Literature DB >> 27203154

Electrical impedance tomography in 3D using two electrode planes: characterization and evaluation.

Justin Wagenaar1, Andy Adler.   

Abstract

Electrical impedance tomography (EIT) uses body surface electrical stimulation and measurements to create conductivity images; it shows promise as a non-invasive technology to monitor the distribution of lung ventilation. Most applications of EIT have placed electrodes in a 2D ring around the thorax, and thus produced 2D cross-sectional images. These images are unable to distinguish out-of-plane contributions, or to image volumetric effects. Volumetric EIT can be calculated using multiple electrode planes and a 3D reconstruction algorithm. However, while 3D reconstruction algorithms are available, little has been done to understand the performance of 3D EIT in terms of the measurement configurations available. The goal of this paper is to characterize the phantom and in vivo performance of 3D EIT with two electrode planes. First, phantom measurements are used to measure the reconstruction characteristics of seven stimulation and measurement configurations. Measurements were then performed on eight healthy volunteers as a function of body posture, postures, and with various electrode configurations. Phantom results indicate that 3D EIT using two rings of electrodes provides reasonable resolution in the electrode plane but low vertical resolution. For volunteers, functional EIT images are created from inhalation curve features to analyze the effect of posture (standing, sitting, supine and decline) on regional lung behaviour. An ability to detect vertical changes in lung volume distribution was shown for two electrode configurations. Based on tank and volunteer results, we recommend the use of the 'square' stimulation and measurement pattern for two electrode plane EIT.

Mesh:

Year:  2016        PMID: 27203154     DOI: 10.1088/0967-3334/37/6/922

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Optimization of the electrode drive pattern for imaging fascicular compound action potentials in peripheral nerve with fast neural electrical impedance tomography.

Authors:  Enrico Ravagli; Svetlana Mastitskaya; Nicole Thompson; Kirill Aristovich; David Holder
Journal:  Physiol Meas       Date:  2019-12-03       Impact factor: 2.833

Review 2.  Assessment of Heterogeneity in Lung Structure and Function During Mechanical Ventilation: A Review of Methodologies.

Authors:  Jacob Herrmann; Michaela Kollisch-Singule; Joshua Satalin; Gary F Nieman; David W Kaczka
Journal:  J Eng Sci Med Diagn Ther       Date:  2022-05-11

3.  Three-dimensional Pulmonary Monitoring Using Focused Electrical Impedance Measurements.

Authors:  Jakob Orschulik; Diana Pokee; Tobias Menden; Steffen Leonhardt; Marian Walter
Journal:  J Electr Bioimpedance       Date:  2018-12-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.