Literature DB >> 27109010

Characterization of Transition to Turbulence for Blood in a Straight Pipe Under Steady Flow Conditions.

Dipankar Biswas, David M Casey, Douglas C Crowder, David A Steinman, Yang H Yun, Francis Loth.   

Abstract

Blood is a complex fluid that, among other things, has been established to behave as a shear thinning, non-Newtonian fluid when exposed to low shear rates (SR). Many hemodynamic investigations use a Newtonian fluid to represent blood when the flow field of study has relatively high SR (>200 s-1). Shear thinning fluids have been shown to exhibit differences in transition to turbulence (TT) compared to that of Newtonian fluids. Incorrect prediction of the transition point in a simulation could result in erroneous hemodynamic force predictions. The goal of the present study was to compare velocity profiles near TT of whole blood and Newtonian blood analogs in a straight rigid pipe with a diameter 6.35 mm under steady flow conditions. Rheology was measured for six samples of whole porcine blood and three samples of a Newtonian fluid, and the results show blood acts as a shear thinning non-Newtonian fluid. Measurements also revealed that blood viscosity at SR = 200 s-1 is significantly larger than at SR = 1000 s-1 (13.8%, p < 0.001). Doppler ultrasound (DUS) was used to measure velocity profiles for blood and Newtonian samples at different flow rates to produce Reynolds numbers (Re) ranging from 1000 to 3300 (based on viscosity at SR = 1000 s-1). Two mathematically defined methods, based on the velocity profile shape change and turbulent kinetic energy (TKE), were used to detect TT. Results show similar parabolic velocity profiles for both blood and the Newtonian fluid for Re < 2200. However, differences were observed between blood and Newtonian fluid velocity profiles for larger Re. The Newtonian fluid had blunt-like velocity profiles starting at Re = 2403 ± 8 which indicated transition. In contrast, blood did not show this velocity profile change until Re = 2871 ± 104. The Newtonian fluid had large velocity fluctuations (root mean square (RMS) > 20%) with a maximum TKE near the pipe center at Re = 2316 ± 34 which indicated transition. In contrast, blood results showed the maximum TKE at Re = 2806 ± 109. Overall, the critical Re was delayed by ∼20% (p < 0.001) for blood compared to the Newtonian fluid. Thus, a Newtonian assumption for blood at flow conditions near transition could lead to large errors in velocity prediction for steady flow in a straight pipe. However, these results are specific to this pipe diameter and not generalizable since SR is highly dependent on pipe diameter. Further research is necessary to understand this relation in different pipe sizes, more complex geometries, and under pulsatile flow conditions.

Mesh:

Year:  2016        PMID: 27109010     DOI: 10.1115/1.4033474

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Fouling of mammalian hair fibres exposed to a titanium dioxide colloidal suspension.

Authors:  Milos Krsmanovic; Hessein Ali; Dipankar Biswas; Ranajay Ghosh; Andrew K Dickerson
Journal:  J R Soc Interface       Date:  2022-04-13       Impact factor: 4.118

2.  Mechanical Response Changes in Porcine Tricuspid Valve Anterior Leaflet Under Osmotic-Induced Swelling.

Authors:  Samuel D Salinas; Margaret M Clark; Rouzbeh Amini
Journal:  Bioengineering (Basel)       Date:  2019-08-15

3.  Characterizing Intracranial Hemodynamics in Sickle Cell Anemia: Impact of Patient-Specific Viscosity.

Authors:  Sara B Keller; Jacob M Bumpus; J Christopher Gatenby; Elizabeth Yang; Adetola A Kassim; Carlton Dampier; John C Gore; Amanda K W Buck
Journal:  Cardiovasc Eng Technol       Date:  2021-07-20       Impact factor: 2.305

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.