Literature DB >> 27268082

Metal artefact reduction for patients with metallic dental fillings in helical neck computed tomography: comparison of adaptive iterative dose reduction 3D (AIDR 3D), forward-projected model-based iterative reconstruction solution (FIRST) and AIDR 3D with single-energy metal artefact reduction (SEMAR).

Koichiro Yasaka1, Kouhei Kamiya1, Ryusuke Irie1, Eriko Maeda1, Jiro Sato1, Kuni Ohtomo1.   

Abstract

OBJECTIVES: To compare the differences in metal artefact degree and the depiction of structures in helical neck CT, in patients with metallic dental fillings, among adaptive iterative dose reduction three dimensional (AIDR 3D), forward-projected model-based iterative reconstruction solution (FIRST) and AIDR 3D with single-energy metal artefact reduction (SEMAR-A).
METHODS: In this retrospective clinical study, 22 patients (males, 13; females, 9; mean age, 64.6 ± 12.6 years) with metallic dental fillings who underwent contrast-enhanced helical CT involving the oropharyngeal region were included. Neck axial images were reconstructed with AIDR 3D, FIRST and SEMAR-A. Metal artefact degree and depiction of structures (the apex and root of the tongue, parapharyngeal space, superior portion of the internal jugular chain and parotid gland) were evaluated on a four-point scale by two radiologists. Placing regions of interest, standard deviations of the oral cavity and nuchal muscle (at the slice where no metal exists) were measured and metal artefact indices were calculated (the square root of the difference of the squares of them).
RESULTS: In SEMAR-A, metal artefact was significantly reduced and depictions of all structures were significantly improved compared with those in FIRST and AIDR 3D (p ≤ 0.001, sign test). Metal artefact index for the oral cavity in AIDR 3D/FIRST/SEMAR-A was 572.0/477.7/88.4, and significant differences were seen between each reconstruction algorithm (p < 0.0001, Wilcoxon signed-rank test).
CONCLUSIONS: SEMAR-A could provide images with lesser metal artefact and better depiction of structures than AIDR 3D and FIRST.

Entities:  

Keywords:  CT; artefact; metal; neck; pharynx

Mesh:

Substances:

Year:  2016        PMID: 27268082      PMCID: PMC5606257          DOI: 10.1259/dmfr.20160114

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  19 in total

1.  Diagnosis of peritonsillar infections: a prospective study of ultrasound, computerized tomography and clinical diagnosis.

Authors:  P M Scott; W K Loftus; J Kew; A Ahuja; V Yue; C A van Hasselt
Journal:  J Laryngol Otol       Date:  1999-03       Impact factor: 1.469

Review 2.  Current philosophy on the management of cancer of the base of the tongue.

Authors:  Louis B Harrison; Alfio Ferlito; Ashok R Shaha; Patrick J Bradley; Eric M Genden; Alessandra Rinaldo
Journal:  Oral Oncol       Date:  2003-02       Impact factor: 5.337

3.  Reduction of dental metallic artefacts in CT: value of a newly developed algorithm for metal artefact reduction (O-MAR).

Authors:  M Kidoh; T Nakaura; S Nakamura; S Tokuyasu; H Osakabe; K Harada; Y Yamashita
Journal:  Clin Radiol       Date:  2013-10-22       Impact factor: 2.350

4.  Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT.

Authors:  Yue Dong; Ai Jun Shi; Jian Lin Wu; Ru Xin Wang; Li Fei Sun; Ai Lian Liu; Yi Jun Liu
Journal:  Eur Spine J       Date:  2015-06-13       Impact factor: 3.134

5.  Distribution of cervical lymph node metastases from squamous cell carcinoma of the upper respiratory and digestive tracts.

Authors:  R Lindberg
Journal:  Cancer       Date:  1972-06       Impact factor: 6.860

6.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

7.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

Authors:  Fabian Bamberg; Alexander Dierks; Konstantin Nikolaou; Maximilian F Reiser; Christoph R Becker; Thorsten R C Johnson
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

8.  Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT.

Authors:  X-Y Gong; E Meyer; X-J Yu; J-H Sun; L-P Sheng; K-H Huang; R-Z Wu
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

9.  Pseudoprogression of glioblastoma after chemo- and radiation therapy: diagnosis by using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging with ferumoxytol versus gadoteridol and correlation with survival.

