We read with interest the article by Olechowski, et al.[1] recently published in the Journal of Geriatric Cardiology. The results of this retrospective analysis of patients undergoing cardiac resynchronization therapy (CRT) device implantation are in line with previous reports, suggesting that resynchronization therapy in the elderly is feasible and may lead to significant improvement of cardiac function and clinical status. We think that the authors have provided very important data regarding safety of CRT device implantation in old patients. Thus, the total major complication rates were found equally distributed between the groups of patients > 80 and < 80 years old. However, pneumothorax was more frequently encountered in the older population. This complication is related to inadvertent lung injury by a needle during subclavian vein puncture, less frequently during axillary vein approach. Pneumothorax following pacemaker lead implantation is usually benign and managed by chest tube insertion with no further sequelae in otherwise healthy patients.[2] On the other hand, this complication might be devastating in very old patients with congestive heart failure, respiratory insufficiency, and other comorbidities. Although there is a number of publications describing clinical outcome of CRT in the elderly, data on periprocedural complications is surprisingly lacking. We have performed an extensive PubMed search with the following key words: CRT, CRT-D, implantable cardioverter-defibrillator (ICD), resynchronization, old, and elderly. This search yielded 3256 papers dealing with CRT/ICD implantation in patients > 65 years old. On a second step, non-age-comparative studies, studies not analyzing safety of device implantation in patients > 75 years old, review papers, editorials and case reports were excluded. This resulted in a selection of 26 papers. Of those, the reports on ICDs only, studies with insufficient data on complications were excluded. There was only one paper demonstrating prospective data combined from two randomized trials (MIRACLE and MIRACLE-ICD).[3] Regrettably, in a post-hoc analysis of safety in different age groups, the authors were unable to assess complications encountered during device implantation.[3] Therefore, only five retrospective reports were available for procedure-related safety assessment, including the study by Olechowski, et al.(Table 1).[1],[4]–[7] In four studies, the authors used 80 years as a cut-off value for delineation of the old population, and in one, 75 years. In each of these studies there was no statistically significant difference in total adverse event rates between older and younger groups. Of note, there was no difference in types of major complications between groups, except the report by Olechowski B. However, when pooled data from five reports were analyzed, there was a significant difference in the numbers of pneumothoraces between the older and younger patient groups.
Table 1.

Studies comparing the safety of CRT implantation in older and younger patients.

ReferenceAge cut-off, yrsNumber of younger patientsNumber of older patientsTotal early complications in younger patientsTotal early complications in older patientsPPneumothorax in younger patientsPneumothorax in older patientsP
Achilli A, et al., 2007[4]8010968548 (4.4%)2 (2.4%)> 0.05001
Verbrugge FH, et al., 2013[5]801714966 (3.5%)0> 0.051 (0.6%)0> 0.05
Killu O, et al., 2013[6]806389085 (13.3%)13 (14.4%)> 0.058 (1.3%)2 (2.2%)0.36
Höke U, et al., 2014[7]7559020831 (5.2%)12 (5.8%)> 0.053 (0.5%)2 (1.4%)0.158
Olechowski B, et al., 2015[1]8032411555 (17%)18 (16%)> 0.054 (1.2%)5 (4.3%)< 0.05
Total (all studies)Both 75 and 802819547284 (10.11%)45 (8.23%)> 0.0516 (0.57%)9 (1.65%)0.027
*Total (> 80 years old only)80 only2229339254 (11.40%)33 (9.73%)> 0.0513 (0.58%)7 (2.06%)0.022

Percentages taken from different totals were compared as weighted averages. *Only four studies included, where patients > 80 years are considered old.

Importantly, none of the reports included a detailed description of CRT device implantation technique. Therefore, we are unaware about the number and types of veins per patient used for primary CRT implantations and device upgrade procedures. Several techniques have been proposed to lower the risk of pneumothorax during venous access for cardiac rhythm device implantation: ultrasound visualization of the subclavian vein,[8] axillary vein puncture instead of the subclavian vein,[9] cephalic vein as a sole access for all leads.[10] It is anticipated that when the older patient is operated, the lesser the probability of reoperation in the future. Therefore, introducing of up to three leads over one small vein in an old patient should not be feared by operators. We suggest that in the older population only cephalic vein should be used for all leads, whenever possible. This simple change of approach might dramatically decrease the risk of pneumothorax during primary implantation, since no subclavian/axillary vein puncture is required. Moreover, this will allow preserving other routes for further possible interventions. Percentages taken from different totals were compared as weighted averages. *Only four studies included, where patients > 80 years are considered old. It is suggested that pneumothorax after CRT device implantation develops more frequently in older patients. Techniques, minimizing subclavian puncture, should be adopted by operators, and a sole cephalic vein access might be a reasonable approach in the elderly. We thank Mikhaylov and Lebedev for their detailed comments. They suggest that cephalic approach should be used for all 3 leads at implant, thereby minimizing the risk of pneumothorax during CRT device implantation in the elderly. We found that pneumothorax complicated procedures more frequently in those aged > 80 years old. It should be noted that in our series, 22% of procedures were upgrades, which is associated with higher risk of complications. In such procedures it is common for the cephalic vein to have been tied and used for previous lead access (cannot be used again). We do not have data as to the venous access approach for the procedures, but agree that careful planning for complex cases is crucial. Where possible the cephalic vein should be use, but in our experience it does not always permit access for 3 leads. A venogram visualizing the local venous anatomy accurately can be helpful and we would argue almost essential for patients undergoing upgrades.
  10 in total

