M I Garvey1, R Ashford2, C W Bradley2, C R Bradley3, T A Martin2, J Walker4, P Jumaa2. 1. University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital Birmingham, Edgbaston, Birmingham, UK. Electronic address: mark.garvey@uhb.nhs.uk. 2. University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital Birmingham, Edgbaston, Birmingham, UK. 3. Hospital Infection Research Laboratory, University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital Birmingham, Birmingham, UK. 4. Public Health England, National Infection Service, Biosafety, Air and Water Microbiology Group, Salisbury, UK.
Abstract
BACKGROUND: Non-tuberculosis mycobacteria such as Mycobacterium chimaera are found widely in hospital water systems. Invasive M. chimaera infections have recently been attributed to heater-cooler units (HCUs) of cardiopulmonary bypass equipment. AIM: To assess the extent of microbiological contamination within the HCUs and to inform decontamination strategies for reducing the microbial load. METHODS: Water samples taken from HCUs used at University Hospitals Birmingham for cardiopulmonary bypass surgery were sampled to determine the number of micro-organisms by membrane filtration. Various decontamination processes were used throughout the study, all based on the manufacturer's guidance. FINDINGS: Total viable counts >300cfu per 100mL containing a wide variety of micro-organisms were obtained from water inside the HCUs. Working with the manufacturers, we significantly reduced the microbial load of the water within the HCUs by removing the internal tubing soiled with biofilm followed by a weekly decontamination regimen with peracetic acid. CONCLUSION: A decontamination cycle including an initial replacement of internal tubing with weekly microbiological water samples is required to maintain the water quality within HCUs at an acceptable level.
BACKGROUND:Non-tuberculosis mycobacteria such as Mycobacterium chimaera are found widely in hospital water systems. Invasive M. chimaera infections have recently been attributed to heater-cooler units (HCUs) of cardiopulmonary bypass equipment. AIM: To assess the extent of microbiological contamination within the HCUs and to inform decontamination strategies for reducing the microbial load. METHODS:Water samples taken from HCUs used at University Hospitals Birmingham for cardiopulmonary bypass surgery were sampled to determine the number of micro-organisms by membrane filtration. Various decontamination processes were used throughout the study, all based on the manufacturer's guidance. FINDINGS: Total viable counts >300cfu per 100mL containing a wide variety of micro-organisms were obtained from water inside the HCUs. Working with the manufacturers, we significantly reduced the microbial load of the water within the HCUs by removing the internal tubing soiled with biofilm followed by a weekly decontamination regimen with peracetic acid. CONCLUSION: A decontamination cycle including an initial replacement of internal tubing with weekly microbiological water samples is required to maintain the water quality within HCUs at an acceptable level.
Authors: T Ogunremi; G Taylor; L Johnston; K Amaratunga; M Muller; A Coady; K Defalco; K Dunn; J Johnstone; S Smith; J Embree; B Henry; J Stafford Journal: Can Commun Dis Rep Date: 2017-05-04
Authors: Meera Chand; Theresa Lamagni; Katharina Kranzer; Jessica Hedge; Ginny Moore; Simon Parks; Samuel Collins; Carlos Del Ojo Elias; Nada Ahmed; Tim Brown; E Grace Smith; Peter Hoffman; Peter Kirwan; Brendan Mason; Alison Smith-Palmer; Philip Veal; Maeve K Lalor; Allan Bennett; James Walker; Alicia Yeap; Antonio Isidro Carrion Martin; Gayle Dolan; Sonia Bhatt; Andrew Skingsley; André Charlett; David Pearce; Katherine Russell; Simon Kendall; Andrew A Klein; Stephen Robins; Silke Schelenz; William Newsholme; Stephanie Thomas; Tim Collyns; Eleri Davies; Jim McMenamin; Lorraine Doherty; Tim E A Peto; Derrick Crook; Maria Zambon; Nick Phin Journal: Clin Infect Dis Date: 2016-12-07 Impact factor: 20.999
Authors: Peter W Schreiber; Stefan P Kuster; Barbara Hasse; Cornelia Bayard; Christian Rüegg; Philipp Kohler; Peter M Keller; Guido V Bloemberg; Francesco Maisano; Dominique Bettex; Maximilian Halbe; Rami Sommerstein; Hugo Sax Journal: Emerg Infect Dis Date: 2016-10 Impact factor: 6.883
Authors: Franziska C Trudzinski; Uwe Schlotthauer; Annegret Kamp; Kai Hennemann; Ralf M Muellenbach; Udo Reischl; Barbara Gärtner; Heinrike Wilkens; Robert Bals; Mathias Herrmann; Philipp M Lepper; Sören L Becker Journal: Euro Surveill Date: 2016-11-17
Authors: Archana D Siddam; Shari J Zaslow; Yi Wang; K Scott Phillips; Matthew D Silverman; Patrick M Regan; Jayaleka J Amarasinghe Journal: Front Microbiol Date: 2021-01-11 Impact factor: 5.640