Non-invasive monitoring of pulmonary artery pressure from timing information by EIT: experimental evaluation during induced hypoxia.

Martin Proença1, Fabian Braun, Josep Solà, Andy Adler, Mathieu Lemay, Jean-Philippe Thiran, Stefano F Rimoldi.   

Abstract

Monitoring of pulmonary artery pressure (PAP) in pulmonary hypertensive patients is currently limited to invasive solutions. We investigate a novel non-invasive approach for continuous monitoring of PAP, based on electrical impedance tomography (EIT), a safe, low-cost and non-invasive imaging technology. EIT recordings were performed in three healthy subjects undergoing hypoxia-induced PAP variations. The pulmonary pulse arrival time (PAT), a timing parameter physiologically linked to the PAP, was automatically calculated from the EIT signals. Values were compared to systolic PAP values from Doppler echocardiography, and yielded strong correlation scores ([Formula: see text]) for all three subjects. Results suggest the feasibility of non-invasive, unsupervised monitoring of PAP.

Entities:  

Mesh:

Year:  2016        PMID: 27212013     DOI: 10.1088/0967-3334/37/6/713

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Computational Fluid Dynamics Modeling of the Human Pulmonary Arteries with Experimental Validation.

Authors:  Alifer D Bordones; Matthew Leroux; Vitaly O Kheyfets; Yu-An Wu; Chia-Yuan Chen; Ender A Finol
Journal:  Ann Biomed Eng       Date:  2018-05-21       Impact factor: 3.934

2.  The first study comparing a wearable watch-type blood pressure monitor with a conventional ambulatory blood pressure monitor on in-office and out-of-office settings.

Authors:  Kazuomi Kario; Daichi Shimbo; Naoko Tomitani; Hiroshi Kanegae; Joseph E Schwartz; Bryan Williams
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-01-19       Impact factor: 3.738

3.  Non-invasive pulmonary artery pressure estimation by electrical impedance tomography in a controlled hypoxemia study in healthy subjects.

Authors:  Martin Proença; Fabian Braun; Mathieu Lemay; Josep Solà; Andy Adler; Thomas Riedel; Franz H Messerli; Jean-Philippe Thiran; Stefano F Rimoldi; Emrush Rexhaj
Journal:  Sci Rep       Date:  2020-12-08       Impact factor: 4.379

4.  Electrical impedance tomography in pulmonary arterial hypertension.

Authors:  André L D Hovnanian; Eduardo L V Costa; Susana Hoette; Caio J C S Fernandes; Carlos V P Jardim; Bruno A Dias; Luciana T K Morinaga; Marcelo B P Amato; Rogério Souza
Journal:  PLoS One       Date:  2021-03-17       Impact factor: 3.240

5.  Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers.

Authors:  Fabian Braun; Martin Proença; Andy Adler; Thomas Riedel; Jean-Philippe Thiran; Josep Solà
Journal:  PLoS One       Date:  2018-01-26       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.