Literature DB >> 27163595

No More Waits and Delays: Streamlining Workflow to Decrease Patient Time of Stay for Image-guided Musculoskeletal Procedures.

Yvonne Y Cheung1, Eric M Goodman1, Tomiwa O Osunkoya1.   

Abstract

Long wait times limit our ability to provide the right care at the right time and are commonly products of inefficient workflow. In 2013, the demand for musculoskeletal (MSK) procedures increased beyond our department's ability to provide efficient and timely service. We initiated a quality improvement (QI) project to increase efficiency and decrease patient time of stay. Our project team included three MSK radiologists, one senior resident, one technologist, one administrative assistant/scheduler, and the lead technologist. We adopted and followed the Lean Six Sigma DMAIC (define, measure, analyze, improve, and control) approach. The team used tools such as voice of the customer (VOC), along with affinity and SIPOC (supplier, input, process, output, customer) diagrams, to understand the current process, identify our customers, and develop a project charter in the define stage. During the measure stage, the team collected data, created a detailed process map, and identified wastes with the value stream mapping technique. Within the analyze phase, a fishbone diagram helped the team to identify critical root causes for long wait times. Scatter plots revealed relationships among time variables. Team brainstorming sessions generated improvement ideas, and selected ideas were piloted via plan, do, study, act (PDSA) cycles. The control phase continued to enable the team to monitor progress using box plots and scheduled reviews. Our project successfully decreased patient time of stay. The highly structured and logical Lean Six Sigma approach was easy to follow and provided a clear course of action with positive results. (©)RSNA, 2016.

Entities:  

Mesh:

Year:  2016        PMID: 27163595     DOI: 10.1148/rg.2016150174

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  3 in total

1.  Optimization of MRI Turnaround Times Through the Use of Dockable Tables and Innovative Architectural Design Strategies.

Authors:  Michael P Recht; Kai Tobias Block; Hersh Chandarana; Jennifer Friedland; Thomas Mullholland; Donal Teahan; Roy Wiggins
Journal:  AJR Am J Roentgenol       Date:  2019-02-26       Impact factor: 3.959

Review 2.  The Role of Value Stream Mapping in Healthcare Services: A Scoping Review.

Authors:  Juan A Marin-Garcia; Pilar I Vidal-Carreras; Julio J Garcia-Sabater
Journal:  Int J Environ Res Public Health       Date:  2021-01-22       Impact factor: 3.390

Review 3.  AI musculoskeletal clinical applications: how can AI increase my day-to-day efficiency?

Authors:  YiRang Shin; Sungjun Kim; Young Han Lee
Journal:  Skeletal Radiol       Date:  2021-08-03       Impact factor: 2.199

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.