1.  Safety and feasibility of cephalic venous access for cardiac resynchronization device implantation.

Authors:  Bassey Ussen; Paramdeep S Dhillon; Lisa Anderson; Ian Beeton; Mike Hickman; Mark M Gallagher
Journal:  Pacing Clin Electrophysiol       Date:  2010-11-22       Impact factor: 1.976

2.  Axillary vein puncture using fluoroscopic landmarks: a safe and effective approach for implantable cardioverter defibrillator leads.

Authors:  Federico Migliore; Mariachiara Siciliano; Manuel De Lazzari; Sonia Ferretto; Chiara Dalla Valle; Alessandro Zorzi; Domenico Corrado; Sabino Iliceto; Emanuele Bertaglia
Journal:  J Interv Card Electrophysiol       Date:  2015-05-09       Impact factor: 1.900

3.  Efficacy of cardiac resynchronization therapy in very old patients: the Insync/Insync ICD Italian Registry.

Authors:  Augusto Achilli; Federico Turreni; Maurizio Gasparini; Maurizio Lunati; Massimo Sassara; Massimo Santini; Maurizio Landolina; Luigi Padeletti; Andrea Puglisi; Mario Bocchiardo; Serafino Orazi; Giovanni Battista Perego; Sergio Valsecchi; Alessandra Denaro
Journal:  Europace       Date:  2007-07-18       Impact factor: 5.214

4.  Outcomes of cardiac resynchronization therapy in the elderly.

Authors:  Ammar M Killu; Jia-Hui Wu; Paul A Friedman; Win-Kuang Shen; Tracy L Webster; Kelly L Brooke; David O Hodge; Heather J Wiste; Yong-Mei Cha
Journal:  Pacing Clin Electrophysiol       Date:  2012-12-18       Impact factor: 1.976

Review 5.  Ultrasound-guided venous access for pacemakers and defibrillators.

Authors:  Arnold H Seto; Aaron Jolly; Jonathan Salcedo
Journal:  J Cardiovasc Electrophysiol       Date:  2012-11-06

6.  Left ventricular reverse remodeling, device-related adverse events, and long-term outcome after cardiac resynchronization therapy in the elderly.

Authors:  Ulas Höke; Hein Putter; Enno T Van Der Velde; Martin J Schalij; Victoria Delgado; Jeroen J Bax; Nina Ajmone Marsan
Journal:  Circ Cardiovasc Qual Outcomes       Date:  2014-05-13

7.  Response to cardiac resynchronization therapy in elderly patients (≥70 years) and octogenarians.

Authors:  Frederik H Verbrugge; Matthias Dupont; Philippe De Vusser; Maximo Rivero-Ayerza; Hugo Van Herendael; Jan Vercammen; Linda Jacobs; David Verhaert; Pieter Vandervoort; W H Wilson Tang; Wilfried Mullens
Journal:  Eur J Heart Fail       Date:  2012-09-20       Impact factor: 15.534

8.  Benefit of cardiac resynchronization in elderly patients: results from the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) and Multicenter InSync ICD Randomized Clinical Evaluation (MIRACLE-ICD) trials.

Authors:  Jordana Kron; Juan M Aranda; William M Miles; Thomas A Burkart; Gregory W Woo; Sherry J Saxonhouse; Samuel F Sears; Jamie B Conti
Journal:  J Interv Card Electrophysiol       Date:  2009-01-19       Impact factor: 1.900

Review 9.  Pacemaker implantation in small hospitals: complication rates comparable to larger centres.

Authors:  Bjørn Haug; Kjærsti Kjelsberg; Knut Tore Lappegård
Journal:  Europace       Date:  2011-06-28       Impact factor: 5.214

10.  Is cardiac resynchronisation therapy feasible, safe and beneficial in the very elderly?

Authors:  Bartosz Olechowski; Rebecca Sands; Donah Zachariah; Neil P Andrews; Richard Balasubramaniam; Mark Sopher; John Paisey; Paul R Kalra
Journal:  J Geriatr Cardiol       Date:  2015-09       Impact factor: 3.327

  10 in total
  1 in total

Review 1.  Sex, Race, and Age Differences of Cardiovascular Outcomes in Cardiac Resynchronization Therapy RCTs: A Systematic Review and Meta-analysis.

Authors:  Bradley McKay; Nicholas W H Tseng; Hassan I Sheikh; Mohammad K Syed; Maureen Pakosh; Jessica E Caterini; Abhinav Sharma; Tracey J F Colella; Kaja M Konieczny; Kim A Connelly; Michelle M Graham; Michael McDonald; Laura Banks; Varinder Kaur Randhawa
Journal:  CJC Open       Date:  2021-09-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.