Literature DB >> 27264484

The utility of thromboelastography in inherited and acquired bleeding disorders.

Keiji Nogami1.   

Abstract

Thromboelastography (TEG) was first described by Hartert in 1948, and was designed to monitor viscoelastic clot strength in whole blood in real time. The current TEG method and Rotational Thromboelastometry (ROTEM) were subsequently developed from the original principles. Both of the modern methods provide data by measuring changes in the viscoelastic strength of a small sample of clotting blood in response to a constant rotational force. The important advantage of these techniques is to visually observe and quantify blood coagulation including the propagation, stabilization and dissolution phases of clot formation under low shear conditions. Analysis of the results provides detailed kinetic data on fibrin generation, clot strength and fibrinolysis. These TEG/ROTEM analyses therefore enable evaluation of global clotting function and the monitoring of haemostatic treatment in various clinical situations, not only in patients with genetic bleeding disorders, such as haemophilia, but also in patients undergoing cardiac surgery, liver transplantation or suffering from traumatic injury. Some evidence suggests that haemostatic management using TEG/ROTEM leads to a reduction in total transfusions of whole blood or clotting factors. Wider clinical application of this technology seems likely.
© 2016 John Wiley & Sons Ltd.

Entities:  

Keywords:  bleeding disorders; haemophilia; monitoring; thromboelastography

Mesh:

Year:  2016        PMID: 27264484     DOI: 10.1111/bjh.14148

Source DB:  PubMed          Journal:  Br J Haematol        ISSN: 0007-1048            Impact factor:   6.998


  18 in total

1.  The use of viscoelastic haemostatic assays in non-cardiac surgical settings: a systematic review and meta-analysis.

Authors:  Massimo Franchini; Carlo Mengoli; Mario Cruciani; Marco Marietta; Giuseppe Marano; Stefania Vaglio; Simonetta Pupella; Eva Veropalumbo; Francesca Masiello; Giancarlo M Liumbruno
Journal:  Blood Transfus       Date:  2018-02-26       Impact factor: 3.443

2.  The use of viscoelastic haemostatic assays in non-cardiac surgical settings: a systematic review and meta-analysis.

Authors:  Raimondo De Cristofaro
Journal:  Blood Transfus       Date:  2018-03-05       Impact factor: 3.443

3.  First report of real-time monitoring of coagulation function potential and IgG subtype of anti-FVIII autoantibodies in a child with acquired hemophilia A associated with streptococcal infection and amoxicillin.

Authors:  Masahiro Takeyama; Keiji Nogami; Takahiro Kajimoto; Kenichi Ogiwara; Tomoko Matsumoto; Midori Shima
Journal:  Int J Hematol       Date:  2017-06-08       Impact factor: 2.490

4.  Global coagulation function assessed by rotational thromboelastometry predicts coagulation-steady state in individual hemophilia A patients receiving emicizumab prophylaxis.

Authors:  Koji Yada; Keiji Nogami; Kenichi Ogiwara; Yasuaki Shida; Shoko Furukawa; Hiroaki Yaoi; Masahiro Takeyama; Ryu Kasai; Midori Shima
Journal:  Int J Hematol       Date:  2019-06-28       Impact factor: 2.490

5.  Acquired haemophilia A: Italian Consensus Recommendations on diagnosis, general management and treatment of bleeding.

Authors:  Antonio Coppola; Massimo Franchini; Armando Tripodi; Rita C Santoro; Giancarlo Castaman; Renato Marino; Ezio Zanon; Cristina Santoro; Gianna F Rivolta; Laura Contino; Raimondo De Cristofaro; Angelo C Molinari; Paolo Gresele; Angiola Rocino
Journal:  Blood Transfus       Date:  2022-01-20       Impact factor: 5.752

6.  Recombinant Factor VIII Measurement in a Hemophilia A Patient Undergoing Cardiopulmonary Bypass-Supported Cardiac Surgery.

Authors:  Jennifer Bezaire; Dorothy Thomson; Erick McNair
Journal:  J Extra Corpor Technol       Date:  2018-09

7.  Case Report: Rotational Thromboelastometry in Taipan Envenomation.

Authors:  Catherine L Tacon; Azhar Munas; Mark Little
Journal:  Am J Trop Med Hyg       Date:  2021-11-01       Impact factor: 2.345

Review 8.  Quality Assessment of Established and Emerging Blood Components for Transfusion.

Authors:  Jason P Acker; Denese C Marks; William P Sheffield
Journal:  J Blood Transfus       Date:  2016-12-14

9.  Evaluation of recombinant factor VIII Fc (Eloctate) activity by thromboelastometry in a multicenter phase 3 clinical trial and correlation with bleeding phenotype.

Authors:  Frank Driessler; Maricel G Miguelino; Glenn F Pierce; Robert T Peters; Jurg M Sommer
Journal:  Blood Coagul Fibrinolysis       Date:  2017-10       Impact factor: 1.276

10.  How Can Rotational Thromboelastometry as a Point-of-Care Method Be Useful for the Management of Secondary Thromboprophylaxis in High-Risk Pregnant Patients?

Authors:  Lucia Stanciakova; Miroslava Dobrotova; Pavol Holly; Jana Zolkova; Lubica Vadelova; Ingrid Skornova; Jela Ivankova; Tomas Bolek; Matej Samos; Marian Grendar; Jan Danko; Peter Kubisz; Jan Stasko
Journal:  Diagnostics (Basel)       Date:  2021-05-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.