| Literature DB >> 27150439 |
Yuan Ren1,2, Guo-Zhong Chen3, Zhen Liu1,2, Yan Cai4,5, Guang-Ming Lu6, Zhi-Yong Li7,8,9.
Abstract
BACKGROUND: Reconstruction of patient-specific biomechanical model of intracranial aneurysm has been based on different imaging modalities. However, different imaging techniques may influence the model geometry and the computational fluid dynamics (CFD) simulation. The aim of this study is to evaluate the differences of the morphological and hemodynamic parameters in the computational models reconstructed from computed tomography angiography (CTA), magnetic resonance angiography (MRA) and 3D rotational angiography (3DRA).Entities:
Keywords: Aneurysm; Angiography; CFD; CTA; DSA; MRA; Reproducibility
Mesh:
Year: 2016 PMID: 27150439 PMCID: PMC4858827 DOI: 10.1186/s12938-016-0163-4
Source DB: PubMed Journal: Biomed Eng Online ISSN: 1475-925X Impact factor: 2.819
Patient characteristics and aneurysm location
| No | Patient | Aneurysm | ||||
|---|---|---|---|---|---|---|
| Sex | Age | Smoking | Hypertension | Location | Rupture | |
| 1 | F | 60 | No | No | LICA | No |
| 2 | F | 59 | No | Yes | LICA_PCoA | Yes |
| 3 | M | 61 | Yes | No | LICA | No |
| 4 | F | 45 | No | Yes | RICA | Yes |
| 5 | F | 46 | No | Yes | AcoA | Yes |
| 6 | M | 49 | No | No | RICA_PCoA | No |
| 7 | F | 68 | No | No | LACA_A1 | No |
| 8 | M | 75 | No | No | LICA_PCoA | No |
| 9 | F | 64 | No | Yes | RPCoA | No |
| 10 | F | 37 | No | No | LICA_OphA | No |
Fig. 1Model reconstruction of patient-specific model. a A original image data, b a rough model by using the threshold segmentation and artificially adjusting, c the final model after surface smoothing, d showing different areas in the model. Arrows represent the aneurysm
Definition of the morphological parameters
| Morphological parameter | Abbreviation | Definition |
|---|---|---|
| Size | – | The maximum perpendicular height of the IA |
| Aspect ratio | AR | The ratio of the maximum perpendicular height to the average neck diameter |
| Neck area | NA | The minimum area of the neck |
| Parent vessel diameter | PVD | The diameter of the parent vessel |
| Size ratio | SR | The ratio of maximum aneurysm height to the PVD |
| Aneurysm angle | AA | The angle of inclination between the aneurysm and its neck plane |
| Surface distance | SD | The symmetrical Hausdroff distance between two models |
Fig. 2The illustration of the morphological parameters. a Definition of size and AR, b definition of AA and SR
Differences between models of morphologic parameters (mean ± SE)
| Differences | P value | |||
|---|---|---|---|---|
| CM and DM (%) | MM and DM (%) | CM and DM | MM and DM | |
| Size | 8.7 ± 1.39 | 6.6 ± 1.85 | 0.333 | 0.683 |
| AR | 8.3 ± 1.72 | 10.2 ± 1.66 | 0.953 | 0.203 |
| NA | 21.5 ± 5.5 | 15.4 ± 2.74 | 0.799 | 0.169 |
| PVD | 9.38 ± 1.08 | 12.07 ± 1.99 | 0.114 | 0.575 |
| SR | 9.49 ± 2.54 | 15.48 ± 3.09 | 0.959 | 0.760 |
| AA | 13.27 ± 2.46 | 10.13 ± 3.18 | 0.333 | 0.646 |
Fig. 3Differences distribution for morphologic parameters. a Difference between CM and MM, b difference between MM and DM
Fig. 4Surface distance distribution of a cerebral aneurysm located in ICA
Fig. 5Surface distance data (mean and standard deviation) of the patients
Fig. 6The distribution of AWSS, OSI and AWSSG in the three image based models (DM, CM and MM)
Fig. 7Differences distribution for hemodynamic parameters. a Difference between CM and DM, b difference between MM and DM
Differences between models of hemodynamic parameters (mean ± SE)
| Differences | P value | |||
|---|---|---|---|---|
| CM and DM (%) | MM and DM (%) | CM and DM | MM and DM | |
| AWSSA | 34 ± 5.13 | 40.6 ± 9.21 | 0.646 | 0.575 |
| AWSSP | 40.3 ± 6.21 | 40.4 ± 7.68 | 0.169 | 0.508 |
| LWSSA | 53.4 ± 8.91 | 32.9 ± 5.89 | 0.285 | 0.575 |
| MWSSA | 25.3 ± 6.3 | 34.8 ± 8.56 | 0.575 | 0.878 |
| 90WSSA | 42.6 ± 3.65 | 37.9 ± 10.67 | 0.445 | 0.959 |
| OSIA | 38.2 ± 8.6 | 29.9 ± 7.69 | 0.799 | 0.646 |
| MOSIA | 7.3 ± 1.79 | 13.8 ± 3.13 | 0.766 | 0.859 |
| HOSIA | 49.49 ± 8.76 | 63.35 ± 11.77 | 0.646 | 0.959 |
| AWSSGA | 24.8 ± 5.14 | 26.8 ± 5.73 | 0.093 | 0.386 |
Fig. 8Velocity-colored streamline at the peak systole of two aneurysms located on ACA-A1 (top row) and ACoA (bottom row). Models based on different imaging techniques were present from left to right (DM, CM and MM).The black arrow shows the flow direction
Agreement judgment of FP, IS and JS between different image based models
| Parameter | No. of categories | Agreement (k) | ||
|---|---|---|---|---|
| DM and CM | DM and MM | CM and MM | ||
| FP | 4 | 1 | 0.79 | 0.79 |
| IS | 4 | 0.78 | 1 | 0.78 |
| JS | 2 | 0.78 | 0.78 | 0.58 |