Literature DB >> 27170897

Development of Point of Care Testing Device for Neurovascular Coupling From Simultaneous Recording of EEG and NIRS During Anodal Transcranial Direct Current Stimulation.

Utkarsh Jindal, Mehak Sood, Anirban Dutta, Shubhajit Roy Chowdhury.   

Abstract

This paper presents a point of care testing device for neurovascular coupling (NVC) from simultaneous recording of electroencephalogram (EEG) and near infrared spectroscopy (NIRS) during anodal transcranial direct current stimulation (tDCS). Here, anodal tDCS modulated cortical neural activity leading to hemodynamic response can be used to identify the impaired cerebral microvessels functionality. The impairments in the cerebral microvessels functionality may lead to impairments in the cerebrovascular reactivity (CVR), where severely reduced CVR predicts the chances of transient ischemic attack and ipsilateral stroke. The neural and hemodynamic responses to anodal tDCS were studied through joint imaging with EEG and NIRS, where NIRS provided optical measurement of changes in tissue oxy-([Formula: see text] and deoxy-([Formula: see text]) hemoglobin concentration and EEG captured alterations in the underlying neuronal current generators. Then, a cross-correlation method for the assessment of NVC underlying the site of anodal tDCS is presented. The feasibility studies on healthy subjects and stroke survivors showed detectable changes in the EEG and the NIRS responses to a 0.526 A/[Formula: see text] of anodal tDCS. The NIRS system was bench tested on 15 healthy subjects that showed a statistically significant (p < 0.01) difference in the signal-to-noise ratio (SNR) between the ON- and OFF-states of anodal tDCS where the mean SNR of the NIRS device was found to be 42.33 ± 1.33 dB in the ON-state and 40.67 ± 1.23 dB in the OFF-state. Moreover, the clinical study conducted on 14 stroke survivors revealed that the lesioned hemisphere with impaired circulation showed significantly (p < 0.01) less change in [Formula: see text] than the nonlesioned side in response to anodal tDCS. The EEG study on healthy subjects showed a statistically significant (p < 0.05) decrease around individual alpha frequency in the alpha band (8-13 Hz) following anodal tDCS. Moreover, the joint EEG-NIRS imaging on 4 stroke survivors showed an immediate increase in the theta band (4-8 Hz) EEG activity after the start of anodal tDCS at the nonlesioned hemisphere. Furthermore, cross-correlation function revealed a significant (95% confidence interval) negative cross correlation only at the nonlesioned hemisphere during anodal tDCS, where the log-transformed mean-power of EEG within 0.5-11.25 Hz lagged [Formula: see text] response in one of the stroke survivors with white matter lesions. Therefore, it was concluded that the anodal tDCS can perturb the local neural and the vascular activity (via NVC) which can be used for assessing regional NVC functionality where confirmatory clinical studies are required.

Entities:  

Keywords:  Electroencephalogram; Hilbert-Huang transform; near infrared spectroscopy; neurovascular coupling; small vessel diseases; stroke; transcranial direct current stimulation

Year:  2015        PMID: 27170897      PMCID: PMC4848058          DOI: 10.1109/JTEHM.2015.2389230

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  48 in total

1.  A programmable laboratory testbed in support of evaluation of functional brain activation and connectivity.

Authors:  Randall L Barbour; Harry L Graber; Yong Xu; Yaling Pei; Christoph H Schmitz; Douglas S Pfeil; Anandita Tyagi; Randy Andronica; Daniel C Lee; San-Lian S Barbour; J David Nichols; Mark E Pflieger
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2012-03       Impact factor: 3.802

2.  Time-gated optical system for depth-resolved functional brain imaging.

Authors:  Juliette Selb; Danny K Joseph; David A Boas
Journal:  J Biomed Opt       Date:  2006 Jul-Aug       Impact factor: 3.170

3.  Neurometabolic coupling in cerebral cortex reflects synaptic more than spiking activity.

Authors:  Ahalya Viswanathan; Ralph D Freeman
Journal:  Nat Neurosci       Date:  2007-09-09       Impact factor: 24.884

4.  Cerebrovascular reactivity measured by near-infrared spectroscopy.

Authors:  Jennifer K Lee; Kathleen K Kibler; Paul B Benni; R Blaine Easley; Marek Czosnyka; Peter Smielewski; Raymond C Koehler; Donald H Shaffner; Ken M Brady
Journal:  Stroke       Date:  2009-03-12       Impact factor: 7.914

Review 5.  Non-invasive optical spectroscopy and imaging of human brain function.

