Literature DB >> 27277259

Assessing pediatric ileocolonic Crohn's disease activity based on global MR enterography scores.

Fabio Pomerri1, Faise Al Bunni2, Monica Zuliani3, Graziella Guariso4, Marco Gasparetto4, Benedetta Giorgi3, Mara Cananzi4, Pier Carlo Muzzio3.   

Abstract

OBJECTIVES: This study was aimed at correlating a magnetic resonance index of activity (MaRIA) and a magnetic resonance enterography global score (MEGS) with activity indexes in a paediatric population with Crohn's disease (CD).
METHODS: This retrospective study included 32 paediatric patients (median age 14.5 years, 18 male) with proven CD who underwent magnetic resonance enterography (MRE). A correlation analysis was performed on the MRE-based scores, the simplified endoscopic score for CD (SES-CD), the paediatric Crohn's disease activity index (PCDAI), and C-reactive protein (CRP) levels. Based on PCDAI, comparison of both global MaRIA and MEGS was made between patients with mild and moderate/severe disease activity.
RESULTS: Global MaRIA correlated with SES-CD (r = 0.70, p = 0.001) and PCDAI (r = 0.42, p = 0.016). MEGS correlated with PCDAI (r = 0.46, p = 0.007) and CRP levels (r = 0.35, p = 0.046). MEGS differed significantly (p = 0.027) between patients grouped by clinical disease severity.
CONCLUSIONS: MRE-based global scores correlated with clinical indexes of CD activity. Therefore, they represent a potential useful tool to predict CD activity and severity, as well as a possible promising alternative to endoscopy, to monitor paediatric patients with CD during their follow-up. KEY POINTS: • MRE is widely used to for accurate assessment of CD. • Global MaRIA and MEGS have been suggested as indicators of CD activity. • Paediatric studies comparing MRE-based global scores with clinical CD activity are lacking. • Such scores can serve as predictors of CD activity/severity in paediatric patients. • MRE offers an alternative to clinical score/endoscopy for paediatric CD monitoring.

Entities:  

Keywords:  Crohn’s disease; Disease activity; Disease severity; Magnetic resonance enterography; Paediatrics

Mesh:

Year:  2016        PMID: 27277259     DOI: 10.1007/s00330-016-4443-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  27 in total

1.  MR enterography versus capsule endoscopy in paediatric patients with suspected Crohn's disease.

Authors:  Emanuele Casciani; Gabriele Masselli; Giovanni Di Nardo; Elisabetta Polettini; Luca Bertini; Salvatore Oliva; Irene Floriani; Salvatore Cucchiara; Gianfranco Gualdi
Journal:  Eur Radiol       Date:  2010-10-05       Impact factor: 5.315

2.  Evaluation of Crohn's disease activity: initial validation of a magnetic resonance enterography global score (MEGS) against faecal calprotectin.

Authors:  Jesica C Makanyanga; Doug Pendsé; Nikolaos Dikaios; Stuart Bloom; Sara McCartney; Emma Helbren; Elaine Atkins; Terry Cuthbertson; Shonit Punwani; Alastair Forbes; Steve Halligan; Stuart A Taylor
Journal:  Eur Radiol       Date:  2013-09-12       Impact factor: 5.315

3.  Magnetic resonance enterography for suspected inflammatory bowel disease in a pediatric population.

Authors:  Karin Horsthuis; Lissy de Ridder; Anne M J B Smets; Maarten S van Leeuwen; Marc A Benninga; Roderick H J Houwen; Annemieke S Littooij; Rutger A J Nievelstein; Jaap Stoker
Journal:  J Pediatr Gastroenterol Nutr       Date:  2010-11       Impact factor: 2.839

Review 4.  A review of activity indices and end points for clinical trials in children with Crohn's disease.

