Literature DB >> 21077242

Feasibility of SU-8-based capillary electrophoresis-electrospray ionization mass spectrometry microfluidic chips for the analysis of human cell lysates.

Nina Nordman1, Tiina Sikanen, Susanna Aura, Santeri Tuomikoski, Katariina Vuorensola, Tapio Kotiaho, Sami Franssila, Risto Kostiainen.   

Abstract

Monolithically integrated, polymer (SU-8) microchips comprising an electrophoretic separation unit, a sheath flow interface and an ESI emitter were developed to improve the speed and throughput of proteomics analyses. Validation of the microchip method was performed based on peptide mass fingerprinting and single peptide sequencing of selected protein standards. Rapid, yet reliable identification of four biologically important proteins (cytochrome C, β-lactoglobulin, ovalbumin and BSA) confirmed the applicability of the SU-8 microchips to ambitious proteomic applications and allowed their use in the analysis of human muscle cell lysates. The characteristic tryptic peptides were easily separated with plate numbers approaching 10(6), and with peak widths at half height as low as 0.6 s. The on-chip sheath flow interface was also exploited to the introduction of an internal mass calibrant along with the sheath liquid which enabled accurate mass measurements by high-resolution Q-TOF MS. Additionally, peptide structural characterization and protein identification based on MS/MS fragmentation data of a single tryptic peptide was obtained using an ion trap instrument. Protein sequence coverages exceeding 50% were routinely obtained without any pretreatment of the proteolytic samples and a typical total analysis time from sampling to detection was well below ten minutes. In conclusion, monolithically integrated, dead-volume-free, SU-8 microchips proved to be a promising platform for fast and reliable analysis of complex proteomic samples. Good analytical performance of the microchips was shown by performing both peptide mass fingerprinting of complex cell lysates and protein identification based on single peptide sequencing.
Copyright © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21077242     DOI: 10.1002/elps.201000373

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  6 in total

Review 1.  Microfluidics-to-mass spectrometry: a review of coupling methods and applications.

Authors:  Xue Wang; Lian Yi; Nikita Mukhitov; Adrian M Schrell; Raghuram Dhumpa; Michael G Roper
Journal:  J Chromatogr A       Date:  2014-10-23       Impact factor: 4.759

2.  Epoxy insulated carbon fiber and carbon nanotube fiber microelectrodes.

Authors:  Alexander G Zestos; Michael D Nguyen; Brian L Poe; Christopher B Jacobs; B Jill Venton
Journal:  Sens Actuators B Chem       Date:  2013-03-27       Impact factor: 7.460

Review 3.  Chemical analysis of single cells.

Authors:  Yuqing Lin; Raphaël Trouillon; Gulnara Safina; Andrew G Ewing
Journal:  Anal Chem       Date:  2011-04-28       Impact factor: 6.986

4.  A microchip electrophoresis-mass spectrometric platform with double cell lysis nano-electrodes for automated single cell analysis.

Authors:  Xiangtang Li; Shulin Zhao; Hankun Hu; Yi-Ming Liu
Journal:  J Chromatogr A       Date:  2016-05-06       Impact factor: 4.759

5.  Fast quantification of amino acids by microchip electrophoresis-mass spectrometry.

Authors:  Xiangtang Li; Dan Xiao; Talia Sanders; Paul B Tchounwou; Yi-Ming Liu
Journal:  Anal Bioanal Chem       Date:  2013-08-09       Impact factor: 4.142

6.  On-line pre-treatment, separation, and nanoelectrospray mass spectrometric determinations for pesticide metabolites and peptides based on a modular microfluidic platform.

Authors:  Yinyin Hao; Yajing Bao; Xueying Huang; Yijun Hu; Bo Xiong
Journal:  RSC Adv       Date:  2018-11-28       Impact factor: 3.361

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.