Literature DB >> 27260342

Fine-needle aspiration versus core needle biopsy for diagnosis of thyroid malignancy and neoplasm: a matched cohort study.

Soo-Yeon Kim1, Hye Sun Lee2, Jieun Moon2, Eun-Kyung Kim1, Hee Jung Moon1, Jung Hyun Yoon1, Jin Young Kwak3.   

Abstract

OBJECTIVES: To compare the diagnostic performances of fine-needle aspiration (FNA) and core needle biopsy (CNB) in the diagnosis of thyroid malignancy and neoplasm in patients who underwent surgery for thyroid nodules.
METHODS: This retrospective study was approved by the institutional review board, and the need to obtain informed consent was waived. 3192 patients who underwent FNA (n = 3048) or CNB (n = 144) for diagnosis of thyroid nodules and then proceeded with surgery were included. Surgical pathologic diagnosis was the reference standard. Diagnostic performances of FNA and CNB to predict malignancy and neoplasm were compared. Propensity score matching was used to match patients with FNA with those with CNB because there were significant differences in the number of nodules and nodule characteristics between the FNA and CNB groups.
RESULTS: Before matching, the sensitivity and accuracy of FNA were significantly higher or comparable with those of CNB, and the specificity, negative predictive value and positive predictive value were comparable. After matching, the diagnostic performances were similar, with the exception of specificity for predicting neoplasm being higher with CNB than with FNA.
CONCLUSION: FNA showed comparable diagnostic performance to CNB; therefore, there may be no benefit in performing CNB to diagnose papillary thyroid carcinoma and neoplasm. KEY POINTS: • Diagnostic performances of FNA and CNB for thyroid malignancy and neoplasm were compared. • FNA showed comparable performances to CNB both before and after statistical matching. • There may be no benefit in performing CNB, given the comparable performances.

Entities:  

Keywords:  Core needle biopsy; Fine needle aspiration; Malignancy; Neoplasm; Thyroid

Mesh:

Year:  2016        PMID: 27260342     DOI: 10.1007/s00330-016-4424-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  37 in total

1.  New sonographic criteria for recommending fine-needle aspiration biopsy of nonpalpable solid nodules of the thyroid.

Authors:  Eun-Kyung Kim; Cheong Soo Park; Woung Youn Chung; Ki Keun Oh; Dong Ik Kim; Jong Tae Lee; Hyung Sik Yoo
Journal:  AJR Am J Roentgenol       Date:  2002-03       Impact factor: 3.959

2.  A comparison of the ability of different propensity score models to balance measured variables between treated and untreated subjects: a Monte Carlo study.

Authors:  Peter C Austin; Paul Grootendorst; Geoffrey M Anderson
Journal:  Stat Med       Date:  2007-02-20       Impact factor: 2.373

3.  Simple core-needle biopsy for thyroid nodule, complicated tinnitus.

Authors:  Mathieu Bergeron; Danielle Beaudoin
Journal:  Eur Thyroid J       Date:  2014-06-07

4.  The role of core needle biopsy in the preoperative diagnosis of follicular neoplasm of the thyroid.

Authors:  Hye Sook Min; Ji-Hoon Kim; Inseon Ryoo; So Lyung Jung; Chan Kwon Jung
Journal:  APMIS       Date:  2014-03-28       Impact factor: 3.205

5.  US-guided fine needle aspiration versus coarse needle biopsy of thyroid nodules.

Authors:  S Karstrup; E Balslev; N Juul; P C Eskildsen; L Baumbach
Journal:  Eur J Ultrasound       Date:  2001-04

Review 6.  Role of ultrasound-guided core-needle biopsy in the assessment of head and neck lesions: a meta-analysis and systematic review of the literature.

Authors:  Eva Novoa; Nicolas Gürtler; André Arnoux; Marcel Kraft
Journal:  Head Neck       Date:  2011-08-24       Impact factor: 3.147

7.  Patient's comfort with and tolerability of thyroid core needle biopsy.

Authors:  Naim Nasrollah; Pierpaolo Trimboli; Fabio Rossi; Stefano Amendola; Leo Guidobaldi; Claudio Ventura; Riccardo Maglio; Giuseppe Nigri; Francesco Romanelli; Stefano Valabrega; Anna Crescenzi
Journal:  Endocrine       Date:  2013-05-15       Impact factor: 3.633

8.  Diagnosis of thyroid follicular neoplasm: fine-needle aspiration versus core-needle biopsy.

Authors:  Ra Gyoung Yoon; Jung Hwan Baek; Jeong Hyun Lee; Young Jun Choi; Min Ji Hong; Dong Eun Song; Jae Kyun Kim; Jong Ho Yoon; Won Bae Kim
Journal:  Thyroid       Date:  2014-09-19       Impact factor: 6.568

9.  Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration.

