Literature DB >> 27124823

A Comparison of Three C-Arm Draping Techniques to Minimize Contamination of the Surgical Field.

Grigory E Gershkovich1, Nathan C Tiedeken, David Hampton, Ross Budacki, Solomon P Samuel, Minn Saing.   

Abstract

The use of intraoperative fluoroscopy has become a routine and useful adjunct within orthopaedic surgery. However, the fluoroscopy machine may become an additional source of contamination in the operating room, particularly when maneuvering from the anterior-posterior position to the lateral position. Consequently, draping techniques were developed to maintain sterility of the operative field and surgeon. Despite a variety of methods, no studies exist to compare the sterility of these techniques specifically when the fluoroscopy machine is in the lateral imaging position. We evaluated the sterility of 3 c-arm draping techniques in a simulated operative environment. The 3 techniques consisted of a traditional 3-quarter sterile sheet attached to the side of the operative table, a modified clip-drape method, and a commercially available sterile pouch. Our study demonstrated that the traditional method poses a high risk for sterile field contamination, whereas the modified clip-drape method and commercially available sterile pouch kept floor contamination furthest from the surgical field. With the current data, we urge surgeons to use modified techniques rather than the traditional draping method.

Mesh:

Year:  2016        PMID: 27124823     DOI: 10.1097/BOT.0000000000000619

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  5 in total

1.  Sterility of Miniature C-arm Fluoroscopy in Hand and Upper Extremity Surgery.

Authors:  James P Hovis; Stephanie N Moore-Lotridge; Ashton Mansour; Breanne H Y Gibson; Douglas R Weikert; Mihir J Desai; Sandra S Gebhart; Jonathan G Schoenecker; Donald H Lee
Journal:  J Hand Microsurg       Date:  2020-07-26

2.  Examination of fluoroscopy monitor as a source of indirect bacterial contamination in orthopaedic surgery.

Authors:  Joseph M Radley; Daniel S Gloekler; Mark A Krahe; Jeffrey A Nechleba
Journal:  J Infect Prev       Date:  2020-05-04

3.  Time to entry point and distal locking of intramedullary nails: a methodological phantom study comparing biplanar and uniplanar surgical imaging.

Authors:  Peter Ström; Nils P Hailer; Olof Wolf
Journal:  BMC Musculoskelet Disord       Date:  2022-02-24       Impact factor: 2.362

4.  A new mini-navigation tool allows accurate component placement during anterior total hip arthroplasty.

Authors:  Javad Parvizi; Jessica R Benson; Jeffrey M Muir
Journal:  Med Devices (Auckl)       Date:  2018-03-22

5.  Does the use of intraoperative fluoroscopy improve postoperative radiographic component positioning and implant size in total hip arthroplasty utilizing a direct anterior approach?

Authors:  David C Holst; Daniel L Levy; Marc R Angerame; Charlie C Yang
Journal:  Arthroplast Today       Date:  2019-12-28
  5 in total