Literature DB >> 2712294

Multiple fluorescence labeling with europium chelators. Application to time-resolved fluoroimmunoassays.

E P Diamandis, R C Morton, E Reichstein, M J Khosravi.   

Abstract

Multiple fluorescence labeling with conventional probes like fluorescein, to improve the detection limit of labeled reactants, is not usually successful because of fluorescence quenching. In contrast, we found that the europium chelator 4,7-bis(chlorosulfophenyl)-1,10-phenanthroline-2,9-dicarboxylic acid (BCPDA) can be incorporated into proteins at very high molar ratios. Working with thyroglobulin as a model protein, we found that when 160 BCPDA molecules are incorporated into one thyroglobulin molecule, the fluorescence emitted by the labeled protein in the presence of excess Eu3+, is equivalent to that emitted by approximately 900 molecules of unconjugated BCPDA:Eu3+ complexes. We took advantage of the lack of any quenching effects and of the enhancement observed with the multiply labeled protein, to develop a universal reagent system consisting of (a) streptavidin covalently coupled to BCPDA labeled thyroglobulin and (b) excess Eu3+. With this approach, streptavidin is heavily labeled through thyroglobulin and retains its full biotin binding activity. We used the reagent to develop a highly sensitive time-resolved heterogeneous immunofluorometric assay of alpha-fetoprotein (AFP) in serum, using monoclonal antibodies. One antibody is immobilized in white microtitration wells (solid-phase) and the other is biotinylated. We demonstrate that this assay, using the newly developed reagent, is 25-fold more sensitive than the one using directly BCPDA labeled antibody and 5-fold more sensitive than an assay that uses BCPDA-labeled streptavidin. The detection limit of the assay with the new reagent was down to 60 amol of AFP per well. We conclude that multiple fluorescence labeling with europium chelators is an effective method of extending the sensitivity of currently used fluorescence immunoassay procedures.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2712294     DOI: 10.1021/ac00176a011

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Time-resolved fluoroimmunoassay.

Authors:  P Degan; A Podestà; G Montagnoli
Journal:  Mol Biotechnol       Date:  1999-12-15       Impact factor: 2.695

2.  Quantification of nucleic acids on nitrocellulose membranes with time-resolved fluorometry.

Authors:  T K Christopoulos; E P Diamandis; G Wilson
Journal:  Nucleic Acids Res       Date:  1991-11-11       Impact factor: 16.971

3.  Detection of immunoglobulins G and M to rubella virus by time-resolved immunofluorometry.

Authors:  P Shankaran; E Reichstein; M J Khosravi; E P Diamandis
Journal:  J Clin Microbiol       Date:  1990-03       Impact factor: 5.948

Review 4.  Lanthanide-based time-resolved luminescence immunoassays.

Authors:  A K Hagan; T Zuchner
Journal:  Anal Bioanal Chem       Date:  2011-05-11       Impact factor: 4.142

  4 in total