Literature DB >> 27113877

Accuracy of toric intraocular lens axis alignment using a 3-dimensional computer-guided visualization system.

Ildamaris Montes de Oca1, Eric J Kim1, Li Wang1, Mitchell P Weikert1, Sumitra S Khandelwal1, Zaina Al-Mohtaseb1, Douglas D Koch2.   

Abstract

PURPOSE: To evaluate the accuracy of toric intraocular lens (IOL) alignment in femtosecond laser-assisted cataract surgery using the Truevision 3-dimensional (3-D) computer-guided visualization system compared with a manual marking method.
SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA.
DESIGN: Retrospective comparative case series.
METHODS: Preoperatively, all patients had corneal topography measurements with a color light-emitting diode topographer. The 3-D system used the anterior keratometry values to create an optimized plan for the toric IOL alignment. Intrastromal marks were created by the femtosecond laser at the intended toric meridian, guided by manual ink marks placed at the 3 o'clock and 9 o'clock limbus with the patient sitting upright. Intraoperatively, the 3-D system was used to align the IOL and measure the angular position of the femtosecond marks relative to the IOL meridian. Three weeks postoperatively, the manifest refraction, corrected distance visual acuity, and toric IOL alignment were recorded.
RESULTS: The mean 3-D imaging error was -0.58 degrees ± 3.90 (SD) (range -9 to 5 degrees), and the mean manual ink error was -0.27 ± 3.65 degrees (range -8 to 5 degrees); neither was statistically significantly different from zero (P = .28 and P = .76, respectively). The mean absolute errors were 2.96 ± 2.54 degrees and 2.88 ± 2.18 degrees, respectively.
CONCLUSION: The 3-D computer-guided system and manual marking combined with femtosecond laser marks were similar in accuracy for toric alignment. FINANCIAL DISCLOSURES: Dr. Wang received research support from Ziemer USA, Inc. Dr. Weikert is a consultant to Ziemer USA, Inc. Dr. Koch is a consultant to Alcon Laboratories, Inc., and Abbott Medical Optics, Inc., and received research support from Ziemer USA, Inc., i-Optics Corp, and Truevision Systems. None of the other authors has a financial or proprietary interest in any material or method mentioned.
Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27113877     DOI: 10.1016/j.jcrs.2015.12.052

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  THE INTEGRATIVE SURGICAL THEATER: Combining Intraoperative Optical Coherence Tomography and 3D Digital Visualization for Vitreoretinal Surgery in the DISCOVER Study.

Authors:  Justis P Ehlers; Atsuro Uchida; Sunil K Srivastava
Journal:  Retina       Date:  2018-09       Impact factor: 4.256

Review 2.  Optimizing outcomes with toric intraocular lenses.

Authors:  Manpreet Kaur; Farin Shaikh; Ruchita Falera; Jeewan S Titiyal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

3.  Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

Authors:  Jeewan S Titiyal; Manpreet Kaur; Cijin P Jose; Ruchita Falera; Ashutosh Kinkar; Lalit Ms Bageshwar
Journal:  Clin Ophthalmol       Date:  2018-04-24

4.  Results of Callisto Eye System in Toric Intraocular Lens Alignment.

Authors:  Bulent Kose; Sinan Albayrak
Journal:  Beyoglu Eye J       Date:  2020-02-14

5.  Comparison of Toric Intraocular Lens Alignment Using Image-Guided System and Manual Marking Technique.

Authors:  Bulent Kose; Hakika Erdogan
Journal:  Beyoglu Eye J       Date:  2020-07-29

Review 6.  Toric intraocular lenses: Expanding indications and preoperative and surgical considerations to improve outcomes.

Authors:  Vivek Mahendrapratap Singh; Muralidhar Ramappa; Somasheila I Murthy; Audrey Talley Rostov
Journal:  Indian J Ophthalmol       Date:  2022-01       Impact factor: 1.848

7.  Digital versus slit-beam marking for toric intraocular lenses in cataract surgery.

Authors:  Ning Ding; Xiaozhen Wang; Xudong Song
Journal:  BMC Ophthalmol       Date:  2022-07-27       Impact factor: 2.086

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.