The effect of dynamic hip motion on the micromotion of press-fit acetabular cups in six degrees of freedom.

Emilie A Crosnier1, Patrick S Keogh2, Anthony W Miles3.   

Abstract

The hip joint is subjected to cyclic loading and motion during activities of daily living and this can induce micromotions at the bone-implant interface of cementless total hip replacements. Initial stability has been identified as a crucial factor to achieve osseointegration and long-term survival. Whilst fixation of femoral stems achieves good clinical results, the fixation of acetabular components remains a challenge. In vitro methods assessing cup stability keep the hip joint in a fixed position, overlooking the effect of hip motion. The effect of hip motion on cup micromotion using a hip motion simulator replicating hip flexion-extension and a six degrees of freedom measurement system was investigated. The results show an increase in cup micromotion under dynamic hip motion compared to Static Flexion. This highlights the need to incorporate hip motion and measure all degrees of freedom when assessing cup micromotion. In addition, comparison of two press-fit acetabular cups with different surface coatings suggested similar stability between the two cups. This new method provides a basis for a more representative protocol for future pre-clinical evaluation of different cup designs.
Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

Keywords:  Acetabular cups; Biomechanical study; Initial stability; Press-fit fixation; Total hip replacement

Mesh:

Year:  2016        PMID: 27210567     DOI: 10.1016/j.medengphy.2016.04.014

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  Impaction technique influences implant stability in low-density bone model.

Authors:  Ruben Doyle; Richard J van Arkel; Sarah Muirhead-Allwood; Jonathan R T Jeffers
Journal:  Bone Joint Res       Date:  2020-07-31       Impact factor: 5.853

2.  Two Different Methods to Measure the Stability of Acetabular Implants: A Comparison Using Artificial Acetabular Models.

Authors:  Quentin Goossens; Leonard Cezar Pastrav; Michiel Mulier; Wim Desmet; Jos Vander Sloten; Kathleen Denis
Journal:  Sensors (Basel)       Date:  2020-01-01       Impact factor: 3.576

3.  Effect of impaction energy on dynamic bone strains, fixation strength, and seating of cementless acetabular cups.

Authors:  Ruben Doyle; Richard J van Arkel; Jonathan R T Jeffers
Journal:  J Orthop Res       Date:  2019-08-02       Impact factor: 3.494

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.