| Literature DB >> 27141268 |
Hossein Danafar1, Mehrdad Hamidi2.
Abstract
BACKGROUND: A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma.Entities:
Keywords: Clonidine hydrochloride; High performance liquid chromatography; Pharmacokinetics
Year: 2016 PMID: 27141268 PMCID: PMC4842247
Source DB: PubMed Journal: Avicenna J Med Biotechnol ISSN: 2008-2835
Figure 1.
Chemical structure of clonidine.
Figure 2.
The MRM (+) chromatograms of clonidine. A) Blank plasma, B) LOQ (concentration of clonidine=0.01 ng/ml). C) The MIM (+) chromatograms for plasma sample of a healthy volunteer; the concentration of clonidine was 1.12 ng/ml. D) Supplemented plasma (concentration of clonidine=4 ng/ml).
Within–run variations and accuracy of the LC-Mass method for quantitation of clonidine hydrochloride (n=3)
| 1 | 0.012 | 0.0109±0.001 | 9.57 | |
| 2 | 0.0099 | |||
| 3 | 0.011 | |||
| 1 | 1.03 | 1.05±0.072 | 6.86 | |
| 2 | 0.99 | |||
| 3 | 1.13 | |||
| 1 | 10.3 | 10.05±0.219 | 2.18 | |
| 2 | 9.96 | |||
| 3 | 9.89 |
Between–run variations and accuracy of the LC-Mass method for quantitation of clonidine hydrochloride (n=3)
| 1 | 0.012 | 0.011±0.0009 | 8.61 | |
| 2 | 0.099 | |||
| 3 | 0.014 | |||
| 1 | 0.99 | 1.03±0.078 | 7.58 | |
| 2 | 0.98 | |||
| 3 | 1.12 | |||
| 1 | 9.96 | 10.06±0.13 | 1.31 | |
| 2 | 10.21 | |||
| 3 | 10.01 |
Relative recovery of clonidine hydrochloride by the LC-Mass method (N=3)
| 1 | 99.25 | 96.80±2.5 | 2.62 | |
| 2 | 94.18 | |||
| 3 | 96.98 | |||
| 1 | 98.02 | 98.12±1.06 | 1.08 | |
| 2 | 97.11 | |||
| 3 | 99.23 | |||
| 1 | 97.32 | 96.76±2.22 | 2.29 | |
| 2 | 98.65 | |||
| 3 | 94.31 |
Repeatability of the test results for spiked plasma containing 1 ng/ml−1 clonidine hydrochloride
| 137235 | 137546±261.55 | 0.19 | 2.41 | 2.40±0.008 | 0.32 | |
| 137653 | -- | -- | 2.40 | -- | -- | |
| 137669 | -- | -- | 2.39 | -- | -- | |
| 137211 | -- | -- | 2.40 | -- | -- | |
| 137854 | -- | -- | 2.41 | -- | -- | |
| 137654 | -- | -- | 2.39 | -- | -- |
Intermediate precision of the test results for spiked plasma containing 1 ng/ml-clonidine hydrochloride
| 137698 | 137610±77.68 | 0.056 | 2.41 | 2.396±0.01 | 0.5 | |
| 137542 | -- | -- | 2.39 | -- | -- | |
| 137601 | -- | -- | 2.38 | -- | -- | |
| 137612 | -- | -- | 2.41 | -- | -- | |
| 137511 | -- | -- | 2.40 | -- | -- | |
| 137699 | -- | -- | 2.39 | -- | -- |
Data showing stability of clonidine hydrochloride in human plasma at different QC levels (n=5)
| 95.69 | 96.12 | 97.89 | |
| 97.87 | 97.89 | 96.54 | |
| 96.32 | 93.21 | 96.21 | |
| 95.48 | 96.87 | 93.89 |
Data are presented as the percentage of the remaining concentration to the initial starting concentration
Figure 3.
Comparative pharmacokinetic profile of clonidine hydro-chloride following oral administration of 0.2 mg test and reference products to healthy volunteers.
Pharmacokinetic parameters of clonidine hydrochloride after single oral dose of the test and reference product (Mean±SD)
| 6.16± 0.32 | 6.21±0.07 | |
| 30.12±0.86 | 30.13±0.73 | |
| 290.37±1.13 | 293.39±1.22 | |
| 350.17±1.98 | 352.96±1.67 | |
| 120.12±1.90 | 120.96±1.54 | |
| 22.1±1.01 | 23.6±0.56 |