Literature DB >> 19126487

Simultaneous imaging of artery-wall strain and blood flow by high frame rate acquisition of RF signals.

Hideyuki Hasegawa1, Hiroshi Kanai.   

Abstract

Mechanical properties of the arterial walls are significantly altered by atherosclerosis, and various studies have been recently conducted to measure the regional elastic properties (radial strain) of the arterial wall. We have developed a phase-sensitive correlation-based method, namely, the phased-tracking method, to measure the regional radial strain. On the other hand, the measurement of blood flow is an important practical routine in the diagnosis of atherosclerosis. It would be useful if the regional strain of the arterial wall as well as blood flow could be assessed simultaneously. Such measurement would require a high frame rate of several kilohertz. In this study, acquisition of ultrasonic RF echoes at a high frame rate (about 3500 Hz) was achieved using parallel beamforming in which plane waves were transmitted only 3 times and receive beamforming created 24 beams for each transmit beam. The accuracy in measurement of the minute radial strain was evaluated by a basic experiment using a cylindrical phantom. The error of the measured strain from the theoretical strain profile and its standard deviation were 4.8% and 9.5%, respectively. Furthermore, the radial strain of a carotid arterial wall and blood flow were simultaneously imaged in vivo.

Entities:  

Mesh:

Year:  2008        PMID: 19126487     DOI: 10.1109/TUFFC.2008.978

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  13 in total

1.  Temporal averaging of two-dimensional correlation functions for velocity vector imaging of cardiac blood flow.

Authors:  Hiroki Takahashi; Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2015-03-17       Impact factor: 1.314

2.  Apodized adaptive beamformer.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2017-01-13       Impact factor: 1.314

3.  Improvement of penetration of modified amplitude and phase estimation beamformer.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2016-07-21       Impact factor: 1.314

4.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2011-05-07       Impact factor: 1.314

Review 5.  New developments in paediatric cardiac functional ultrasound imaging.

Authors:  Chris L de Korte; Maartje M Nillesen; Anne E C M Saris; Richard G P Lopata; Johan M Thijssen; Livia Kapusta
Journal:  J Med Ultrason (2001)       Date:  2013-12-20       Impact factor: 1.314

6.  Impact of element pitch on synthetic aperture ultrasound imaging.

Authors:  Hideyuki Hasegawa; Chris L de Korte
Journal:  J Med Ultrason (2001)       Date:  2016-02-20       Impact factor: 1.314

7.  Measurement of regional pulse wave velocity using very high frame rate ultrasound.

Authors:  Hideyuki Hasegawa; Kazue Hongo; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2012-10-10       Impact factor: 1.314

8.  Quantification of carotid artery plaque stability with multiple region of interest based ultrasound strain indices and relationship with cognition.

Authors:  N H Meshram; T Varghese; C C Mitchell; D C Jackson; S M Wilbrand; B P Hermann; R J Dempsey
Journal:  Phys Med Biol       Date:  2017-07-17       Impact factor: 3.609

9.  Imaging of wall motion coupled with blood flow velocity in the heart and vessels in vivo: a feasibility study.

Authors:  Jianwen Luo; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2011-05-05       Impact factor: 2.998

10.  Vascular ultrasound for atherosclerosis imaging.

Authors:  Chris L de Korte; Hendrik H G Hansen; Anton F W van der Steen
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.