Literature DB >> 27142098

Assessment of continuous acoustic respiratory rate monitoring as an addition to a pulse oximetry-based patient surveillance system.

Susan P McGrath1, Joshua Pyke2, Andreas H Taenzer3.   

Abstract

Technology advances make it possible to consider continuous acoustic respiratory rate monitoring as an integral component of physiologic surveillance systems. This study explores technical and logistical aspects of augmenting pulse oximetry-based patient surveillance systems with continuous respiratory rate monitoring and offers some insight into the impact on patient deterioration detection that may result. Acoustic respiratory rate sensors were introduced to a general care pulse oximetry-based surveillance system with respiratory rate alarms deactivated. Simulation was used after 4324 patient days to determine appropriate alarm thresholds for respiratory rate, which were then activated. Data were collected for an additional 4382 patient days. Physiologic parameters, alarm data, sensor utilization and patient/staff feedback were collected throughout the study and analyzed. No notable technical or workflow issues were observed. Sensor utilization was 57 %, with patient refusal leading reasons for nonuse (22.7 %). With respiratory rate alarm thresholds set to 6 and 40 breaths/min., the majority of nurse pager clinical notifications were triggered by low oxygen saturation values (43 %), followed by low respiratory rate values (21 %) and low pulse rate values (13 %). Mean respiratory rate collected was 16.6 ± 3.8 breaths/min. The vast majority (82 %) of low oxygen saturation states coincided with normal respiration rates of 12-20 breaths/min. Continuous respiratory rate monitoring can be successfully added to a pulse oximetry-based surveillance system without significant technical, logistical or workflow issues and is moderately well-tolerated by patients. Respiratory rate sensor alarms did not significantly impact overall system alarm burden. Respiratory rate and oxygen saturation distributions suggest adding continuous respiratory rate monitoring to a pulse oximetry-based surveillance system may not significantly improve patient deterioration detection.

Entities:  

Keywords:  Acoustic respiratory rate monitoring; Patient deterioration detection; Pulse oximetry; Surveillance monitoring

Mesh:

Year:  2016        PMID: 27142098     DOI: 10.1007/s10877-016-9884-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  9 in total

1.  Trends in inpatient hospital deaths: National Hospital Discharge Survey, 2000-2010.

Authors:  Margaret Jean Hall; Shaleah Levant; Carol J DeFrances
Journal:  NCHS Data Brief       Date:  2013-03

2.  Recognising clinical instability in hospital patients before cardiac arrest or unplanned admission to intensive care. A pilot study in a tertiary-care hospital.

Authors:  M D Buist; E Jarmolowski; P R Burton; S A Bernard; B P Waxman; J Anderson
Journal:  Med J Aust       Date:  1999-07-05       Impact factor: 7.738

3.  Hospital and patient characteristics associated with death after surgery. A study of adverse occurrence and failure to rescue.

Authors:  J H Silber; S V Williams; H Krakauer; J S Schwartz
Journal:  Med Care       Date:  1992-07       Impact factor: 2.983

Review 4.  A review of current and emerging approaches to address failure-to-rescue.

Authors:  Andreas H Taenzer; Joshua B Pyke; Susan P McGrath
Journal:  Anesthesiology       Date:  2011-08       Impact factor: 7.892

5.  Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia.

Authors:  O Mimoz; T Benard; A Gaucher; D Frasca; B Debaene
Journal:  Br J Anaesth       Date:  2012-02-08       Impact factor: 9.166

6.  Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study.

Authors:  Andreas H Taenzer; Joshua B Pyke; Susan P McGrath; George T Blike
Journal:  Anesthesiology       Date:  2010-02       Impact factor: 7.892

7.  Developing a continuous monitoring infrastructure for detection of inpatient deterioration.

Authors:  Joshua Pyke; Andreas H Taenzer; Christian E Renaud; Susan P McGrath
Journal:  Jt Comm J Qual Patient Saf       Date:  2012-09

8.  Continuous oximetry/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia.

Authors:  Frank J Overdyk; Rickey Carter; Ray R Maddox; Jarred Callura; Amy E Herrin; Craig Henriquez
Journal:  Anesth Analg       Date:  2007-08       Impact factor: 5.108

9.  Association between clinically abnormal observations and subsequent in-hospital mortality: a prospective study.

Authors:  Michael Buist; Stephen Bernard; Tuan V Nguyen; Gaye Moore; Jeremy Anderson
Journal:  Resuscitation       Date:  2004-08       Impact factor: 5.262

  9 in total
  7 in total

Review 1.  Journal of Clinical Monitoring and Computing 2017 end of year summary: respiration.

Authors:  D S Karbing; G Perchiazzi; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2018-02-26       Impact factor: 2.502

2.  Patterns in continuous pulse oximetry data prior to pulseless electrical activity arrest in the general care setting.

Authors:  Susan P McGrath; Irina M Perreard; Todd MacKenzie; George T Blike
Journal:  J Clin Monit Comput       Date:  2020-04-08       Impact factor: 2.502

3.  Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography.

Authors:  Sergio D Bergese; Michael L Mestek; Scott D Kelley; Robert McIntyre; Alberto A Uribe; Rakesh Sethi; James N Watson; Paul S Addison
Journal:  Anesth Analg       Date:  2017-04       Impact factor: 5.108

4.  Acoustic respiration rate and pulse oximetry-derived respiration rate: a clinical comparison study.

Authors:  Michal E Eisenberg; Dalia Givony; Raz Levin
Journal:  J Clin Monit Comput       Date:  2018-11-26       Impact factor: 2.502

5.  Novel wearable and contactless monitoring devices to identify deteriorating patients in the clinical setting: a systematic review protocol.

Authors:  Peter Y Chan; John McNeil; Tam Nguyen; Nicholas Ryan; Ingrid Hopper
Journal:  Syst Rev       Date:  2020-05-06

6.  Nursing attitudes towards continuous capnographic monitoring of floor patients.

Authors:  Catherine L Clark; Liza M Weavind; Sara E Nelson; Jennifer L Wilkie; Joel T Conway; Robert E Freundlich
Journal:  BMJ Open Qual       Date:  2018-09-15

7.  Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity.

Authors:  Susan P McGrath; Krystal M McGovern; Irina M Perreard; Viola Huang; Linzi B Moss; George T Blike
Journal:  J Patient Saf       Date:  2021-12-01       Impact factor: 2.243

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.