Literature DB >> 27203864

Biologically optimized helium ion plans: calculation approach and its in vitro validation.

A Mairani1, I Dokic, G Magro, T Tessonnier, F Kamp, D J Carlson, M Ciocca, F Cerutti, P R Sala, A Ferrari, T T Böhlen, O Jäkel, K Parodi, J Debus, A Abdollahi, T Haberer.   

Abstract

Treatment planning studies on the biological effect of raster-scanned helium ion beams should be performed, together with their experimental verification, before their clinical application at the Heidelberg Ion Beam Therapy Center (HIT). For this purpose, we introduce a novel calculation approach based on integrating data-driven biological models in our Monte Carlo treatment planning (MCTP) tool. Dealing with a mixed radiation field, the biological effect of the primary (4)He ion beams, of the secondary (3)He and (4)He (Z  =  2) fragments and of the produced protons, deuterons and tritons (Z  =  1) has to be taken into account. A spread-out Bragg peak (SOBP) in water, representative of a clinically-relevant scenario, has been biologically optimized with the MCTP and then delivered at HIT. Predictions of cell survival and RBE for a tumor cell line, characterized by [Formula: see text] Gy, have been successfully compared against measured clonogenic survival data. The mean absolute survival variation ([Formula: see text]) between model predictions and experimental data was 5.3%  ±  0.9%. A sensitivity study, i.e. quantifying the variation of the estimations for the studied plan as a function of the applied phenomenological modelling approach, has been performed. The feasibility of a simpler biological modelling based on dose-averaged LET (linear energy transfer) has been tested. Moreover, comparisons with biophysical models such as the local effect model (LEM) and the repair-misrepair-fixation (RMF) model were performed. [Formula: see text] values for the LEM and the RMF model were, respectively, 4.5%  ±  0.8% and 5.8%  ±  1.1%. The satisfactorily agreement found in this work for the studied SOBP, representative of clinically-relevant scenario, suggests that the introduced approach could be applied for an accurate estimation of the biological effect for helium ion radiotherapy.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27203864     DOI: 10.1088/0031-9155/61/11/4283

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  The accuracy of helium ion CT based particle therapy range prediction: an experimental study comparing different particle and x-ray CT modalities.

Authors:  L Volz; C-A Collins-Fekete; E Bär; S Brons; C Graeff; R P Johnson; A Runz; C Sarosiek; R W Schulte; J Seco
Journal:  Phys Med Biol       Date:  2021-11-29       Impact factor: 3.609

2.  The impact of secondary fragments on the image quality of helium ion imaging.

Authors:  Lennart Volz; Pierluigi Piersimoni; Vladimir A Bashkirov; Stephan Brons; Charles-Antoine Collins-Fekete; Robert P Johnson; Reinhard W Schulte; Joao Seco
Journal:  Phys Med Biol       Date:  2018-10-02       Impact factor: 3.609

3.  Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison.

Authors:  Thomas Tessonnier; Andrea Mairani; Wenjing Chen; Paola Sala; Francesco Cerutti; Alfredo Ferrari; Thomas Haberer; Jürgen Debus; Katia Parodi
Journal:  Radiat Oncol       Date:  2018-01-09       Impact factor: 3.481

4.  Mechanistic Modeling of the Relative Biological Effectiveness of Boron Neutron Capture Therapy.

Authors:  Seth W Streitmatter; Robert D Stewart; Gregory Moffitt; Tatjana Jevremovic
Journal:  Cells       Date:  2020-10-15       Impact factor: 6.600

5.  The Effect of Hypoxia on Relative Biological Effectiveness and Oxygen Enhancement Ratio for Cells Irradiated with Grenz Rays.

Authors:  Chun-Chieh Chan; Fang-Hsin Chen; Kuang-Lung Hsueh; Ya-Yun Hsiao
Journal:  Cancers (Basel)       Date:  2022-02-28       Impact factor: 6.639

6.  Biological effectiveness and relative biological effectiveness of ion beams for in-vitro cell irradiation.

Authors:  Heng Li
Journal:  Cancer Sci       Date:  2022-06-20       Impact factor: 6.518

7.  Fast robust dose calculation on GPU for high-precision 1H, 4He, 12C and 16O ion therapy: the FRoG platform.

Authors:  Stewart Mein; Kyungdon Choi; Benedikt Kopp; Thomas Tessonnier; Julia Bauer; Alfredo Ferrari; Thomas Haberer; Jürgen Debus; Amir Abdollahi; Andrea Mairani
Journal:  Sci Rep       Date:  2018-10-04       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.