Measurement of regional pulse wave velocity using very high frame rate ultrasound.

Hideyuki Hasegawa1,2, Kazue Hongo3, Hiroshi Kanai3,4.   

Abstract

PURPOSE: Pulse wave velocity (PWV) is the propagation velocity of the pressure wave along the artery due to the heartbeat. The PWV becomes faster with progression of arteriosclerosis and, thus, can be used as a diagnostic index of arteriosclerosis. Measurement of PWV is known as a noninvasive approach for diagnosis of arteriosclerosis and is widely used in clinical situations. In the traditional PWV method, the average PWV is calculated between two points, the carotid and femoral arteries, at an interval of several tens of centimeters. However, PWV depends on part of the arterial tree, i.e., PWVs in the distal arteries are faster than those in the proximal arteries. Therefore, measurement of regional PWV is preferable.
METHODS: To evaluate regional PWV in the present study, the minute vibration velocity of the human carotid arterial wall was measured at intervals of 0.2 mm at 72 points in the arterial longitudinal direction by the phased-tracking method at a high temporal resolution of 3472 Hz, and PWV was estimated by applying the Hilbert transform to those waveforms.
RESULTS: In the present study, carotid arteries of three healthy subjects were measured in vivo. The PWVs in short segments of 14.4 mm in the arterial longitudinal direction were estimated to be 5.6, 6.4, and 6.7 m/s, which were in good agreement with those reported in the literature. Furthermore, for one of the subjects, a component was clearly found propagating from the periphery to the direction of the heart, i.e., a well known component reflected by the peripheral arteries. By using the proposed method, the propagation speed of the reflection component was also separately estimated to be -8.4 m/s. The higher magnitude of PWV for the reflection component was considered to be the difference in blood pressure at the arrivals of the forward and reflection components.
CONCLUSION: Such a method would be useful for more sensitive evaluation of the change in elasticity due to progression of arteriosclerosis by measuring the regional PWV in a specific artery of interest (not the average PWV including other arteries).

Entities:  

Keywords:  High frame rate; Parallel beam forming; Regional pulse wave velocity

Year:  2012        PMID: 27277096     DOI: 10.1007/s10396-012-0400-9

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  28 in total

1.  Evaluation of three-dimensional segmentation algorithms for the identification of luminal and medial-adventitial borders in intravascular ultrasound images.

Authors:  J D Klingensmith; R Shekhar; D G Vince
Journal:  IEEE Trans Med Imaging       Date:  2000-10       Impact factor: 10.048

2.  Relationship of aortic pressure and diameter in the dog.

Authors:  G O BARNETT; A J MALLOS; A SHAPIRO
Journal:  J Appl Physiol       Date:  1961-05       Impact factor: 3.531

3.  Noninvasive vascular elastography: theoretical framework.

Authors:  Roch L Maurice; Jacques Ohayon; Yves Frétigny; Michel Bertrand; Gilles Soulez; Guy Cloutier
Journal:  IEEE Trans Med Imaging       Date:  2004-02       Impact factor: 10.048

4.  Optimal region-of-interest settings for tissue characterization based on ultrasonic elasticity imaging.

Authors:  Kentaro Tsuzuki; Hideyuki Hasegawa; Masataka Ichiki; Fumiaki Tezuka; Hiroshi Kanai
Journal:  Ultrasound Med Biol       Date:  2008-01-09       Impact factor: 2.998

5.  Simultaneous imaging of artery-wall strain and blood flow by high frame rate acquisition of RF signals.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-12       Impact factor: 2.725

6.  Reduction of influence of variation in center frequencies of RF echoes on estimation of artery-wall strain.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

7.  Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis.

Authors:  I B Wilkinson; S A Fuchs; I M Jansen; J C Spratt; G D Murray; J R Cockcroft; D J Webb
Journal:  J Hypertens       Date:  1998-12       Impact factor: 4.844

8.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2011-05-07       Impact factor: 1.314

9.  Changes in aortic distensibility and area ratio with the development of atherosclerosis.

Authors:  D L Newman; R G Gosling; N L Bowden
Journal:  Atherosclerosis       Date:  1971 Sep-Oct       Impact factor: 5.162

10.  Carotid arterial elasticity is a sensitive atherosclerosis value reflecting visceral fat accumulation in obese subjects.

Authors:  Ai Tokita; Yasushi Ishigaki; Hisashi Okimoto; Hideyuki Hasegawa; Yoshiro Koiwa; Makoto Kato; Hisamitsu Ishihara; Yoshinori Hinokio; Hideki Katagiri; Hiroshi Kanai; Yoshitomo Oka
Journal:  Atherosclerosis       Date:  2009-02-20       Impact factor: 5.162

View more
  9 in total

1.  Temporal averaging of two-dimensional correlation functions for velocity vector imaging of cardiac blood flow.

Authors:  Hiroki Takahashi; Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2015-03-17       Impact factor: 1.314

2.  Apodized adaptive beamformer.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2017-01-13       Impact factor: 1.314

3.  Improvement of penetration of modified amplitude and phase estimation beamformer.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2016-07-21       Impact factor: 1.314

4.  Arterial wall mechanical inhomogeneity detection and atherosclerotic plaque characterization using high frame rate pulse wave imaging in carotid artery disease patients in vivo.

Authors:  Grigorios M Karageorgos; Iason Z Apostolakis; Pierre Nauleau; Vittorio Gatti; Rachel Weber; E Sander Connolly; Eliza C Miller; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2020-01-17       Impact factor: 3.609

5.  Feasibility and Validation of 4-D Pulse Wave Imaging in Phantoms and In Vivo.

Authors:  Iason-Zacharias Apostolakis; Pierre Nauleau; Clement Papadacci; Matthew D McGarry; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-08-03       Impact factor: 2.725

6.  Adaptive Pulse Wave Imaging: Automated Spatial Vessel Wall Inhomogeneity Detection in Phantoms and in-Vivo.

Authors:  Iason Z Apostolakis; Grigorios M Karageorgos; Pierre Nauleau; Sacha D Nandlall; Elisa E Konofagou
Journal:  IEEE Trans Med Imaging       Date:  2019-07-01       Impact factor: 10.048

7.  Performance assessment of Pulse Wave Imaging using conventional ultrasound in canine aortas ex vivo and normal human arteries in vivo.

Authors:  Ronny X Li; William Qaqish; Elisa E Konofagou
Journal:  Artery Res       Date:  2015-07-22       Impact factor: 0.597

8.  Pulse Wave Imaging Coupled With Vector Flow Mapping: A Phantom, Simulation, and In Vivo Study.

Authors:  Grigorios Marios Karageorgos; Iason-Zacharias Apostolakis; Pierre Nauleau; Vittorio Gatti; Rachel Weber; Paul Kemper; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-06-29       Impact factor: 3.267

9.  Design of an Ultrasound Transceiver ASIC with a Switching-Artifact Reduction Technique for 3D Carotid Artery Imaging.

Authors:  Taehoon Kim; Fabian Fool; Djalma Simoes Dos Santos; Zu-Yao Chang; Emile Noothout; Hendrik J Vos; Johan G Bosch; Martin D Verweij; Nico de Jong; Michiel A P Pertijs
Journal:  Sensors (Basel)       Date:  2020-12-29       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.