Literature DB >> 27212120

Indwelling and Retrieval Complications of Denali and Celect Infrarenal Vena Cava Filters.

Aaron S Bos1, Thomas Tullius2, Mikin Patel2, Jeffrey A Leef2, Rakesh Navuluri2, Jonathan M Lorenz2, Thuong G Van Ha2.   

Abstract

PURPOSE: To compare indwelling and retrieval complications of Denali and Celect filters placed in the infrarenal inferior vena cava (IVC).
MATERIALS AND METHODS: A retrospective study was conducted over 2 years at a single institution in which 171 Denali and 162 Celect filters were placed in 333 patients with a mean age of 62.3 years ± 15.7 (161 men; 48.3%). Filter indications included venous thromboembolic disease (n = 320; 96.1%) and surgical prophylaxis (n = 13; 3.9%). A jugular approach was used to place 303 filters (91.0%). Computed tomography (CT) follow-up, complications, and retrieval data were obtained.
RESULTS: Follow-up CT imaging was performed on 58 filters from each group with lower incidences of caval strut penetration (one vs 12) and filter tilt (one vs 15) in the Denali filter group (P = .002 and P < .001, respectively). There was no difference in incidences of breakthrough pulmonary embolism (P = .68). Retrieval attempts were performed on 43 Denali and 53 Celect filters with mean indwelling times at retrieval of 128.2 and 144.1 days, respectively (P = .40). Mean fluoroscopy time at retrieval was lower in the Denali group (3.1 min vs 6.0 min; P = .01). There were fewer cases of complex retrieval in the Denali group (n = 2 vs 10; P = .06). Tilt, fluoroscopy time, and air kerma were associated with complex retrieval (P = .04, P < .001, and P < .001, respectively). There was one Denali filter deployment complication that led to retrieval failure.
CONCLUSIONS: This study suggests that Denali filters are associated with lower incidences of strut penetration and filter tilt as well as shorter fluoroscopy time at retrieval compared with Celect filters when placed in the infrarenal IVC.
Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27212120     DOI: 10.1016/j.jvir.2016.03.034

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  4 in total

1.  An analysis of factors associated with increased fluoroscopy time or the need for complex techniques at IVC filter retrieval.

Authors:  Mark Kleedehn; Kelli Moore; Katherine Longo; Kaitlin Woo; Paul Laeseke
Journal:  Eur Radiol       Date:  2018-10-09       Impact factor: 5.315

2.  Filter tilting and retrievability of the Celect and Denali inferior vena cava filters using propensity score-matching analysis.

Authors:  Jae Heung Bae; Sang Yub Lee
Journal:  Eur J Radiol Open       Date:  2018-09-10

3.  A Rare Case of Idiopathic Gonadal Vein Thrombosis.

Authors:  Hany A Zaki; Haris Iftikhar; Ahmed E Shaban; Omar Khyatt; Eman E Shaban
Journal:  Cureus       Date:  2022-01-17

Review 4.  Procedural complications of inferior vena cava filter retrieval, an illustrated review.

Authors:  Keith B Quencer; Tyler A Smith; Amy Deipolyi; Hamid Mojibian; Raj Ayyagari; Igor Latich; Rahmat Ali
Journal:  CVIR Endovasc       Date:  2020-04-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.