Authors:  Sang Hyun Choi; Jung Hwan Baek; Jeong Hyun Lee; Young Jun Choi; Min Ji Hong; Dong Eun Song; Jae Kyun Kim; Jong Ho Yoon; Won Bae Kim
Journal:  Eur Radiol       Date:  2014-07-20       Impact factor: 5.315

Review 10.  Effectiveness and limitations of core needle biopsy in the diagnosis of thyroid nodules: review of current literature.

Authors:  Jung Hyun Yoon; Eun-Kyung Kim; Jin Young Kwak; Hee Jung Moon
Journal:  J Pathol Transl Med       Date:  2015-05-15
View more
  11 in total

1.  Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

Authors:  In Hye Chae; Eun-Kyung Kim; Hee Jung Moon; Jung Hyun Yoon; Vivian Y Park; Jin Young Kwak
Journal:  Endocrine       Date:  2017-05-15       Impact factor: 3.633

2.  The role of core needle biopsy in the diagnosis of initially detected thyroid nodules: a systematic review and meta-analysis.

Authors:  Sae Rom Chung; Chong Hyun Suh; Jung Hwan Baek; Young Jun Choi; Jeong Hyun Lee
Journal:  Eur Radiol       Date:  2018-05-22       Impact factor: 5.315

3.  Comparison of core-needle biopsy and repeat fine-needle aspiration for thyroid nodules with inconclusive initial cytology.

Authors:  Seon Min Jung; Hye Ryoung Koo; Ki Seok Jang; Min Sung Chung; Chang Myeon Song; Yong Bae Ji; Jeong Seon Park; Kyung Tae
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-11-16       Impact factor: 2.503

Review 4.  Complications following ultrasound-guided core needle biopsy of thyroid nodules: a systematic review and meta-analysis.

Authors:  Eun Ju Ha; Chong Hyun Suh; Jung Hwan Baek
Journal:  Eur Radiol       Date:  2018-03-27       Impact factor: 5.315

5.  Core-needle biopsy in thyroid nodules: performance, accuracy, and complications.

Authors:  Miguel Paja; Jose Luis Del Cura; Rosa Zabala; Igone Korta; Aitziber Ugalde; José I López
Journal:  Eur Radiol       Date:  2019-02-19       Impact factor: 5.315

6.  Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation.

Authors:  John Li; Zoe Weissberg; Thomas A Bevilacqua; Gordon Yu; Kristy Weber; Ronnie Sebro
Journal:  Radiol Med       Date:  2017-12-16       Impact factor: 3.469

7.  Cytopathologic criteria and size should be considered in comparison of fine-needle aspiration vs. core-needle biopsy for thyroid nodules: results based on large surgical series.

Authors:  Jung Hyun Yoon; Hye Sun Lee; Eun-Kyung Kim; Hee Jung Moon; Vivian Youngjean Park; Jin Young Kwak
Journal:  Endocrine       Date:  2020-07-12       Impact factor: 3.633

8.  Needle types used in abdominal cross-sectional interventional radiology: a survey of the Society of Abdominal Radiology emerging technology commission.

Authors:  Benjamin Wildman-Tobriner; Lisa M Ho; Andrew W Bowman
Journal:  Abdom Radiol (NY)       Date:  2021-06-14

9.  Efficacy and safety of core-needle biopsy in initially detected thyroid nodules via propensity score analysis.

Authors:  Chong Hyun Suh; Jung Hwan Baek; Young Jun Choi; Tae Yong Kim; Tae Yon Sung; Dong Eun Song; Jeong Hyun Lee
Journal:  Sci Rep       Date:  2017-08-15       Impact factor: 4.379

10.  High-Score US-Suspicious Subcentimeter Thyroid Nodules: What Factors Affect Adequate Sampling of US-Guided Fine-Needle Aspiration Biopsy?

Authors:  Yang Li; Jin Hong Yu; Ping Jie Du; Yu Xie; Sushant Kumar Das; Bing Li; Chuan Zhang
Journal:  Int J Endocrinol       Date:  2020-04-21       Impact factor: 3.257

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.