Literature DB >> 27275436

Efficacy, safety, predictability, aberrations and corneal biomechnical parameters after SMILE and FLEx: Meta-analysis.

Jing Ma1, Nan-Jue Cao1, Li-Kun Xia1.   

Abstract

AIM: To identify possible differences of efficacy, safety, predictability, higher-order aberrations and corneal biomechnical parameters after small-incision lenticule extraction (SMILE) and femtosecond lenticule extraction (FLEx).
METHODS: A systematic literature retrieval was conducted in Medline, Embase and the Cochrane Library, up to October, 2015. The included studies were subject to a Meta-analysis. Comparison between SMILE and FLEx was measured as pooled odds ratio (OR) or weighted mean differences (WMD). Of 95% confidence intervals (CI) were used to analyze data.
RESULTS: A total of seven studies were included. Firstly, there were no differences in uncorrected distance visual acuity (UDVA) 20/20 or better (OR, 1.37; 95% CI, 0.69 to 2.69; P=0.37) and logMAR UDVA (WMD, -0.02; 95% CI, -0.05 to 0.01; P=0.17) after SMILE versus FLEx. We found no differences in corrected distance visual acuity (CDVA) unchanged (OR, 0.98; 95% CI, 0.46 to 2.11; P=0.97) and logMAR CDVA (WMD, -0.00; 95% CI, -0.01 to 0.01; P=0.90) either. Secondly, we found no differences in refraction within ±1.00 D (OR, 0.98; 95% CI, 0.13 to 7.28; P=0.99) and ±0.50 D (OR, 1.62; 95% CI, 0.62 to 4.28; P=0.33) of target postoperatively. Thirdly, for higher-order aberrations, we found no differences in the total higher-order aberrations (WMD, -0.04; 95% CI, -0.09 to 0.01; P=0.14), coma (WMD, -0.04; 95% CI, -0.09 to 0.01; P=0.11), spherical (WMD, 0.01; 95% CI, -0.02 to 0.03; P=0.60) and trefoil (WMD, -0.00; 95% CI, -0.04 to 0.03; P=0.76). Furthermore, for corneal biomechanical parameters, we also found no differences (WMD, 0.08; 95% CI, -0.17 to 0.33; P=0.54) after SMILE versus FLEx.
CONCLUSION: There are no statistically differences in efficacy, safety, predictability, higher-order aberrations and corneal biomechnical parameters postoperative between SMILE and FLEx.

Entities:  

Keywords:  aberrations; corneal biomechnical parameters; femtosecond lenticule extraction; small-incision lenticule extraction; visual quality

Year:  2016        PMID: 27275436      PMCID: PMC4886878          DOI: 10.18240/ijo.2016.05.22

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  28 in total

1.  Results of small incision lenticule extraction: All-in-one femtosecond laser refractive surgery.

Authors:  Rupal Shah; Samir Shah; Sayantan Sengupta
Journal:  J Cataract Refract Surg       Date:  2011-01       Impact factor: 3.351

2.  Femtosecond laser-assisted corneal flap cuts: morphology, accuracy, and histopathology.

Authors:  Mike P Holzer; Tanja M Rabsilber; Gerd U Auffarth
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-07       Impact factor: 4.799

3.  [Influence of diameter of optical zone ablation on LASIK-induced higher order optical aberrations in myopia].

Authors:  Zhen-ying Cheng; Ren-yuan Chu; Xing-tao Zhou
Journal:  Zhonghua Yan Ke Za Zhi       Date:  2006-09

4.  Efficacy, safety, predictability, contrast sensitivity, and aberrations after femtosecond laser lenticule extraction.

Authors:  Anders H Vestergaard; Jakob Grauslund; Anders R Ivarsen; Jesper Ø Hjortdal
Journal:  J Cataract Refract Surg       Date:  2014-01-27       Impact factor: 3.351

5.  Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry.

Authors:  Iben Bach Pedersen; Sashia Bak-Nielsen; Anders Højslet Vestergaard; Anders Ivarsen; Jesper Hjortdal
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-27       Impact factor: 3.117

6.  Intraindividual comparison of changes in corneal biomechanical parameters after femtosecond lenticule extraction and small-incision lenticule extraction.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Akihito Igarashi; Hidenaga Kobashi; Nobuyuki Sato; Rie Ishii
Journal:  J Cataract Refract Surg       Date:  2014-04-17       Impact factor: 3.351

7.  Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study.

Authors:  Walter Sekundo; Kathleen S Kunert; Marcus Blum
Journal:  Br J Ophthalmol       Date:  2010-07-03       Impact factor: 4.638

8.  Femtosecond (FS) laser vision correction procedure for moderate to high myopia: a prospective study of ReLEx(®) flex and comparison with a retrospective study of FS-laser in situ keratomileusis.

Authors:  Anders Vestergaard; Anders Ivarsen; Sven Asp; Jesper Ø Hjortdal
Journal:  Acta Ophthalmol       Date:  2012-04-18       Impact factor: 3.761

9.  One-year refractive results, contrast sensitivity, high-order aberrations and complications after myopic small-incision lenticule extraction (ReLEx SMILE).

Authors:  Walter Sekundo; Jana Gertnere; Thomas Bertelmann; Igor Solomatin
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-03-20       Impact factor: 3.117

10.  Vector analysis of low to moderate astigmatism with small incision lenticule extraction (SMILE): results of a 1-year follow-up.

Authors:  Jiamei Zhang; Yan Wang; Wenjing Wu; Lulu Xu; Xiaojing Li; Rui Dou
Journal:  BMC Ophthalmol       Date:  2015-01-24       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.