Authors:  Seymur Gahramanov; Leslie L Muldoon; Csanad G Varallyay; Xin Li; Dale F Kraemer; Rongwei Fu; Bronwyn E Hamilton; William D Rooney; Edward A Neuwelt
Journal:  Radiology       Date:  2012-11-30       Impact factor: 11.105

10.  Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions.

Authors:  Fabian Morsbach; Moritz Wurnig; Daniel M Kunz; Andreas Krauss; Bernhard Schmidt; Spyros S Kollias; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-05-19       Impact factor: 5.315

View more
  9 in total

1.  Metal Artifact Reduction in Head CT Performed for Patients with Deep Brain Stimulation Devices: Effectiveness of a Single-Energy Metal Artifact Reduction Algorithm.

Authors:  Y Nagayama; S Tanoue; S Oda; D Sakabe; T Emoto; M Kidoh; H Uetani; A Sasao; T Nakaura; O Ikeda; K Yamada; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2019-12-26       Impact factor: 3.825

2.  Single-energy metal artifact reduction for helical computed tomography of the pelvis in patients with metal hip prostheses.

Authors:  Koichiro Yasaka; Eriko Maeda; Shouhei Hanaoka; Masaki Katsura; Jiro Sato; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2016-07-11       Impact factor: 2.374

3.  Utility of second-generation single-energy metal artifact reduction in helical lung computed tomography for patients with pulmonary arteriovenous malformation after coil embolization.

Authors:  Yudai Asano; Akihiro Tada; Takayoshi Shinya; Yoshihisa Masaoka; Toshihiro Iguchi; Shuhei Sato; Susumu Kanazawa
Journal:  Jpn J Radiol       Date:  2018-02-10       Impact factor: 2.374

4.  Improved Estimation of Coronary Plaque and Luminal Attenuation Using a Vendor-specific Model-based Iterative Reconstruction Algorithm in Contrast-enhanced CT Coronary Angiography.

Authors:  Yoshinori Funama; Daisuke Utsunomiya; Kenichiro Hirata; Katsuyuki Taguchi; Takeshi Nakaura; Seitaro Oda; Masafumi Kidoh; Hideaki Yuki; Yasuyuki Yamashita
Journal:  Acad Radiol       Date:  2017-04-07       Impact factor: 3.173

5.  Diagnostic Value of Model-Based Iterative Reconstruction Combined with a Metal Artifact Reduction Algorithm during CT of the Oral Cavity.

Authors:  Y Kubo; K Ito; M Sone; H Nagasawa; Y Onishi; N Umakoshi; T Hasegawa; T Akimoto; M Kusumoto
Journal:  AJNR Am J Neuroradiol       Date:  2020-09-24       Impact factor: 3.825

6.  Metal artifacts reduction in computed tomography: A phantom study to compare the effectiveness of metal artifact reduction algorithm, model-based iterative reconstruction, and virtual monochromatic imaging.

Authors:  Takuya Ishikawa; Shigeru Suzuki; Shingo Harashima; Rika Fukui; Masafumi Kaiume; Yoshiaki Katada
Journal:  Medicine (Baltimore)       Date:  2020-12-11       Impact factor: 1.817

7.  Subtraction iodine imaging with area detector CT to improve tumor delineation and measurability of tumor size and depth of invasion in tongue squamous cell carcinoma.

Authors:  Takashi Hiyama; Hirofumi Kuno; Kotaro Sekiya; So Tsushima; Shioto Oda; Tatsushi Kobayashi
Journal:  Jpn J Radiol       Date:  2021-09-16       Impact factor: 2.374

8.  Microtomographic Analysis of a Palaeolithic Wooden Point from the Ljubljanica River.

Authors:  Enej Guček Puhar; Lidija Korat; Miran Erič; Aleš Jaklič; Franc Solina
Journal:  Sensors (Basel)       Date:  2022-03-18       Impact factor: 3.576

9.  The effect of the reconstruction algorithm for the pulmonary nodule detection under the metal artifact caused by a pacemaker.

Authors:  Noriko Kikuchi; Masahiro Yanagawa; Yukihiro Enchi; Akiko Nakayama; Yuriko Yoshida; Tomo Miyata; Akinori Hata; Mitsuko Tsubamoto; Osamu Honda; Noriyuki Tomiyama
Journal:  Medicine (Baltimore)       Date:  2020-06-12       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.