Literature DB >> 27238632

Double-gated myocardial ASL perfusion imaging is robust to heart rate variation.

Hung Phi Do1, Andrew J Yoon2, Michael W Fong2, Farhood Saremi3, Mark L Barr4, Krishna S Nayak5.   

Abstract

PURPOSE: Cardiac motion is a dominant source of physiological noise (PN) in myocardial arterial spin labeled (ASL) perfusion imaging. This study investigates the sensitivity to heart rate variation (HRV) of double-gated myocardial ASL compared with the more widely used single-gated method.
METHODS: Double-gating and single-gating were performed on 10 healthy volunteers (n = 10, 3F/7M; age, 23-34 years) and eight heart transplant recipients (n = 8, 1F/7M; age, 26-76 years) at rest in the randomized order. Myocardial blood flow (MBF), PN, temporal signal-to-noise ratio (SNR), and HRV were measured.
RESULTS: HRV ranged from 0.2 to 7.8 bpm. Double-gating PN did not depend on HRV, while single-gating PN increased with HRV. Over all subjects, double-gating provided a significant reduction in global PN (from 0.20 ± 0.15 to 0.11 ± 0.03 mL/g/min; P = 0.01) and per-segment PN (from 0.33 ± 0.23 to 0.21 ± 0.12 mL/g/min; P < 0.001), with significant increases in global temporal SNR (from 11 ± 8 to 18 ± 8; P = 0.02) and per-segment temporal SNR (from 7 ± 4 to 11 ± 12; P < 0.001) without significant difference in measured MBF.
CONCLUSION: Single-gated myocardial ASL suffers from reduced temporal SNR, while double-gated myocardial ASL provides consistent temporal SNR independent of HRV. Magn Reson Med 77:1975-1980, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  arterial spin labeling; cardiovascular magnetic resonance; heart rate variation; myocardial blood flow; myocardial perfusion imaging; physiological noise

Mesh:

Substances:

Year:  2016        PMID: 27238632     DOI: 10.1002/mrm.26282

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Accuracy, uncertainty, and adaptability of automatic myocardial ASL segmentation using deep CNN.

Authors:  Hung P Do; Yi Guo; Andrew J Yoon; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-11-14       Impact factor: 4.668

2.  Free-breathing 3D cardiac T1 mapping with transmit B1 correction at 3T.

Authors:  Paul Kyu Han; Thibault Marin; Yanis Djebra; Vanessa Landes; Yue Zhuo; Georges El Fakhri; Chao Ma
Journal:  Magn Reson Med       Date:  2021-11-23       Impact factor: 4.668

3.  Feasibility of coronary endothelial function assessment using arterial spin labeled CMR.

Authors:  Ahsan Javed; Andrew Yoon; Steven Cen; Krishna S Nayak; Parveen Garg
Journal:  NMR Biomed       Date:  2019-12-04       Impact factor: 4.044

4.  Non-contrast assessment of microvascular integrity using arterial spin labeled cardiovascular magnetic resonance in a porcine model of acute myocardial infarction.

Authors:  Hung P Do; Venkat Ramanan; Xiuling Qi; Jennifer Barry; Graham A Wright; Nilesh R Ghugre; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2018-07-02       Impact factor: 5.364

5.  Non-contrast myocardial perfusion in rest and exercise stress using systolic flow-sensitive alternating inversion recovery.

Authors:  Markus Henningsson; Carl-Johan Carlhäll; Tino Ebbers; Johan Kihlberg
Journal:  MAGMA       Date:  2021-12-27       Impact factor: 2.533

6.  Myocardial arterial spin labeling in systole and diastole using flow-sensitive alternating inversion recovery with parallel imaging and compressed sensing.

Authors:  Markus Henningsson; Carl-Johan Carlhäll; Johan Kihlberg
Journal:  NMR Biomed       Date:  2020-11-04       Impact factor: 4.478

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.