Literature DB >> 27154973

First Clinical Experience with Retrospective Flash Glucose Monitoring (FGM) Analysis in South Africa: Characterizing Glycemic Control with Ambulatory Glucose Profile.

Larry A Distiller1, Iain Cranston2, Roger Mazze2.   

Abstract

BACKGROUND: In 2014, an innovative blinded continuous glucose monitoring system was introduced with automated ambulatory glucose profile (AGP) reporting. The clinical use and interpretation of this new technology has not previously been described. Therefore we wanted to understand its use in characterizing key factors related to glycemic control: glucose exposure, variability, and stability, and risk of hypoglycemia in clinical practice.
METHODS: Clinicians representing affiliated diabetes centers throughout South Africa were trained and subsequently were given flash glucose monitoring readers and 2-week glucose sensors to use at their discretion. After patient use, sensor data were collected and uploaded for AGP reporting.
RESULTS: Complete data (sensor AGP with corresponding clinical information) were obtained for 50 patients with type 1 (70%) and type 2 diabetes (30%), irrespective of therapy. Aggregated analysis of AGP data comparing patients with type 1 versus type 2 diabetes, revealed that despite similar HbA1c values between both groups (8.4 ± 2 vs 8.6 ± 1.7%, respectively), those with type 2 diabetes had lower mean glucose levels (9.2 ± 3 vs 10.3 mmol/l [166 ± 54 vs 185 mg/dl]) and lower indices of glucose variability (3.0 ± 1.5 vs 5.0 ± 1.9 mmol/l [54 ± 27 vs 90 ± 34.2 mg/dl]). This highlights key areas for future focus.
CONCLUSIONS: Using AGP, the characteristics of glucose exposure, variability, stability, and hypoglycemia risk and occurrence were obtained within a short time and with minimal provider and patient input. In a survey at the time of the follow-up visit, clinicians indicated that aggregated AGP data analysis provided important new clinical information and insights.
© 2016 Diabetes Technology Society.

Entities:  

Keywords:  advanced glucose sensing technologies; ambulatory glucose profile; flash glucose monitoring

Mesh:

Substances:

Year:  2016        PMID: 27154973      PMCID: PMC5094324          DOI: 10.1177/1932296816648165

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  11 in total

Review 1.  An overview of continuous glucose monitoring and the ambulatory glucose profile.

Authors:  Roger Mazze; Bryan Akkerman; Jeanne Mettner
Journal:  Minn Med       Date:  2011-08

2.  Psychosocial factors associated with use of continuous glucose monitoring.

Authors:  M D Ritholz; A Atakov-Castillo; M Beste; E A Beverly; A Leighton; K Weinger; H Wolpert
Journal:  Diabet Med       Date:  2010-09       Impact factor: 4.359

3.  CGM Retrospective Data Analysis.

Authors:  Gary Scheiner
Journal:  Diabetes Technol Ther       Date:  2016-02       Impact factor: 6.118

4.  Glycemic variability: a hemoglobin A1c-independent risk factor for diabetic complications.

Authors:  Michael Brownlee; Irl B Hirsch
Journal:  JAMA       Date:  2006-04-12       Impact factor: 56.272

5.  Continuous glucose monitoring in the subcutaneous tissue over a 14-day sensor wear period.

Authors:  Udo Hoss; Erwin S Budiman; Hanqing Liu; Mark P Christiansen
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

6.  Relationship among A1C, hypoglycemia, and hyperglycemia in Japanese with type 2 diabetes--results from continuous glucose monitoring data.

Authors:  Aya Morimoto; Rimei Nishimura; Daisuke Tsujino; Kentaro Taki; Naoko Tajima; Kazunori Utsunomiya
Journal:  Diabetes Technol Ther       Date:  2011-04-02       Impact factor: 6.118

7.  Striving for the impossible dream: a community-based multi-practice collaborative model of diabetes management.

Authors:  L A Distiller; M A Brown; B I Joffe; B D Kramer
Journal:  Diabet Med       Date:  2010-02       Impact factor: 4.359

8.  Characterizing glucose exposure for individuals with normal glucose tolerance using continuous glucose monitoring and ambulatory glucose profile analysis.

