Literature DB >> 27239646

Comparison of three ultrasound based elastographic techniques in children and adolescents with chronic diffuse liver diseases.

Oana Belei1, Ioan Sporea2, Oana Gradinaru-Tascau2, Laura Olariu3, Alina Popescu2, Ioan Simedrea4, Otilia Marginean4.   

Abstract

UNLABELLED: Non-invasive techniques for liver fibrosis assessment were developed for adults and recent researches tested their accuracy in children. The only validated elastographic method for non-invasive liver fibrosis evaluation in children is Transient Elastography (TE). The aim of our study was to investigate the feasibility of liver stiffness (LS) measurement in paediatric patients with chronic liver diseases by means of Acoustic Radiation Force Impulse Elastography (ARFI) and 2D-Shear Wave Elastography (2D-SWE), compared to TE as reference method.
MATERIAL AND METHODS: We enrolled 54 consecutive children and adolescents with different chronic liver diseases. All patients were examined by means of TE, ARFI, and 2D-SWE. All measurements were performed in the right liver lobe, in the same session, in fasting condition. We considered reliable LS elastographic measurements as follows: for TE and ARFI - the median value of ten measurements with a success rate >/=60% and an interquartile range<30%, for 2D-SWE - the median value of five measurements.
RESULTS: The successful measurement rate for TE was 94.4% (51/54). Taking TE as a reference method, sensitivity of ARFI for detecting fibrosis F1 was 71.42%, for F2-77.77%, for F3-62.5% and for F4-71.42%. Sensitivity of 2D-SWE for detecting F1 was 92.85%, for F2-83.33%, for F3-87.5% and for F4-85.71%. We found significant correlations between TE and 2D-SWE on the entire lot (Kappa correlation factor=0.843, p=0.001). Analyzing the subgroup with SR=60%-70%, we did not find significant correlation between TE and ARFI (Kappa correlation factor=0.172, p=0.452). Assessing the subgroup with SR>70%, we found a significant correlation between TE and ARFI (Kappa correlation factor=0.761, p=0.001).
CONCLUSIONS: Overall, 2D-SWE correlate better with TE compared to ARFI in children. Excluding patients with less satisfactory technical parameters, we obtained significant correlations between all three methods. Both SWE and ARFI are non-invasive techniques feasible of performing on paediatric patients along with TE.

Entities:  

Mesh:

Year:  2016        PMID: 27239646     DOI: 10.11152/mu.2013.2066.182.bet

Source DB:  PubMed          Journal:  Med Ultrason        ISSN: 1844-4172            Impact factor:   1.611


  10 in total

1.  Hepatic shear wave elastography in children under free-breathing and breath-hold conditions.

Authors:  Caroline Jung; Michael Groth; Kay Uwe Petersen; Anna Hammel; Florian Brinkert; Enke Grabhorn; Sören Alexander Weidemann; Jasmin Busch; Gerhard Adam; Jochen Herrmann
Journal:  Eur Radiol       Date:  2017-06-20       Impact factor: 5.315

Review 2.  Imaging Modalities in Pediatric NAFLD.

Authors:  Suraj D Serai; Jennifer Panganiban; Manish Dhyani; Andrew J Degnan; Sudha A Anupindi
Journal:  Clin Liver Dis (Hoboken)       Date:  2021-04-13

3.  Technical performance of shear wave elastography for measuring liver stiffness in pediatric and adolescent patients: a systematic review and meta-analysis.

Authors:  Dong Wook Kim; Chan Park; Hee Mang Yoon; Ah Young Jung; Jin Seong Lee; Seung Chai Jung; Young Ah Cho
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

Review 4.  Advances in Diagnostic Imaging in Pediatric Gastroenterology.

Authors:  Jonathan Zember; Judyta Loomis; Pranav Vyas; Vahe Badalyan; Narendra Shet
Journal:  Curr Gastroenterol Rep       Date:  2020-03-19

5.  Diagnostic accuracy of two-dimensional shear wave elastography in detecting hepatic fibrosis in children with autoimmune hepatitis, biliary atresia and other chronic liver diseases.

Authors:  Paraskevi Galina; Efthymia Alexopoulou; Anastasia Mentessidou; Petros Mirilas; Aglaia Zellos; Lilia Lykopoulou; Amalia Patereli; Konstantinos Salpasaranis; Nikolaos L Kelekis; Maria Zarifi
Journal:  Pediatr Radiol       Date:  2021-03-23

Review 6.  The diagnostic performance of shear-wave elastography for liver fibrosis in children and adolescents: A systematic review and diagnostic meta-analysis.

Authors:  Jeong Rye Kim; Chong Hyun Suh; Hee Mang Yoon; Jin Seong Lee; Young Ah Cho; Ah Young Jung
Journal:  Eur Radiol       Date:  2017-10-10       Impact factor: 5.315

Review 7.  Limitations and opportunities of non-invasive liver stiffness measurement in children.

Authors:  Guido Engelmann; Jasmin Quader; Ulrike Teufel; Jens Peter Schenk
Journal:  World J Hepatol       Date:  2017-03-18

8.  Normal Liver Stiffness Values in Children: A Comparison of Three Different Elastography Methods.

Authors:  Anders B Mjelle; Anesa Mulabecirovic; Roald F Havre; Karen Rosendahl; Petur B Juliusson; Edda Olafsdottir; Odd H Gilja; Mette Vesterhus
Journal:  J Pediatr Gastroenterol Nutr       Date:  2019-05       Impact factor: 2.839

9.  The assessment of liver fibrosis in children with obesity on two methods: transient and two dimensional shear wave elastography.

Authors:  Cristina Oana Mărginean; Lorena Elena Meliţ; Dana Valentina Ghiga; Maria Oana Săsăran
Journal:  Sci Rep       Date:  2019-12-24       Impact factor: 4.379

10.  Noninvasive Pediatric Liver Fibrosis Measurement: Two-Dimensional Shear Wave Elastography Compared With Transient Elastography.

Authors:  Léa Chantal Tran; Delphine Ley; Gurvan Bourdon; Stéphanie Coopman; Héloïse Lerisson; Céline Tillaux; Hélène Béhal; Frédéric Gottrand; Madeleine Aumar
Journal:  Front Pediatr       Date:  2022-04-28       Impact factor: 3.418

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.