| Literature DB >> 27164987 |
Tomislav Bedeković1, Ivana Šimić2, Nina Krešić2, Ivana Lojkić2, Željko Mihaljević2, Ivica Sučec3, Ivana Lohman Janković3, Peter Hostnik4.
Abstract
BACKGROUND: The main goal of oral vaccination of foxes is eradication of rabies in the red fox population as rabies reservoirs. To evaluate the success of vaccination a serological testing is conducted as a part of monitoring program. Two different methods are used regarding rabies serology: virus neutralisation test and ELISA.Entities:
Keywords: BioPro ELISA; Evaluation; Muscle extract; Thoracic liquid
Mesh:
Substances:
Year: 2016 PMID: 27164987 PMCID: PMC4862130 DOI: 10.1186/s12917-016-0701-0
Source DB: PubMed Journal: BMC Vet Res ISSN: 1746-6148 Impact factor: 2.741
The sensitivity and specificity for the mFAVN test compared to FAVN test for different cut-offs
| Cut-off value | Sensitivity | Specificity | Correctly classified | Cumulative AUC | |
|---|---|---|---|---|---|
| 1. | 0.100 | 1.0000 | 1.0000 | ||
| 2. | 0.200 | 1.0000 | 1.0000 | ||
| 3. | 0.300 | 1.0000 | 0.9655 | 99.0000 | 0.9976 |
| 4. | 0.400 | 0.9706 | 0.8750 | 94.0000 | 0.9910 |
| 5. | 0.500 | 0.9440 | 0.8880 | 94.0000 | 0.9900 |
Results of testing for muscle extracts and thoracic liquids
| mFAVN test | ELISA | ELISA | ||||
|---|---|---|---|---|---|---|
| Not-heat-treated | Heat-treated | |||||
| Positive | Negative | Positive | Negative | Positive | Negative | |
| Thoracic liquid | 38 | 17 | 36 | 19 | 40 | 15 |
| Muscle extract | 15 | 77 | 5 | 87 | 23 | 69 |
| Total | 53 | 94 | 41 | 106 | 63 | 84 |
The cut –off for mFAVN test was set on 0.1 IU/ml
The cut –off for BioPro ELISA was set on 40 %
Results of sensitivity, specificity, diagnostic agreement and diagnostic validity for BioPro ELISA
| All samples | Muscle extracts | Thoracic liquids | ||||
|---|---|---|---|---|---|---|
| Not-heat treated treated | Heat | Not-heat treated treated | Heat | Not-heat treated treated | Heat | |
| Specificity | 92.98 % | 79.10 % | 100 % | 87.50 % | 89.47 % | 85.00 % |
| Sensitivity | 79.20 % | 96.36 % | 60 % | 83.33 % | 90.00 % | 97.43 % |
| Diagnostic agreement | 89.12 % | 87.76 % | 89.13 % | 84.78 % | 89.09 % | 92.73 % |
| Diagnostic validity | 89.16 % | 94.3 % | 70.30 % | 88.70 % | 95.98 % | 94.90 % |
| Confidential interval | 0.825–0.958 | 0.906–0.979 | 0.519–0.886 | 0.801–0.973 | 0.912–1.00 | 0.888–1.00 |
| Kappa | 0.7517 | 0.7449 | 0.4560 | 0.5410 | 0.7526 | 0.8240 |
Fig. 1a Correlation between titres of antibodies (IU/ml) in not-heat treated samples titrated by mFAVN test (cut off was set on 0.1 IU/ml) and percent of blocking obtained with BioPro ELISA (cut off was set on 40 %). b Correlation between titres of antibodies (IU/ml) in heat treated samples titrated by mFAVN test (cut off was set on 0.1 IU/ml) and percent of blocking obtained with BioPro ELISA (cut off was set on 40 %)
Fig. 2a Correlation between titres of antibodies (IU/ml) in not-heat treated thoracic liquids samples titrated by mFAVN test (cut off was set on 0.1 IU/ml) and percent of blocking obtained with BioPro ELISA (cut off was set on 40 %). b Correlation between titres of antibodies (IU/ml) in heat treated thoracic liquids samples titrated by mFAVN test (cut off was set on 0.1 IU/ml) and percent of blocking obtained with BioPro ELISA (cut off was set on 40 %)
Fig. 3a Correlation between titres of antibodies (IU/ml) in not-heat treated muscle extracts samples titrated by mFAVN test (cut off was set on 0.1 IU/ml) and percent of blocking obtained with BioPro ELISA (cut off was set on 40 %). b Correlation between titres of antibodies (IU/ml) in heat treated muscle extracts samples titrated by mFAVN (cut off was set on 0.1 IU/ml) and percent of blocking obtained with BioPro ELISA (cut off was set on 40 %)