Authors:  Roger S Mazze; Ellie Strock; David Wesley; Sarah Borgman; Blaine Morgan; Richard Bergenstal; Robert Cuddihy
Journal:  Diabetes Technol Ther       Date:  2008-06       Impact factor: 6.118

9.  Assessment of long-term glycemia in type I diabetes using multiple blood glucose values stored in a memory-containing reflectometer.

Authors:  H Shamoon; R Mazze; R Pasmantier; D Lucido; J A Murphy
Journal:  Am J Med       Date:  1986-06       Impact factor: 4.965

10.  Translating the A1C assay into estimated average glucose values.

Authors:  David M Nathan; Judith Kuenen; Rikke Borg; Hui Zheng; David Schoenfeld; Robert J Heine
Journal:  Diabetes Care       Date:  2008-06-07       Impact factor: 19.112

View more
  19 in total

1.  DTT: 19 Years and Counting ….

Authors:  Satish K Garg
Journal:  Diabetes Technol Ther       Date:  2017-02       Impact factor: 6.118

2.  Flash Glucose Monitoring: The Future Is Here.

Authors:  Satish K Garg; Halis Kaan Akturk
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

3.  Our First 825 T2DM Patients on 14-Day Factory-Calibrated Glucose Monitoring System: Clinical Utility and Challenges.

Authors:  Jothydev Kesavadev; Arun Shankar; Ashwin David Ashok; Sheeja Srinivas; Neethu Annie Ajai; Geethu Sanal; Gopika Krishnan; Lakshmy Ramachandran; Sunitha Jothydev
Journal:  J Diabetes Sci Technol       Date:  2017-07-05

4.  Effect of Different Nutritional Supplements on Glucose Response of Complete Meals in Two Crossover Studies.

Authors:  Nele Gheldof; Celia Francey; Andreas Rytz; Léonie Egli; Frederik Delodder; Lionel Bovetto; Nathalie Piccardi; Christian Darimont
Journal:  Nutrients       Date:  2022-06-28       Impact factor: 6.706

5.  Flash Continuous Glucose Monitoring: Implications for Use of Continuous Data in Daily Diabetes Management.

Authors:  Irl B Hirsch; Elizabeth Nardacci; Carol A Verderese
Journal:  Diabetes Spectr       Date:  2019-11

6.  The Potential Impact of the FreeStyle Libre Flash Glucose Monitoring System on Mental Well-Being and Treatment Satisfaction in Patients with Type 1 Diabetes: A Prospective Study.

Authors:  Ayman A Al Hayek; Mohamed A Al Dawish
Journal:  Diabetes Ther       Date:  2019-05-07       Impact factor: 2.945

Review 7.  Flash Glucose Monitoring: A Review of the Literature with a Special Focus on Type 1 Diabetes.

Authors:  Giulia Mancini; Maria Giulia Berioli; Elisa Santi; Francesco Rogari; Giada Toni; Giorgia Tascini; Roberta Crispoldi; Giulia Ceccarini; Susanna Esposito
Journal:  Nutrients       Date:  2018-07-29       Impact factor: 5.717

8.  Evaluation of FreeStyle Libre Flash Glucose Monitoring System on Glycemic Control, Health-Related Quality of Life, and Fear of Hypoglycemia in Patients with Type 1 Diabetes.

Authors:  Ayman A Al Hayek; Asirvatham A Robert; Mohamed A Al Dawish
Journal:  Clin Med Insights Endocrinol Diabetes       Date:  2017-12-10

9.  Practical guidance for treatment of patients with diabetes using flash glucose monitoring: a pilot study.

Authors:  Keiko Koide; Koichiro Azuma; Jun Nojima; Kenichiro Kodama; Yoshihito Atsumi
Journal:  Diabetol Metab Syndr       Date:  2018-08-07       Impact factor: 3.320

10.  Study protocol for a 9-month randomised controlled trial assessing the effects of almonds versus carbohydrate-rich snack foods on weight loss and weight maintenance.

Authors:  Sharayah Carter; Alison M Hill; Catherine Yandell; Jonathan D Buckley; Sze-Yen Tan; Geraint B Rogers; Jessie Childs; Mark Matheson; Kate Lamb; Susan Ward; Tasha R Stanton; Francois Fraysse; Andrew P Hills; Alison M Coates
Journal:  BMJ Open       Date:  2020-07-19       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.