Literature DB >> 27235181

Accuracy of Different Modalities to Record Natural Head Position in 3 Dimensions: A Systematic Review.

Ming Yin Leung1, John Lo2, Yiu Yan Leung3.   

Abstract

PURPOSE: Three-dimensional (3D) images are taken with positioning devices to ensure a patient's stability, which, however, place the patient's head into a random orientation. Reorientation of images to the natural head position (NHP) is necessary for appropriate assessment of dentofacial deformities before any surgical planning. The aim of this study was to review the literature systematically to identify and evaluate the various modalities available to record the NHP in 3 dimensions and to compare their accuracy.
MATERIALS AND METHODS: A systematic literature search of the PubMed, Cochrane Library and Embase databases, with no limitations on publication time or language, was performed in July 2015. The search and evaluations of articles were performed in 4 rounds. The methodologies, accuracies, advantages, and limitations of various modalities to record NHP were examined.
RESULTS: Eight articles were included in the final review. Six modalities to record NHP were identified, namely 1) stereophotogrammetry, 2) facial markings along laser lines, 3) clinical photographs and the pose from orthography and scaling with iterations (POSIT) algorithm, 4) digital orientation sensing, 5) handheld 3D camera measuring system, and 6) laser scanning. Digital orientation sensing had good accuracy, with mean angular differences from the reference within 1° (0.07 ± 0.49° and 0.12 ± 0.54°, respectively). Laser scanning was shown to be comparable to digital orientation sensing. The method involving clinical photographs and the POSIT algorithm was reported to have good accuracy, with mean angular differences for pitch, roll, and yaw within 1° (-0.17 ± 0.50°). Stereophotogrammetry was reported to have the highest reliability, with mean angular deviations in pitch, roll, and yaw for active and passive stereophotogrammetric devices within 0.1° (0.004771 ± 0.045645° and 0.007572 ± 0.079088°, respectively).
CONCLUSIONS: This systematic review showed that recording the NHP in 3 dimensions with a digital orientation sensor has good accuracy. Laser scanning was found to have comparable accuracy to digital orientation sensing, but routine clinical use was limited by its high cost and low portability. Stereophotogrammetry and the method using a single clinical photograph and the POSIT algorithm were potential alternatives. Nevertheless, clinical trials are needed to verify their applications in patients. Preferably, digital orientation sensor should be used as a reference for comparison with new proposed methods of recording the NHP in future research.
Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27235181     DOI: 10.1016/j.joms.2016.04.022

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  6 in total

1.  There is variability in our perception of the standard head orientation.

Authors:  G N Hughes; J Gateño; J D English; J F Teichgraeber; J J Xia
Journal:  Int J Oral Maxillofac Surg       Date:  2017-05-15       Impact factor: 2.789

2.  Different Modalities to Record and Transfer Natural Head Position to Virtual Planning in Orthognathic Surgery: Case Reports of Asymmetric Patients.

Authors:  Maurício Silva Demétrio; Daniel Amaral Alves Marlière; Saulo de Matos Barbosa; Rodrigo Alvitos Pereira; Henrique Martins da Silveira
Journal:  J Maxillofac Oral Surg       Date:  2020-04-28

3.  An evaluation of three-dimensional facial changes after surgically assisted rapid maxillary expansion (SARME): an observational study.

Authors:  Jurij Zupan; Nataša Ihan Hren; Miha Verdenik
Journal:  BMC Oral Health       Date:  2022-05-02       Impact factor: 3.747

4.  Recording Natural Head Position Using Cone Beam Computerized Tomography.

Authors:  Tai-Chiu Hsung; Wai-Kan Yeung; Wing-Shan Choi; Wai-Kuen Luk; Yi-Yung Cheng; Yu-Hang Lam
Journal:  Sensors (Basel)       Date:  2021-12-08       Impact factor: 3.576

5.  Evaluation of head posture using an inertial measurement unit.

Authors:  Mustafa Al-Yassary; Kelly Billiaert; Gregory S Antonarakis; Stavros Kiliaridis
Journal:  Sci Rep       Date:  2021-10-07       Impact factor: 4.379

6.  Measuring the difference in natural head position between the standing and sitting positions using an inertial measurement unit.

Authors:  Kelly Billiaert; Mustafa Al-Yassary; Gregory S Antonarakis; Stavros Kiliaridis
Journal:  J Oral Rehabil       Date:  2021-08-11       Impact factor: 3.558

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.