Literature DB >> 27245174

A new method for depth of interaction determination in PET detectors.

M Pizzichemi1, G Stringhini, T Niknejad, Z Liu, P Lecoq, S Tavernier, J Varela, M Paganoni, E Auffray.   

Abstract

A new method for obtaining depth of interaction (DOI) information in PET detectors is presented in this study, based on sharing and redirection of scintillation light among multiple detectors, together with attenuation of light over the length of the crystals. The aim is to obtain continuous DOI encoding with single side readout, and at the same time without the need for one-to-one coupling between scintillators and detectors, allowing the development of a PET scanner with good spatial, energy and timing resolutions while keeping the complexity of the system low. A prototype module has been produced and characterized to test the proposed method, coupling a LYSO scintillator matrix to a commercial SiPMs array. Excellent crystal separation is obtained for all the scintillators in the array, light loss due to depolishing is found to be negligible, energy resolution is shown to be on average 12.7% FWHM. The mean DOI resolution achieved is 4.1 mm FWHM on a 15 mm long crystal and preliminary coincidence time resolution was estimated in 353 ps FWHM.

Mesh:

Year:  2016        PMID: 27245174     DOI: 10.1088/0031-9155/61/12/4679

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  High-Resolution Depth-Encoding PET Detector Module with Prismatoid Light-Guide Array.

Authors:  Andy LaBella; Xinjie Cao; Eric Petersen; Rick Lubinsky; Anat Biegon; Wei Zhao; Amir H Goldan
Journal:  J Nucl Med       Date:  2020-02-28       Impact factor: 10.057

Review 2.  Advances in Preclinical PET.

Authors:  Stephen S Adler; Jurgen Seidel; Peter L Choyke
Journal:  Semin Nucl Med       Date:  2022-03-18       Impact factor: 4.802

Review 3.  Pitfalls on PET/CT Due to Artifacts and Instrumentation.

Authors:  Yu-Jung Tsai; Chi Liu
Journal:  Semin Nucl Med       Date:  2021-07-07       Impact factor: 4.446

Review 4.  Artificial intelligence with deep learning in nuclear medicine and radiology.

Authors:  Milan Decuyper; Jens Maebe; Roel Van Holen; Stefaan Vandenberghe
Journal:  EJNMMI Phys       Date:  2021-12-11

5.  High resolution detectors for whole-body PET scanners by using dual-ended readout.

Authors:  Zheng Liu; Ming Niu; Zhonghua Kuang; Ning Ren; San Wu; Longhan Cong; Xiaohui Wang; Ziru Sang; Crispin Williams; Yongfeng Yang
Journal:  EJNMMI Phys       Date:  2022-04-21

6.  Development and initial characterization of a high-resolution PET detector module with DOI.

Authors:  Mohan Li; Yuli Wang; Shiva Abbaszadeh
Journal:  Biomed Phys Eng Express       Date:  2020-10-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.