Authors:  Anne M Griffiths; Anthony R Otley; Jeffrey Hyams; Antonio R Quiros; Richard J Grand; Athos Bousvaros; Brian G Feagan; George R Ferry
Journal:  Inflamm Bowel Dis       Date:  2005-02       Impact factor: 5.325

5.  Evaluation of the pediatric crohn disease activity index: a prospective multicenter experience.

Authors:  Jeffrey Hyams; James Markowitz; Anthony Otley; Joel Rosh; David Mack; Athos Bousvaros; Subra Kugathasan; M Pfefferkorn; Vasundhara Tolia; Jonathan Evans; William Treem; Robert Wyllie; Robert Rothbaum; J del Rosario; Aubrey Katz; Adam Mezoff; M Oliva-Hemker; Trudy Lerer; Anne Griffiths
Journal:  J Pediatr Gastroenterol Nutr       Date:  2005-10       Impact factor: 2.839

6.  Non-perforating small bowel Crohn's disease assessed by MRI enterography: derivation and histopathological validation of an MR-based activity index.

Authors:  Michael J Steward; Shonit Punwani; Ian Proctor; Yvette Adjei-Gyamfi; Fiona Chatterjee; Stuart Bloom; Marco Novelli; Steve Halligan; Manuel Rodriguez-Justo; Stuart A Taylor
Journal:  Eur J Radiol       Date:  2011-09-15       Impact factor: 3.528

7.  Comparison of MR enterography and histopathology in the evaluation of pediatric Crohn disease.

Authors:  Jonathan R Dillman; Maria F Ladino-Torres; Jeremy Adler; Vera DeMatos-Malliard; Jonathan B McHugh; Shokoufeh Khalatbari; Peter J Strouse
Journal:  Pediatr Radiol       Date:  2011-07-23

8.  Development and validation of an endoscopic index of the severity for Crohn's disease: a prospective multicentre study. Groupe d'Etudes Thérapeutiques des Affections Inflammatoires du Tube Digestif (GETAID).

Authors:  J Y Mary; R Modigliani
Journal:  Gut       Date:  1989-07       Impact factor: 23.059

9.  Magnetic resonance for assessment of disease activity and severity in ileocolonic Crohn's disease.

Authors:  J Rimola; S Rodriguez; O García-Bosch; I Ordás; E Ayala; M Aceituno; M Pellisé; C Ayuso; E Ricart; L Donoso; J Panés
Journal:  Gut       Date:  2009-01-09       Impact factor: 23.059

Review 10.  Grading of Crohn's disease activity using CT, MRI, US and scintigraphy: a meta-analysis.

Authors:  C A J Puylaert; J A W Tielbeek; S Bipat; J Stoker
Journal:  Eur Radiol       Date:  2015-06-17       Impact factor: 5.315

View more
  4 in total

1.  Capsule Endoscopy versus Magnetic Resonance Enterography for Evaluation of Pediatric Small Bowel Crohn's Disease: Prospective Study.

Authors:  Jae-Yeon Hwang; Sang-Wook Moon; Yeoun Joo Lee; Jae Hong Park; Yong-Woo Kim; Tae Un Kim; Hwaseong Ryu
Journal:  J Clin Med       Date:  2022-05-13       Impact factor: 4.964

Review 2.  A review of magnetic resonance enterography-based indices for quantification of Crohn's disease inflammation.

Authors:  Noa Rozendorn; Marianne Michal Amitai; Rami Abraham Eliakim; Uri Kopylov; Eyal Klang
Journal:  Therap Adv Gastroenterol       Date:  2018-04-13       Impact factor: 4.409

Review 3.  A review of magnetic resonance enterography based Crohn's disease activity indices in paediatric patients.

Authors:  Roma B Herman; Paulina Dumnicka; Krzysztof Fyderek
Journal:  Prz Gastroenterol       Date:  2022-03-24

4.  Comparison of small intestinal contrast ultrasound with magnetic resonance enterography in pediatric Crohn's disease.

Authors:  Aishah Hakim; Christopher Alexakis; James Pilcher; Demitrios Tzias; Sally Mitton; Thankam Paul; Sonia Saxena; Richard Pollok; Shankar Kumar
Journal:  JGH Open       Date:  2019-07-19
  4 in total