Literature DB >> 27147624

Serum indices: managing assay interference.

Christopher-John L Farrell1, Andrew C Carter2.   

Abstract

Clinical laboratories frequently encounter samples showing significant haemolysis, icterus or lipaemia. Technical advances, utilizing spectrophotometric measurements on automated chemistry analysers, allow rapid and accurate identification of such samples. However, accurate quantification of haemolysis, icterus and lipaemia interference is of limited value if laboratories do not set rational alert limits, based on sound interference testing experiments. Furthermore, in the context of increasing consolidation of laboratories and the formation of laboratory networks, there is an increasing requirement for harmonization of the handling of haemolysis, icterus and lipaemia-affected samples across different analytical platforms. Harmonization may be best achieved by considering both the analytical aspects of index measurement and the possible variations in the effects of haemolysis, icterus and lipaemia interferences on assays from different manufacturers. Initial verification studies, followed up with ongoing quality control testing, can help a laboratory ensure the accuracy of haemolysis, icterus and lipaemia index results, as well as assist in managing any biases in index results from analysers from different manufacturers. Similarities, and variations, in the effect of haemolysis, icterus and lipaemia interference in assays from different manufacturers can often be predicted from the mechanism of interference. Nevertheless, interference testing is required to confirm expected similarities or to quantify differences. It is important that laboratories are familiar with a number of interference testing protocols and the particular strengths and weaknesses of each. A rigorous approach to all aspects of haemolysis, icterus and lipaemia interference testing allows the analytical progress in index measurement to be translated into improved patient care.
© The Author(s) 2016.

Entities:  

Keywords:  Haemolysis; icterus; index; indices; interference; lipaemia

Mesh:

Year:  2016        PMID: 27147624     DOI: 10.1177/0004563216643557

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  22 in total

1.  Effects of marked hypertriglyceridemia and lipid clearance techniques on canine biochemistry testing.

Authors:  Carolina N Azevedo; Jonathan A Lidbury; Unity Jeffery
Journal:  J Vet Diagn Invest       Date:  2019-06-25       Impact factor: 1.279

2.  Hemolysis and IgA-antibodies against tissue transglutaminase: When are antibody test results no longer reliable?

Authors:  Johannes Wolf; Norman Haendel; Johannes Remmler; Carl Elias Kutzner; Thorsten Kaiser; Thomas Mothes
Journal:  J Clin Lab Anal       Date:  2017-11-23       Impact factor: 2.352

3.  Spectral Analysis Methods Based on Background Subtraction and Curvature Calculation Used in the Detection or Quantification of Hemolysis and Icterus in Blood-derived Clinical Samples.

Authors:  Toan Huynh; Michael J Lai; Yang L Liu; Linda Ly; Xinwei Gong; Kathryn R Rommel; Daniel L Young
Journal:  Cureus       Date:  2017-12-19

Review 4.  Haemolysis index for the screening of intravascular haemolysis: a novel diagnostic opportunity?

Authors:  Giuseppe Lippi; Emmanuel J Favaloro; Massimo Franchini
Journal:  Blood Transfus       Date:  2018-05-08       Impact factor: 3.443

5. 

Authors:  Imene Ben Jdidia; Kaouther Zribi; Meriam Boubaker; Amira Brahem; Mouna Sayadi; Marwa Tlijani; Zahra Saidani; Amani Cherif
Journal:  Can J Hosp Pharm       Date:  2021

6.  Removing Lipemia in Serum/Plasma Samples: A Multicenter Study.

Authors:  María José Castro-Castro; Beatriz Candás-Estébanez; Margarita Esteban-Salán; Pilar Calmarza; Teresa Arrobas-Velilla; Carlos Romero-Román; Miguel Pocoví-Mieras; José Ángel Aguilar-Doreste
Journal:  Ann Lab Med       Date:  2018-11       Impact factor: 3.464

7.  Internal quality assurance of HIL indices on Roche Cobas c702.

Authors:  Giuseppe Lippi; Janne Cadamuro; Elisa Danese; Matteo Gelati; Martina Montagnana; Alexander von Meyer; Gian Luca Salvagno; Ana-Maria Simundic
Journal:  PLoS One       Date:  2018-07-06       Impact factor: 3.240

8.  Verification of quantitative analytical methods in medical laboratories.

Authors:  Ghafar Muhammad T Abdel; Muhammad I El-Masry
Journal:  J Med Biochem       Date:  2021-06-05       Impact factor: 3.402

9.  Optimization of hemolysis, icterus and lipemia interference thresholds for 35 clinical chemistry assays.

Authors:  Clement K M Ho; Claire Chen; Johnson W S Setoh; Willie W T Yap; Robert C W Hawkins
Journal:  Pract Lab Med       Date:  2021-04-27

10.  Inhibition of Retrograde Transport Limits Polyomavirus Infection In Vivo.

Authors:  Saumya Maru; Ge Jin; Dhimant Desai; Shantu Amin; Matthew D Lauver; Aron E Lukacher
Journal:  mSphere       Date:  2017-11-15       Impact factor: 4.389

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.