in the first semester of 2013 formed the control group (CG). Patient, hernia and surgical characteristics, and postoperative outcomes after 8 days, 1 month, and 1 year were compared between the two groups.
RESULTS: The VG comprised 90 LVHRs in 85 patients, and the CG 86 LVHRs in 81 patients. Patient, hernia and surgical characteristics were similar between the two groups, apart from the method of mesh fixation and the number of procedures involving fascial closure. A low rate of minor complications was observed in both groups at 1 month [4.4 % (VG) and 2.3 % (CG)], and the level of postoperative pain was similar in the two groups at Day 8 and 1 month. After 1 year, no complications, recurrences or cases of chronic pain had occurred in either group, and Quality-of-Life outcomes were similar. Patients rated their procedure as excellent or good in 96 % (VG) and 92 % (CG) of cases.
CONCLUSIONS: Ventralight ST™ mesh is effective and well tolerated in LVHR, producing very low complication and recurrence rates in the short and medium term. The results are comparable to those achieved with other types of mesh.

Entities:  

Keywords:  Case–control study; Intraperitoneal mesh repair; Laparoscopic hernia repair; Lightweight mesh; Registry; Ventral hernia repair

Mesh:

Substances:

Year:  2016        PMID: 27278220     DOI: 10.1007/s10029-016-1501-y

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  30 in total

1.  Randomized clinical trial comparing lightweight composite mesh with polyester or polypropylene mesh for incisional hernia repair.

Authors:  J Conze; A N Kingsnorth; J B Flament; R Simmermacher; G Arlt; C Langer; E Schippers; M Hartley; V Schumpelick
Journal:  Br J Surg       Date:  2005-12       Impact factor: 6.939

2.  Hospital-level variability in incisional hernia repair technique affects patient outcomes.

Authors:  Mary T Hawn; Christopher W Snyder; Laura A Graham; Stephen H Gray; Kelly R Finan; Catherine C Vick
Journal:  Surgery       Date:  2011-02       Impact factor: 3.982

3.  Preventing intraperitoneal adhesions with linezolid and hyaluronic acid/carboxymethylcellulose: a comparative study in cecal abrasion model.

Authors:  Kasim Caglayan; Bulent Gungor; Hamza Cinar; Nilsen Y Erdogan; Bulent Koca
Journal:  Am J Surg       Date:  2014-03-26       Impact factor: 2.565

4.  Functional abdominal wall reconstruction improves core physiology and quality-of-life.

Authors:  Cory N Criss; Clayton C Petro; David M Krpata; Christina M Seafler; Nicola Lai; Justin Fiutem; Yuri W Novitsky; Michael J Rosen
Journal:  Surgery       Date:  2014-07       Impact factor: 3.982

5.  Chronic pain and quality of life (QoL) after transinguinal preperitoneal (TIPP) inguinal hernia repair using a totally extraperitoneal, parietalized, Polysoft ® memory ring patch : a series of 622 hernia repairs in 525 patients.

Authors:  J-F Gillion; J-M Chollet
Journal:  Hernia       Date:  2013-06-23       Impact factor: 4.739

6.  Evaluation of new prosthetic meshes for ventral hernia repair.

Authors:  J W A Burger; J A Halm; A R Wijsmuller; S ten Raa; J Jeekel
Journal:  Surg Endosc       Date:  2006-07-24       Impact factor: 4.584

7.  Prospective analysis of laparoscopic ventral hernia repair using the Ventralight™ ST hernia patch with or without the ECHO PS™ positioning system.

Authors:  Tim Tollens; Halit Topal; Koen Vermeiren; Chris Aelvoet
Journal:  Surg Technol Int       Date:  2014-03

8.  Closing the gap: medialization of fascia with laparoscopic incisional hernia repair.

Authors:  L Panait; R L Bell; K E Roberts; A J Duffy
Journal:  Hernia       Date:  2013-06-30       Impact factor: 4.739

9.  Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society (IEHS)-part 1.

Authors:  R Bittner; J Bingener-Casey; U Dietz; M Fabian; G S Ferzli; R H Fortelny; F Köckerling; J Kukleta; K Leblanc; D Lomanto; M C Misra; V K Bansal; S Morales-Conde; B Ramshaw; W Reinpold; S Rim; M Rohr; R Schrittwieser; Th Simon; M Smietanski; B Stechemesser; M Timoney; P Chowbey
Journal:  Surg Endosc       Date:  2013-10-11       Impact factor: 4.584

Review 10.  Strengthening the Reporting of Observational Studies in Epidemiology (STROBE): explanation and elaboration.

Authors:  Jan P Vandenbroucke; Erik von Elm; Douglas G Altman; Peter C Gøtzsche; Cynthia D Mulrow; Stuart J Pocock; Charles Poole; James J Schlesselman; Matthias Egger
Journal:  PLoS Med       Date:  2007-10-16       Impact factor: 11.069

View more
  5 in total

1.  Patient's satisfaction at 2 years after groin hernia repair: any difference according to the technique?

Authors:  B Romain; J-F Gillion; P Ortega-Deballon; N Meyer
Journal:  Hernia       Date:  2018-07-03       Impact factor: 4.739

2.  Safety and efficacy of absorbable and non-absorbable fixation systems for intraperitoneal mesh fixation: an experimental study in swine.

Authors:  S Kapoulas; A Papalois; G Papadakis; G Tsoulfas; E Christoforidis; B Papaziogas; D Schizas; G Chatzimavroudis
Journal:  Hernia       Date:  2021-01-05       Impact factor: 4.739

Review 3.  Comparison of hernia registries: the CORE project.

Authors:  I Kyle-Leinhase; F Köckerling; L N Jørgensen; A Montgomery; J F Gillion; J A P Rodriguez; W Hope; F Muysoms
Journal:  Hernia       Date:  2018-01-06       Impact factor: 4.739

4.  Assessing the Validity and Cover Rate of the National Swedish Hernia Register.

Authors:  Erik Axman; Pär Nordin; Marina Modin; Hanna de la Croix
Journal:  Clin Epidemiol       Date:  2021-12-16       Impact factor: 4.790

5.  Predictive factors of recurrence for laparoscopic repair of primary and incisional ventral hernias with single mesh from a multicenter study.

Authors:  Micaela Piccoli; Francesca Pecchini; Gaetano Vetrone; Romano Linguerri; Giuliano Sarro; Umberto Rivolta; Amedeo Elio; Gianluca Piccirillo; Giuseppe Faillace; Emilia Masci; Davide Guglielminetti; Chiara Santorelli; Giorgio Soliani; Margherita Koleva Radica; Vincenzo Trapani; Domenico Marchi; Johanna Chester; Luca Leonardi; Silvia Neri
Journal:  Sci Rep       Date:  2022-03-10       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.