Literature DB >> 27164479

Pencil beam proton radiography using a multilayer ionization chamber.

Paolo Farace1, Roberto Righetto, Arturs Meijers.   

Abstract

A pencil beam proton radiography (PR) method, using a commercial multilayer ionization chamber (MLIC) integrated with a treatment planning system (TPS) was developed. A Giraffe (IBA Dosimetry) MLIC (±0.5 mm accuracy) was used to obtain pencil beam PR by delivering spots uniformly positioned at a 5.0 mm distance in a 9  ×  9 square of spots. PRs of an electron-density (with tissue-equivalent inserts) phantom and a head phantom were acquired. The integral depth dose (IDD) curves of the delivered spots were computed by the TPS in a volume of water simulating the MLIC, and virtually added to the CT at the exit side of the phantoms. For each spot, measured and calculated IDD were overlapped in order to compute a map of range errors. On the head-phantom, the maximum dose from PR acquisition was estimated. Additionally, on the head phantom the impact on the range errors map was estimated in case of a 1 mm position misalignment. In the electron-density phantom, range errors were within 1 mm in the soft-tissue rods, but greater in the dense-rod. In the head-phantom the range errors were  -0.9  ±  2.7 mm on the whole map and within 1 mm in the brain area. On both phantoms greater errors were observed at inhomogeneity interfaces, due to sensitivity to small misalignment, and inaccurate TPS dose computation. The effect of the 1 mm misalignment was clearly visible on the range error map and produced an increased spread of range errors (-1.0  ±  3.8 mm on the whole map). The dose to the patient for such PR acquisitions would be acceptable as the maximum dose to the head phantom was  <2cGyE. By the described 2D method, allowing to discriminate misalignments, range verification can be performed in selected areas to implement an in vivo quality assurance program.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27164479     DOI: 10.1088/0031-9155/61/11/4078

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

Review 1.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

Review 2.  Status and innovations in pre-treatment CT imaging for proton therapy.

Authors:  Patrick Wohlfahrt; Christian Richter
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

Review 3.  Online daily adaptive proton therapy.

Authors:  Francesca Albertini; Michael Matter; Lena Nenoff; Ye Zhang; Antony Lomax
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

Review 4.  Latest developments in in-vivo imaging for proton therapy.

Authors:  Katia Parodi
Journal:  Br J Radiol       Date:  2019-12-12       Impact factor: 3.039

5.  Deriving the mean excitation energy map from dual-energy and proton computed tomography.

Authors:  Gloria Vilches-Freixas; Catherine Therese Quiñones; Jean Michel Létang; Simon Rit
Journal:  Phys Imaging Radiat Oncol       Date:  2018-04-26

6.  Inter-centre variability of CT-based stopping-power prediction in particle therapy: Survey-based evaluation.

Authors:  Vicki T Taasti; Christian Bäumer; Christina V Dahlgren; Amanda J Deisher; Malte Ellerbrock; Jeffrey Free; Joanna Gora; Anna Kozera; Antony J Lomax; Ludovic De Marzi; Silvia Molinelli; Boon-Keng Kevin Teo; Patrick Wohlfahrt; Jørgen B B Petersen; Ludvig P Muren; David C Hansen; Christian Richter
Journal:  Phys Imaging Radiat Oncol       Date:  2018-04-30

7.  Initial Validation of Proton Dose Calculations on SPR Images from DECT in Treatment Planning System.

Authors:  Sina Mossahebi; Pouya Sabouri; Haijian Chen; Michelle Mundis; Matthew O'Neil; Paul Maggi; Jerimy C Polf
Journal:  Int J Part Ther       Date:  2020-11-23

Review 8.  Management of Motion and Anatomical Variations in Charged Particle Therapy: Past, Present, and Into the Future.

Authors:  Julia M Pakela; Antje Knopf; Lei Dong; Antoni Rucinski; Wei Zou
Journal:  Front Oncol       Date:  2022-03-09       Impact factor: 6.244

9.  Dual-layer spectral CT for proton, helium, and carbon ion beam therapy planning of brain tumors.

Authors:  Friderike K Longarino; Thomas Tessonnier; Stewart Mein; Semi B Harrabi; Jürgen Debus; Wolfram Stiller; Andrea Mairani
Journal:  J Appl Clin Med Phys       Date:  2021-11-01       Impact factor: 2.102

10.  Clinical suitability of deep learning based synthetic CTs for adaptive proton therapy of lung cancer.

Authors:  Adrian Thummerer; Carmen Seller Oria; Paolo Zaffino; Arturs Meijers; Gabriel Guterres Marmitt; Robin Wijsman; Joao Seco; Johannes Albertus Langendijk; Antje-Christin Knopf; Maria Francesca Spadea; Stefan Both
Journal:  Med Phys       Date:  2021-11-16       Impact factor: 4.506