Literature DB >> 27168134

The incidence of and factors affecting iliosacral screw loosening in pelvic ring injury.

Joon-Woo Kim1, Chang-Wug Oh2, Jong-Keon Oh3, Hee-Soo Kyung1, Kyeong-Hyeon Park1, Seong-Dae Yoon1, Sung-Hyuk Yoon1.   

Abstract

INTRODUCTION: Iliosacral screw fixation has been commonly used for stabilization of the posterior ring in unstable pelvic fractures. However, loosening of the screw may develop with or without redisplacement of the fracture. This study was undertaken to evaluate the incidence of iliosacral screw loosening and to identify its predictive factors.
MATERIALS AND METHODS: In total, 110 patients whose posterior pelvic ring was stabilized with iliosacral screws were enrolled. These included 9 cases of anteroposterior compression, 64 cases of lateral compression, and 37 cases of vertical shear (VS) injuries. Among those with posterior pelvic ring injuries, 95 had sacral fractures (zone I: 52, zone II: 43) and 15 had sacroiliac joint dislocations. The screws were fixed to the anterior one-third region of the first sacral (S1) body in 46 cases, and to the middle one-third region in the remaining 64 cases. If loosening of the iliosacral screw influenced the pelvic ring stability, it was considered a failure. The relationship between iliosacral screw loosening and the possible influencing factors were analyzed.
RESULTS: Nineteen patients (17.3 %) were found to have loosening of the iliosacral screw at a mean 25.3 days postoperatively. Of these, 13 patients (11.8 %) had failure of the screws. The incidence of iliosacral screw loosening was significantly higher in those with VS injury (29.7 %, p = 0.014), in those with screw fixed to the middle one-third region of the S1 body (23.4 %, p = 0.044), and in those with VS injury combined with zone II sacral fracture (43.5 %, p = 0.019). With respect to failure of the iliosacral screw, patients with VS injury also had a higher incidence of failure (21.6 %, p = 0.036).
CONCLUSIONS: Our findings demonstrate that cases with VS injuries are prone to screw loosening, especially when combined with zone II sacral fracture. Accordingly, alternative fixation methods should be considered in such cases.

Entities:  

Keywords:  Failure; Iliosacral screw; Loosening; Pelvic ring injury

Mesh:

Year:  2016        PMID: 27168134     DOI: 10.1007/s00402-016-2471-3

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  15 in total

1.  Application of the Guiding Template Designed by Three-dimensional Printing Data for the Insertion of Sacroiliac Screws: a New Clinical Technique.

Authors:  Yi Liu; Wu Zhou; Tian Xia; Jing Liu; Bo-Bin Mi; Liang-Cong Hu; Zeng-Wu Shao; Guo-Hui Liu
Journal:  Curr Med Sci       Date:  2018-12-07

2.  Fully threaded sacroiliac lag screws have higher load to failure when compared to partially threaded screws: A biomechanical study.

Authors:  Huai Ming Phen; Brent Wise; Daniel Thompson; Jason Nascone; Adam Boissonneault; Michael Maceroli
Journal:  J Clin Orthop Trauma       Date:  2020-10-19

3.  Minimally invasive lumbopelvic stabilization of sacral fragility fractures in immobilized geriatric patients: feasibility and early return to mobility.

Authors:  Peter Obid; Andreas Conta; Philipp Drees; Peer Joechel; Thomas Niemeyer; Norbert Schütz
Journal:  Arch Orthop Trauma Surg       Date:  2020-09-26       Impact factor: 3.067

4.  Computational simulation study on ilio-sacral screw fixations for pelvic ring injuries and implications in Asian sacrum.

Authors:  Chang-Soo Chon; Jin-Hoon Jeong; Bokku Kang; Han Sung Kim; Gu-Hee Jung
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-13

5.  Reduction and temporary stabilization of Tile C pelvic ring injuries using a posteriorly based external fixation system.

Authors:  Murphy P Martin; David Rojas; Cyril Mauffrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-12-05

6.  A novel computer navigation method for accurate percutaneous sacroiliac screw implantation: A technical note and literature review.

Authors:  Tong Yu; Shuang Zheng; Xiwen Zhang; Dongsheng Wang; Mingyang Kang; Rongpeng Dong; Yang Qu; Jianwu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.817

7.  Combined 3D Printed Template to Guide Iliosacral Screw Insertion for Sacral Fracture and Dislocation: A Retrospective Analysis.

Authors:  Chao Wu; Jia-Yan Deng; Tao Li; Lun Tan; De-Chao Yuan
Journal:  Orthop Surg       Date:  2020-02       Impact factor: 2.071

8.  Comparison of Biomechanical Performance of Five Different Treatment Approaches for Fixing Posterior Pelvic Ring Injury.

Authors:  Yongtao Lu; Yiqian He; Weiteng Li; Zhuoyue Yang; Ruifei Peng; Li Yu
Journal:  J Healthc Eng       Date:  2020-01-22       Impact factor: 2.682

9.  The three-dimensional bone mass distribution of the posterior pelvic ring and its key role in transsacral screw placement.

Authors:  Darius M Thiesen; Dimitris Ntalos; Josephine Berger-Groch; Andreas Petersik; Bernhard Hofstätter; Karl-Heinz Frosch; Maximilian J Hartel
Journal:  Sci Rep       Date:  2020-03-30       Impact factor: 4.379

10.  Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study.

Authors:  Moritz F Lodde; J Christoph Katthagen; Clemens O Schopper; Ivan Zderic; R Geoff Richards; Boyko Gueorguiev; Michael J Raschke; René Hartensuer
Journal:  Medicina (Kaunas)       Date:  2021-12-16       Impact factor: 2.430

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.