Alexander M Grant1, Timothy W Deller2, Mohammad Mehdi Khalighi3, Sri Harsha Maramraju2, Gaspar Delso4, Craig S Levin5. 1. Department of Bioengineering, Stanford University, Stanford, California 94305-5128 and Department of Radiology, Stanford University, Stanford, California 94305-5128. 2. GE Healthcare, Waukesha, Wisconsin 53188-1678. 3. GE Healthcare, Applied Science Lab, Menlo Park, California 94025-3493. 4. GE Healthcare and University Hospital of Zurich, Zurich 8006, Switzerland. 5. Department of Bioengineering, Stanford University, Stanford, California 94305-5128; Department of Radiology, Stanford University, Stanford, California 94305-5128; Department of Electrical Engineering, Stanford University, Stanford, California 94305-5128; and Department of Physics, Stanford University, Stanford, California 94305-5128.
Abstract
PURPOSE: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. METHODS: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. RESULTS: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. CONCLUSIONS: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.
PURPOSE: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. METHODS: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. RESULTS: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. CONCLUSIONS: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.
Authors: Ida Sonni; Ryogo Minamimoto; Lucia Baratto; Sanjiv S Gambhir; Andreas M Loening; Shreyas S Vasanawala; Andrei Iagaru Journal: Mol Imaging Biol Date: 2020-04 Impact factor: 3.488
Authors: Georg Schramm; Martin Holler; Ahmadreza Rezaei; Kathleen Vunckx; Florian Knoll; Kristian Bredies; Fernando Boada; Johan Nuyts Journal: IEEE Trans Med Imaging Date: 2018-02 Impact factor: 10.048
Authors: Jaewon Yang; Florian Wiesinger; Sandeep Kaushik; Dattesh Shanbhag; Thomas A Hope; Peder E Z Larson; Youngho Seo Journal: J Nucl Med Date: 2017-05-04 Impact factor: 10.057
Authors: Ahmadreza Rezaei; Georg Schramm; Stefanie M A Willekens; Gaspar Delso; Koen Van Laere; Johan Nuyts Journal: J Nucl Med Date: 2019-04-12 Impact factor: 10.057
Authors: Mohammad Mehdi Khalighi; Timothy W Deller; Audrey Peiwen Fan; Praveen K Gulaka; Bin Shen; Prachi Singh; Jun-Hyung Park; Frederick T Chin; Greg Zaharchuk Journal: J Cereb Blood Flow Metab Date: 2017-02-03 Impact factor: 6.200
Authors: Zhaolin Chen; Sharna D Jamadar; Shenpeng Li; Francesco Sforazzini; Jakub Baran; Nicholas Ferris; Nadim Jon Shah; Gary F Egan Journal: Hum Brain Mapp Date: 2018-08-04 Impact factor: 5.038