Literature DB >> 27196026

Effect of Polyether Ether Ketone on Therapeutic Radiation to the Spine: A Pilot Study.

J Benjamin Jackson1, Anthony J Crimaldi2, Richard Peindl3, H James Norton4, William E Anderson4, Joshua C Patt5.   

Abstract

STUDY
DESIGN: Cadaveric model.
OBJECTIVES: To compare the effect of PEEK versus conventional implants on scatter radiation to a simulated tumor bed in the spine SUMMARY OF BACKGROUND DATA.: Given the highly vasculature nature of the spine, it is the most common place for bony metastases. After surgical treatment of a spinal metastasis, adjuvant radiation therapy is typically administered. Radiation dosing is primarily limited by toxicity to the spinal cord. The scatter effect caused by metallic implants decreases the accuracy of dosing and can unintentionally increase the effective dose seen by the spinal cord. This represents a dose-limiting factor for therapeutic radiation postoperatively.
METHODS: A cadaveric thorax specimen was utilized as a metastatic tumor model with two separate three-level spine constructs (one upper thoracic and one lower thoracic). Each construct was examined independently. All four groups compared included identical posterior instrumentation. The anterior constructs consisted of either: an anterior polyether ether ketone (PEEK) cage, an anterior titanium cage, an anterior bone cement cage (polymethyl methacrylate), or a control group with posterior instrumentation alone. Each construct had six thermoluminescent detectors to measure the radiation dose.
RESULTS: The mean dose was similar across all constructs and locations. There was more variability in the upper thoracic spine irrespective of the construct type. The PEEK construct had a more uniform dose distribution with a standard deviation of 9.76. The standard deviation of the others constructs was 14.26 for the control group, 19.31 for the titanium cage, and 21.57 for the cement (polymethyl methacrylate) construct.
CONCLUSION: The PEEK inter-body cage resulted in a significantly more uniform distribution of therapeutic radiation in the spine when compared with the other constructs. This may allow for the application of higher effective dosing to the tumor bed for spinal metastases without increasing spinal cord toxicity with either fractionated or hypofractionated radiotherapy. LEVEL OF EVIDENCE: N/A.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27196026     DOI: 10.1097/BRS.0000000000001695

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  8 in total

1.  Safety and utility of kyphoplasty prior to spine stereotactic radiosurgery for metastatic tumors: a clinical and dosimetric analysis.

Authors:  Ori Barzilai; Natalie DiStefano; Eric Lis; Yoshiya Yamada; D Michael Lovelock; Andrew N Fontanella; Mark H Bilsky; Ilya Laufer
Journal:  J Neurosurg Spine       Date:  2017-11-03

2.  Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report.

Authors:  Stefano Boriani; Giuseppe Tedesco; Lu Ming; Riccardo Ghermandi; Maurizio Amichetti; Piero Fossati; Marco Krengli; Loredana Mavilla; Alessandro Gasbarrini
Journal:  Eur Spine J       Date:  2017-08-16       Impact factor: 3.134

3.  Multidisciplinary Approach to Patients With Metastatic Spinal Cord Compression: A Diagnostic Therapeutic Algorithm to Improve the Neurological Outcome.

Authors:  Rossella Rispoli; Chiara Reverberi; Giada Targato; Serena D'Agostini; Gianpiero Fasola; Marco Trovò; Mario Calci; Renato Fanin; Barbara Cappelletto
Journal:  Front Oncol       Date:  2022-06-07       Impact factor: 5.738

Review 4.  Separation surgery for metastatic epidural spinal cord compression: A qualitative review.

Authors:  Giuseppe Di Perna; Fabio Cofano; Cristina Mantovani; Serena Badellino; Nicola Marengo; Marco Ajello; Ludovico Maria Comite; Giuseppe Palmieri; Fulvio Tartara; Francesco Zenga; Umberto Ricardi; Diego Garbossa
Journal:  J Bone Oncol       Date:  2020-09-26       Impact factor: 4.072

5.  First Clinical Experience with a Carbon Fibre Reinforced PEEK Composite Plating System for Anterior Cervical Discectomy and Fusion.

Authors:  Helena Milavec; Christoph Kellner; Nivetha Ravikumar; Christoph E Albers; Till Lerch; Sven Hoppe; Moritz C Deml; Sebastian F Bigdon; Naresh Kumar; Lorin M Benneker
Journal:  J Funct Biomater       Date:  2019-07-02

6.  Attitudes and trends in the use of radiolucent spinal implants: A survey of the North American Spine Society section of spinal oncology.

Authors:  Athan G Zavras; Andrew J Schoenfeld; Joshua C Patt; Mohammed A Munim; C Rory Goodwin; Matthew L Goodwin; Sheng-Fu Larry Lo; Kristin J Redmond; Daniel G Tobert; John H Shin; Marco L Ferrone; Ilya Laufer; Comron Saifi; Jacob M Buchowski; Jack W Jennings; Ali K Ozturk; Christina Huang-Wright; Addisu Mesfin; Chris Steyn; Wesley Hsu; Hesham M Soliman; Ajit A Krishnaney; Daniel M Sciubba; Joseph H Schwab; Matthew W Colman
Journal:  N Am Spine Soc J       Date:  2022-02-23

7.  Lumbar Fusion With Polyetheretherketone Rods Use for Patients With Degenerative Disease.

Authors:  Donald A Ross; Miner N Ross
Journal:  Fed Pract       Date:  2021-04

Review 8.  An Overview of Decision Making in the Management of Metastatic Spinal Tumors.

Authors:  Gautam R Zaveri; Reetu Jain; Nishank Mehta; Bhavuk Garg
Journal:  Indian J Orthop       Date:  2021-03-06       Impact factor: 1.251

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.