Literature DB >> 27131926

Durability of the balloon-expandable covered versus bare-metal stents in the Covered versus Balloon Expandable Stent Trial (COBEST) for the treatment of aortoiliac occlusive disease.

Bibombe P Mwipatayi1, Surabhi Sharma2, Ali Daneshmand2, Shannon D Thomas3, Vikram Vijayan4, Nishath Altaf2, Marek Garbowski5, Mark Jackson6.   

Abstract

OBJECTIVE: The Covered vs Balloon Expandable Stent Trial (COBEST) is the first multicenter trial to investigate the patency of covered stents (CSs) and bare-metal stents (BMSs) in the treatment of aortoiliac arterial disease. The short-term results demonstrated that CSs were superior to BMSs in maintaining patency for TransAtlantic Inter-Society Consensus (TASC) C and D lesions at 18 months and were equivalent to BMSs for TASC B lesions. The current study was conducted to determine if the initial patency advantage of CSs over BMSs was sustained at the 5-year follow-up.
METHODS: A retrospective post hoc analysis of COBEST was performed. Originally, 125 patients with 168 iliac arteries were prospectively enrolled and randomly assigned to receive a CS or BMS. In this study, 77 of the 125 patients (61.6%; 119 limbs) were assessed at 60 months for the primary and secondary end points, with particular attention paid to the outcomes stratified according to TASC lesion severity. The primary end point was the rate of binary stenosis or freedom from stent occlusion of the treated area, as determined by ultrasound imaging or quantitative visual angiography.
RESULTS: The 5-year results of the COBEST showed that the CS had a significantly higher patency rate than the BMS at 18, 24, 48, and 60 months (95.1%, 82.1%, 79.9%, 74.7% for CS vs 73.9%, 70.9%, 63% and 62.5% for BMS; log-rank test, P = .01). On multivariate analysis, the type of stent used (hazard ratio [HR], 2.797; 95% confidence interval [CI], 1.471-5.318; P = .002) and the Rutherford classification (HR, 2.019; 95% CI, 1.278-3.191; P = .026) significantly affected the adjusted primary patency. On subgroup analysis, the CS showed significantly higher patency and a survival benefit compared with the BMS in TASC C and D lesions (HR, 8.639; 95% CI, 54.253-75.753; P = .003). Moreover, fewer patients received target limb revascularization in the CS group than in the BMS group (odds ratio, 2.32; 95% CI, 1.47-3.36; P = .02); however, there was no statistically significant difference in the rate of amputations between the groups.
CONCLUSIONS: The 5-year results of the COBEST demonstrated that the CS has an enduring patency advantage over the BMS in both the short and long terms. Furthermore, the CS showed acceptable patency rates for the treatment of more severe TASC C and D lesions, and patients who received a CS required fewer revascularization procedures. However, the choice of stent did not affect the rate of major limb amputations.
Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27131926     DOI: 10.1016/j.jvs.2016.02.064

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  21 in total

Review 1.  Radial Access for Lower Extremity Peripheral Arterial Interventions: Do We Have the Tools?

Authors:  Raghuram Posham; Lindsay B Young; Robert A Lookstein; Constantino Pena; Rahul S Patel; Aaron M Fischman
Journal:  Semin Intervent Radiol       Date:  2019-02-05       Impact factor: 1.513

2.  SCAI guidelines on device selection in Aorto-Iliac arterial interventions.

Authors:  Dmitriy N Feldman; Ehrin J Armstrong; Herbert D Aronow; Subhash Banerjee; Larry J Díaz-Sandoval; Michael R Jaff; Sasanka Jayasuriya; Safi U Khan; Andrew J Klein; Sahil A Parikh; Kenneth Rosenfield; Mehdi H Shishehbor; Rajesh V Swaminathan; Christopher J White
Journal:  Catheter Cardiovasc Interv       Date:  2020-05-14       Impact factor: 2.692

3.  Angioplasty versus stenting for iliac artery lesions.

Authors:  Hidde Jongsma; Joost Bekken; Ninos Ayez; Cornelis J Hoogewerf; Vincent Van Weel; Bram Fioole
Journal:  Cochrane Database Syst Rev       Date:  2020-12-01

4.  A Computational Framework Examining the Mechanical Behaviour of Bare and Polymer-Covered Self-Expanding Laser-Cut Stents.

Authors:  Ciara G McKenna; Ted J Vaughan
Journal:  Cardiovasc Eng Technol       Date:  2021-11-30       Impact factor: 2.305

5.  Combining transradial access and sheathless femoral access for complex iliac artery chronic total occlusions.

Authors:  Naoki Hayakawa; Satoshi Kodera; Keisuke Takanashi; Shinya Ichihara; Satoshi Hirano; Masataka Arakawa; Yasunori Inoguchi; Junji Kanda
Journal:  CVIR Endovasc       Date:  2022-10-24

Review 6.  [Recommended interventions for the treatment of peripheral artery disease : Keep the patients moving].

Authors:  H Krankenberg
Journal:  Internist (Berl)       Date:  2019-12       Impact factor: 0.743

7.  Endovascular and Hybrid Revascularization for Complicated Aorto-Iliac Occlusive Disease: Short-Term Results in Single Institute Experience.

Authors:  Tai-Wei Chen; Chun-Yang Huang; Po-Lin Chen; Chiu-Yang Lee; Chun-Che Shih; I-Ming Chen
Journal:  Acta Cardiol Sin       Date:  2018-07       Impact factor: 2.672

Review 8.  [Aortic bifurcation reconstruction : Endovascular repair and alternatives].

Authors:  K Schürmann
Journal:  Radiologe       Date:  2018-09       Impact factor: 0.635

9.  Long-term results of endovascular reconstruction for aortoiliac occlusive disease.

Authors:  Min Yang; Bihui Zhang; Guochen Niu; Ziguang Yan; Xiaoqiang Tong; Yinghua Zou
Journal:  Quant Imaging Med Surg       Date:  2021-04

10.  Midterm outcomes of endovascular treatment with bare metal stents for Leriche syndrome patients.

Authors:  Bihui Zhang; Guochen Niu; Ziguang Yan; Yinghua Zou; Xiaoqiang Tong; Min Yang
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-01-01
View more