Literature DB >> 17173735

[Influence of diameter of optical zone ablation on LASIK-induced higher order optical aberrations in myopia].

Zhen-ying Cheng1, Ren-yuan Chu, Xing-tao Zhou.   

Abstract

OBJECTIVE: To analyze the effects of optical zone ablation diameter on LASIK-induced higher order optical aberrations in myopia.
METHODS: Four hundred and sixty-one eyes of 236 patients treated with LASIK for myopia were divided into high, moderate and low myopia group according to preoperative spherical equivalent diopter. In each group, eyes were divided into four subgroups according to optic zone ablation diameter. Before and after surgery 6 months, monochromatic wavefront aberrations of each eye were objectively measured using WASCA Analyzer Aberrometer. F test and q test were used to analyze the difference of total high order, horizontal coma, vertical coma, and spherical aberrations among four subgroups in each group at 4, 5, and 6 mm pupil size.
RESULTS: Before surgery no significant difference of higher order aberrations among four subgroups was found. After surgery, there was significant difference of total high order, and spherical aberrations among four subgroups. Total high order, and spherical aberrations in larger optical zone ablation diameter subgroup were significantly lower than that in smaller one. The difference was significant at 4, 5, and 6 mm pupil size in high myopia group, and 6 mm pupil size in low myopia group. At 6 mm pupil size, the difference was significant between each subgroup in high myopia group and subgroup I and subgroup IV in low myopia group. There was no significant difference of horizontal coma, and vertical coma aberrations among four subgroups.
CONCLUSIONS: Optical zone ablation diameter has influence on LASIK-induced higher order optical aberrations. Larger optical zone can decrease total higher order and spherical aberrations after LASIK. The effects are more significant in high myopia group than in low myopia group.

Entities:  

Mesh:

Year:  2006        PMID: 17173735

Source DB:  PubMed          Journal:  Zhonghua Yan Ke Za Zhi        ISSN: 0412-4081


  2 in total

1.  Efficacy, safety, predictability, aberrations and corneal biomechnical parameters after SMILE and FLEx: Meta-analysis.

Authors:  Jing Ma; Nan-Jue Cao; Li-Kun Xia
Journal:  Int J Ophthalmol       Date:  2016-05-18       Impact factor: 1.779

2.  Utility of orthokeratology contact lenses; efficacy of myopia correction and level of patient satisfaction in Iranian myopic/myope-astigmatic patients.

Authors:  Mohammad Taher Rajabi; Seyedeh Simindokht Hosseini; Zahra Ghorbani; Fereshteh Nobahari; Fatemeh Bazvand; Askar Doostdar; Parviz Zarrinbakhsh; Mohammad Bagher Rajabi
Journal:  J Curr Ophthalmol       Date:  2016-02-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.