Authors:  A Villringer; B Chance
Journal:  Trends Neurosci       Date:  1997-10       Impact factor: 13.837

Review 6.  Topographic EEG in brain ischemia--correlation with blood flow and metabolism.

Authors:  K Nagata
Journal:  Brain Topogr       Date:  1988       Impact factor: 3.020

7.  Transcranial direct current stimulation induces polarity-specific changes of cortical blood perfusion in the rat.

Authors:  Dorothee Wachter; Arne Wrede; Walter Schulz-Schaeffer; Ali Taghizadeh-Waghefi; Michael A Nitsche; Anna Kutschenko; Veit Rohde; David Liebetanz
Journal:  Exp Neurol       Date:  2010-12-11       Impact factor: 5.330

8.  Modulation of mu rhythm desynchronization during motor imagery by transcranial direct current stimulation.

Authors:  Jun Matsumoto; Toshiyuki Fujiwara; Osamu Takahashi; Meigen Liu; Akio Kimura; Junichi Ushiba
Journal:  J Neuroeng Rehabil       Date:  2010-06-11       Impact factor: 4.262

9.  Population-based stroke survey in Mumbai, India: incidence and 28-day case fatality.

Authors:  P M Dalal; S Malik; M Bhattacharjee; N D Trivedi; J Vairale; P Bhat; S Deshmukh; K Khandelwal; V D Mathur
Journal:  Neuroepidemiology       Date:  2008-10-20       Impact factor: 3.282

Review 10.  Quantitative EEG for the detection of brain ischemia.

Authors:  Brandon Foreman; Jan Claassen
Journal:  Crit Care       Date:  2012-12-12       Impact factor: 9.097

View more
  8 in total

1.  Design of NIRS Probe Based on Computational Model to Find Out the Optimal Location for Non-Invasive Brain Stimulation.

Authors:  Gaurav Sharma; Shubhajit Roy Chowdhury
Journal:  J Med Syst       Date:  2018-10-29       Impact factor: 4.460

2.  Statistical Analysis to Find out the Optimal Locations for Non Invasive Brain Stimulation.

Authors:  Gaurav Sharma; Shubhajit Roy Chowdhury
Journal:  J Med Syst       Date:  2020-03-12       Impact factor: 4.460

Review 3.  Simultaneous functional near-infrared spectroscopy and electroencephalography for monitoring of human brain activity and oxygenation: a review.

Authors:  Antonio M Chiarelli; Filippo Zappasodi; Francesco Di Pompeo; Arcangelo Merla
Journal:  Neurophotonics       Date:  2017-08-22       Impact factor: 3.593

Review 4.  Hybrid Brain-Computer Interface Techniques for Improved Classification Accuracy and Increased Number of Commands: A Review.

Authors:  Keum-Shik Hong; Muhammad Jawad Khan
Journal:  Front Neurorobot       Date:  2017-07-24       Impact factor: 2.650

Review 5.  Systemic Review on Transcranial Electrical Stimulation Parameters and EEG/fNIRS Features for Brain Diseases.

Authors:  Dalin Yang; Yong-Il Shin; Keum-Shik Hong
Journal:  Front Neurosci       Date:  2021-03-26       Impact factor: 4.677

6.  Computational Pipeline for NIRS-EEG Joint Imaging of tDCS-Evoked Cerebral Responses-An Application in Ischemic Stroke.

Authors:  Debarpan Guhathakurta; Anirban Dutta
Journal:  Front Neurosci       Date:  2016-06-20       Impact factor: 4.677

7.  Concurrent measurement of cerebral hemodynamics and electroencephalography during transcranial direct current stimulation.

Authors:  Martina Giovannella; David Ibañez; Clara Gregori-Pla; Michal Kacprzak; Guillem Mitjà; Giulio Ruffini; Turgut Durduran
Journal:  Neurophotonics       Date:  2018-01-25       Impact factor: 3.593

8.  An EEG Experimental Study Evaluating the Performance of Texas Instruments ADS1299.

Authors:  Usman Rashid; Imran Khan Niazi; Nada Signal; Denise Taylor
Journal:  Sensors (Basel)       Date:  2018-11-01       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.